One-Family Dwellings Flashcards
A duplex receptacle rated 20 amperes can be installed on what rated branch circuit?
20 ampere
The continuity of a grounded conductor shall not be dependent on the device in _________?
Multiwire Branch circuits
300.13(b)
Receptacles located more than ________ feet above the floor are not counted in the required number of receptacles along the wall.
5 feet 6 inch
210.52
At -least ________ inch of free conductor, measured from the point in the box where it emerges from its raceway or cable sheath, shall be left at each outlet, junction, and switch point for splices or the connection of luminaires or devices.
6 inches
300.14
In non-metallic-sheathed cable, the equipment grounding conductor for 15-,20-, and 30-ampere branch circuit __________
A equipment ground of the same size conductor.
Receptacles installed for the attachment of portable cords shall be rated at not less than 15 amperes, 125 volts, or _______ amperes, 250 volts, and shall be of type not suitable for use as lamp holders.
15
406.3(B)
A luminaire that weights more than 6 pounds or exceeds ________ inches in any dimension shall not be supported by the screw shell of a lamp holder.
16 inches
410.30(A)
A cord connector that is supported by a permanently installed cord pendant shall be considered?
Receptacle Outlet
210.50(A)
Grounding-type receptacles shall be installed only on circuits of the _________ and ________ for which they are rated, except as provided in Tables 210.21(B)(2) and (B)(3).
Voltage class and current
406.4(A)
Outlet boxes or outlet box systems used as the sole support of a ceiling-suspended fan shall be listed, shall be marked by their manufacturer as suitable for this purpose, and shall not support ceiling-suspended fans that weight more than ________ pounds.
70 pounds
314.27(C)
Receptacle outlets in or on floors shall not be counted as part of the required number of receptacle outlets unless located within ________ inches of the wall.
18 inches
210.52(A)
Luminaires shall be wired with conductors having insulation suitable for the environmental conditions _______, ________, and ________ to which the conductors will be subjected.
Current, voltage and temperature
410.52
A luminaire that weighs more than _______ pounds shall be supported independently of the outlet box, unless the outlet box is listed and marked on the interior of the box to indicate the maximum weight the box shall be permitted to support.
50 pounds
314.27(A)(1)
A duplex receptacle rated 15 amperes can be installed on a ________ ampere general purpose branch circuit.
15 or 20 ampere
Table 210.21(B)(2)
A branch circuit that supplies only one utilization equipment is known as a ___________ branch circuit.
Individual
100