CONDENSATE AND FEEDWATER SYSTEM Flashcards
The ________________ provide(s) makeup water to the vacuum pumps, hotwell fill water, and the full amount of makeup water required by the HRSGs. (Ref: 3.2.1 CF SD)
condensate pumps
Each condensate pump is equipped with a minimum flow line to protect against overheating at times of low flow to the deaerator. The minimum flow lines feed into a common header which flows to the ___________________. (Ref: 3.2.2 CF SD)
condensate storage tanks
The deaerator removes air and non-condensable gases by using ______________.
steam entrainment
Feedwater flows from the deaerator and boiler feedwater pumps and then, in order, through a __________. (Ref: 3.4.3 CF SD)
flow indicating transmitter, flow control valve, economizer, then steam drum
Pressure in the deaerator is controlled at approximately 5 or 6 psig by ___________. (Ref: 4.0 CF SD)
controlling the amount of steam supplied