PLANT DRAINS SYSTEM Flashcards

1
Q

Limiting temperature in the effluent of the blowdown tanks is important because _________________. (Ref. 2.2 BB SD)

A

hot water drains can damage sanitary sewer system concrete

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The _______________ provide a volume for hot discharge and drain flows to dissipate their energy. (Ref. 2.4.1 BB SD)

A

blowdown tanks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Blowdown Tank BB-TNK21 receives steam drains from __________________. (Ref. 2.4.3 BB SD)

A

main steam line drains

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Cooling for Blowdown Tank BB-TNK21 is supplied from __________________. (Ref. 3.0 BB SD)

A

the City Water System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The Plant Drain System on Unit 2 shuts down automatically when ___________ and the HRSGs are no longer generating steam. (Ref. 4.4 BB SD)

A

the respective combustion turbine is secured

How well did you know this?
1
Not at all
2
3
4
5
Perfectly