One-Family Dwellings Flashcards

1
Q

A duplex receptacle rated 20 amperes can be installed on what rated branch circuit?

A

20 ampere

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The continuity of a grounded conductor shall not be dependent on the device in _________?

A

Multiwire Branch circuits
300.13(b)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Receptacles located more than ________ feet above the floor are not counted in the required number of receptacles along the wall.

A

5 feet 6 inch
210.52

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

At -least ________ inch of free conductor, measured from the point in the box where it emerges from its raceway or cable sheath, shall be left at each outlet, junction, and switch point for splices or the connection of luminaires or devices.

A

6 inches
300.14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In non-metallic-sheathed cable, the equipment grounding conductor for 15-,20-, and 30-ampere branch circuit __________

A

A equipment ground of the same size conductor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Receptacles installed for the attachment of portable cords shall be rated at not less than 15 amperes, 125 volts, or _______ amperes, 250 volts, and shall be of type not suitable for use as lamp holders.

A

15
406.3(B)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A luminaire that weights more than 6 pounds or exceeds ________ inches in any dimension shall not be supported by the screw shell of a lamp holder.

A

16 inches
410.30(A)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A cord connector that is supported by a permanently installed cord pendant shall be considered?

A

Receptacle Outlet
210.50(A)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Grounding-type receptacles shall be installed only on circuits of the _________ and ________ for which they are rated, except as provided in Tables 210.21(B)(2) and (B)(3).

A

Voltage class and current
406.4(A)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Outlet boxes or outlet box systems used as the sole support of a ceiling-suspended fan shall be listed, shall be marked by their manufacturer as suitable for this purpose, and shall not support ceiling-suspended fans that weight more than ________ pounds.

A

70 pounds
314.27(C)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Receptacle outlets in or on floors shall not be counted as part of the required number of receptacle outlets unless located within ________ inches of the wall.

A

18 inches
210.52(A)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Luminaires shall be wired with conductors having insulation suitable for the environmental conditions _______, ________, and ________ to which the conductors will be subjected.

A

Current, voltage and temperature
410.52

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A luminaire that weighs more than _______ pounds shall be supported independently of the outlet box, unless the outlet box is listed and marked on the interior of the box to indicate the maximum weight the box shall be permitted to support.

A

50 pounds
314.27(A)(1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A duplex receptacle rated 15 amperes can be installed on a ________ ampere general purpose branch circuit.

A

15 or 20 ampere
Table 210.21(B)(2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A branch circuit that supplies only one utilization equipment is known as a ___________ branch circuit.

A

Individual
100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The maximum distance between receptacles in a one-family dwelling is?

A

12 feet

17
Q

A non grounding-type receptacle has been replaced with a new grounding-type duplex receptacle. The 15-ampere circuit breaker feeding the circuit has been replaced with a 15-ampere ground-fault circuit breaker. The new receptacle or its cover plate must be marked _________?

A

No equipment ground and GFCI protected
406.4(D)(2)(C)

18
Q

An outlet where one or more receptacles are installed is called a __________?

A

Receptacle Outlet
(100)

19
Q

What is the maximum distance that a receptacle wall box can be set back from the finished surface of a 1/4 inch wood paneling wall?

A

1/4 inch

20
Q

Are switch controlled receptacles permitted in Bedrooms?

A

No
(270.70)

21
Q

A _________ is a system or circuit conductor that is intentionally grounded.

A

Grounded Conductor
(100)

22
Q

Define Branch Circuit

A

The circuit conductors between the final overcurrent device protecting the circuit and the outlets.

23
Q

A single receptacle rated 50 amperes can be installed on a ______ -ampere individual branch circuit.

A

50 amperes

24
Q

In dwelling units, a duplex receptacle fed from a multiwire branch circuit must have _______________ as a means of disconnect.

A

One double-pole circuit breaker or two single-pole circuit breakers without identified handle ties.