One-Family Dwellings, Specific provisions Flashcards

1
Q

The maximum distance between kitchen countertop receptacles is _______?

A

4 feet
210.52(C)(1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Hanging luminaire located directly above any part of the bathtub shall be installed so that the luminaire is not less than ________feet above the top of the bathtub rim.

A

8 feet
410.10(D)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A 15-ampere rated duplex receptacle may be installed on a ________ branch circuit.

A

15 or 20 ampere
Table 210.21(B)(2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The minimum size THHN copper neutral conductor permitted for an 8 3/4 kW, 240 volt, 3 wire household electric range is???????

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Luminaires shall be constructed or installed so that adjacent combustible material will not be subjected to temperatures in excess of _________ degrees?

A

194 Degrees Fahrenheit.
410.11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A one-family dwelling has a front entrance on the east side of the house, an attached garage with two 10 foot wide doors on the south side, and a back entrance door on the west side of the house. This one-family dwelling requires _________ lighting outlet(s) for these outdoor entrances.

A

2
210.70(A)(2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Overcurrent devices shall not be located in the vicinity of easily ignitable material such as in _________.

A

Clothes closets
240.24(D)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A single receptacle installed on a individual branch circuit shall have an ampere rating not less than ________ percent of the rating of the branch circuit.

A

100 percent
210.21(B)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Appliance receptacle outlets installed for specific appliances, such as laundry equipment, shall be placed within ________ feet of the intended location of the appliance.

A

6 feet
210.50(C)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Tap conductors for household cooking equipment supplied from a 50-ampere branch circuit shall have an ampacity of not less than _________ Amperes.

A

20 Amps
210.19(A)(3) Exp #1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The rating of a single cord and plug connected utilization equipment shall not exceed _________ percent of the branch circuit.

A

80 percent
210.23(A)(1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A recessed incandescent luminaire with a completely enclosed light source installed in the ceiling of a cloths closet must have a minimum clearance of ________ inches between the luminaire and the nearest point of the closet storage space.

A

6 inches
410.16(C)(1)

Because it is in the wall not on

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where the NEC specifies that one equipment shall be “within sight of” another equipment, the specified equipment shall be visible and not more than ________ feet distant from the other.

A

50 feet
Article 100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

In a dwelling unit, a hallway measuring 21.5 feet in length requires a minimum of __________ receptacle outlets.

A

3
210.52(A)(1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A permanently connected dishwasher has a nameplate rating of 780 volt-amperes. The circuit breaker is permitted to serve as a disconnecting means where it is

A

Within sight from the dishwasher.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Interior stairway lighting outlets shall be controlled by a wall switch at each floor level, where the difference between levels s _________ steps or more.

A

6 risers (steps)
210.70(A)(2)(3)

17
Q

Supplementary overcurrent devices shall not be required to be _________.

A

Readily Accessible
240.10

18
Q

The maximum length cord permitted on a built-in dishwasher is ______..

A

6 feet 6 inches
422.16(B)(2)(3)

19
Q

A refrigerator receptacle can be fed from a __________?

A

15 ampere
210.52(B)(1) Exp. #2

20
Q

A receptacle installed in an area designated for the installation of laundry equipment and where there are no other receptacles can be a_______?

A

20 ampere
210.11(C)(2)

21
Q

At least one GFCI-protected receptacle shall be located within ________ feet from the outside edge of each bathroom sink.

A

6 feet
210.8.(A)(7)
Note. This is really 3 feet

22
Q

Receptacles are permitted under an overhanging countertop, but are not counted as required countertop receptacles, where the countertop extends more than _________ inches beyond its support base.

A

6 inches
210.52(C)(5) Exp.

23
Q

A branch circuit that provides power to a bathroom receptacle may also provide power to?

A

To other receptacles in other bathroom.
To lighting and equipment in same bathroom.
210.11(C)(3)

24
Q

At least one 120-volt, _________ ampere branch circuit shall be installed to supply receptacle outlets in attached garages and in detached garages with electric power.

A

20 Ampere
210.11(C)(4)