Coxofemoral Joint Flashcards

1
Q

Kraska and Jackson, Vet Surg, 2018:
Hip toggle stabilization
Failure rate?
Most common method of failure?
Which construct withstood the greatest load to failure?

A

Kraska and Jackson, Vet Surg, 2018:
83% failure rate
Suture breakage at the toggle-suture interface was the most common method of failure due to friction and fraying
The construct with OrthoFiber #5 (braided UHMWPE suture) passed straight through the toggle rod eyelet withstood the greatest load to failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Helmick, VCOT, 2018:
Hip toggle stabilization
What % of hips had cartilage damage when the acetabulum was drilled via the femoral tunnel vs drilled independently?

A

Helmick, VCOT, 2018:
Cartilage damaged occurred in 38% of the hips in which the acetabulum was drilled via the femoral tunnel, and 0% of the hips in which the acetabulum was drilled independently

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Schlag, JAVMA, 2019:
Closed reduction and Ehmer sling application
Reluxation rate?
What % developed soft tissue injuries secondary to sling use?
Success rate?
Complication rate?

A

Schlag, JAVMA, 2019:
44% reluxation rate
50% developed soft tissue injuries secondary to sling use
Low success rate
High complication rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly