P's, C's, & T's Flashcards

1
Q

P-4

A

Rx Trip Permissive

Rx Trip and Bypass Breakers Open

  • Trips Main Turbine
  • FWIS w/ Low Tavg (564°F)
  • Prevents re-actuation of SI after Reset
  • Transfers CSDs from Load Reject to Plant Trip
  • Arms Steam Dumps
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

P-6

A

Source Range Permissive

IR > 10-10 Amps (1/2)

  • Permits Block of SR Trip
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

P-7

A

At-Power Permissive

P-10 or P-13 (1/2)

  • Unblocks the following trips:
    • PZR High Level
    • PZR Low Pressure
    • Low Flow in > 1 Loop
    • RCP UV
    • RCP UF
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

P-8

A

3 Loop Flow Permissive

PR > 48% (2/4)

  • Unblocks Low Flow in 1 Loop Trip
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

P-9

A

Turbine Trip - Rx Trip

PR > 50% (2/4)

  • Unblocks Rx Trip on Turbine Trip
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

P-10

A

Nuclear at Power

PR > 10% (2/4)

  • Feeds P-7
  • Blocks SR HV
  • Permits Block of:
    • IR Trip
    • IR Rod Stop
    • PR Low Setpoint Trip
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

P-11

A

Pressure SI

< 1970 psig (2/3)

  • Permits block of:
    • Low Pressure SI
    • Low Steam Pressure SI/SLIS
      • Enables SLIS on Hi Negative Pstm Rate
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

P-12

A

Low-Low Tavg

550°F (2/4)

  • Blocks steam dumps (CSDs)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

P-13

A

Turbine at Power

Pimp > 10% (1/2)

  • Feeds P-7
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

P-14

A

S/G High Level

SG Level > 91% (2/4 LTs on 1/4 S/Gs)

  • Trips MFPs
  • Trips Main Turbine
  • FWIS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

All Rx Trips

  • Trips
  • Setpoints
  • Coincidence/Interlocks
  • Protection
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

C-1

A

IR Rod Stop

20% PR Equivalent (IR Amps) - 1/2 IR channels

  • Stops outward rod motion
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

C-2

A

PR Rod Stop

103% - 1/4 PR (Can Be Bypassed)

  • Stops outward rod motion
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

C-3

A

OTΔT Rod Stop & Runback

OTΔT Trip - 2%: 2/4

  • Stops outward rod motion & causes turbine runback
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

C-4

A

OPΔT Rod Stop & Runback

OPΔT Trip - 2% on 2/4

  • Stops outward rod motion and causes turbine runback
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

C-5

A

Low Power Interlock

15% Power by Pimp

  • Auto Rod Withdrawal disabled.
17
Q

C-7

A

Loss of Load

10% Step or 5%/min decrease in Pimp

  • Manually Reset (PT-506 Only)
  • Arms steam dumps in Tave Mode
18
Q

C-9

A

Condenser Interlock

Cond. Pressure < 6.0” HgA (2/2 per shell, there is one C-9 for each condenser)

  • Condenser available for CSDs.
19
Q

C-11

A

Control Bank ‘D’ Rod Withdrawal Limit

223 Steps

  • Auto Rod Withdrawal disabled
20
Q

C-20

A

AMSAC

Pimp > 40% on 2/2 (505 & 506)

  • Arms AMSAC