Dejardin, Vet Surg, 2018:
Minimally invasive lag screw fixation of SI luxation/fracture using the Sacroiliac Luxation Instrument System (SILIS)
What was the dorsoventral and craniocaudal screw deviation from an ideal trajectory?
Dejardin, Vet Surg, 2018:
0.9-3.8 degrees deviation from ideal trajectory
Pratesi, VCOT, 2018:
Bilateral SI luxation
How was SI reduction and stabilization achieved?
Pratesi, VCOT, 2018:
Use of a single 2.7mm cortical self-tapping transsacral screw and nylon nut
Schmierer, Vet Surg, 2019:
Feline ilial fractures - single locking plate vs single non-locking plate vs double non-locking plate
Which implants withstood more cycles?
Screw loosening occurred in which constructs?
Which constructs were superior?
Schmierer, Vet Surg, 2019:
Locking implants withstood more cycles
Screw loosening occurred only in the non-locking constructs
Single locking constructs were superior to single non-locking constructs, but double non-locking constructs offered a strong alternative
Guthrie
TPLO plate for ilial body fx
JSAP 2018
Reduction in pelvic canal diameter 5%
Bourbos
Skeletal Traction for Pelvic Fx
VCOT 2021
Relationship b/w weight and traction of 2 cm
~Transverse linear
~Oblique square of body weight
Jones
Influence of radiograph position on SI and LS angle
VCOT 2018
More than 5 degrees of malposition
~decreases SI and LS angles
Moving focal point to the femur
~decreased the measured lumbosacral angle
Abdominally centered radiographs
~no effect on lumbosacral and sacroiliac angles