One-Family Dwellings, Specific provisions Flashcards
The maximum distance between kitchen countertop receptacles is _______?
4 feet
210.52(C)(1)
Hanging luminaire located directly above any part of the bathtub shall be installed so that the luminaire is not less than ________feet above the top of the bathtub rim.
8 feet
410.10(D)
A 15-ampere rated duplex receptacle may be installed on a ________ branch circuit.
15 or 20 ampere
Table 210.21(B)(2)
The minimum size THHN copper neutral conductor permitted for an 8 3/4 kW, 240 volt, 3 wire household electric range is???????
Luminaires shall be constructed or installed so that adjacent combustible material will not be subjected to temperatures in excess of _________ degrees?
194 Degrees Fahrenheit.
410.11
A one-family dwelling has a front entrance on the east side of the house, an attached garage with two 10 foot wide doors on the south side, and a back entrance door on the west side of the house. This one-family dwelling requires _________ lighting outlet(s) for these outdoor entrances.
2
210.70(A)(2)
Overcurrent devices shall not be located in the vicinity of easily ignitable material such as in _________.
Clothes closets
240.24(D)
A single receptacle installed on a individual branch circuit shall have an ampere rating not less than ________ percent of the rating of the branch circuit.
100 percent
210.21(B)
Appliance receptacle outlets installed for specific appliances, such as laundry equipment, shall be placed within ________ feet of the intended location of the appliance.
6 feet
210.50(C)
Tap conductors for household cooking equipment supplied from a 50-ampere branch circuit shall have an ampacity of not less than _________ Amperes.
20 Amps
210.19(A)(3) Exp #1
The rating of a single cord and plug connected utilization equipment shall not exceed _________ percent of the branch circuit.
80 percent
210.23(A)(1)
A recessed incandescent luminaire with a completely enclosed light source installed in the ceiling of a cloths closet must have a minimum clearance of ________ inches between the luminaire and the nearest point of the closet storage space.
6 inches
410.16(C)(1)
Because it is in the wall not on
Where the NEC specifies that one equipment shall be “within sight of” another equipment, the specified equipment shall be visible and not more than ________ feet distant from the other.
50 feet
Article 100
In a dwelling unit, a hallway measuring 21.5 feet in length requires a minimum of __________ receptacle outlets.
3
210.52(A)(1)
A permanently connected dishwasher has a nameplate rating of 780 volt-amperes. The circuit breaker is permitted to serve as a disconnecting means where it is
Within sight from the dishwasher.