N19 - Condensate Flashcards

1
Q

What’s the purpose of the condensate system?

A

De-aerates, heats, and pumps condensate from hotwell to feedwater system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What’s the purpose of the Condensate Booster pumps?

A

Raise condensate pressure and discharge to the Low pressure feedwater heaters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What’s the power supplies to the CBPs?

A

A,B - 13AD

C - 14AE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Describe the path of condensate through the condensate?

A

From LP to IP to HP, then back to the IP condenser hotwell for condensate pump suction.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What’s the purpose of the false bottom of the condenser?

A

Allow time for N^16 gamma to decay to keep dose rates low in turbine and to keep condensate heated for efficiency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the power supplies to the Condensate pumps?

A

A - 13AD

B,C - 14AE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What level is the hotwell maintained at?

A

50%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When will the make-up/reject valves open?

A

> 50% F520 and F521 reject open

< 50% F518 and F519 make-up open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where are the condensate pump suction and discharge valves operated from?

A

Suction - P177

Discharge - P680 (opens 2 seconds after pump start)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How does the condensate min/flow valve operate? (flow path)

A

Flows from downstream of condensate clean-up to LP condenser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the max flow for the condensate min/flow valve F504?

A

5 mlbm/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where are the condensate booster pump suction and discharge valves operated?

A

Suction - P176

Discharge - P680 (auto opens on pump start)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How does the min flow valve for condensate booster pumps operate?

A

Recircs from condensate discharge header to high pressure condenser. Allows for 1.4 mlbm/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What’s the purpose of the vacuum breakers?

A

Break vacuum in condenser when plant is shut down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How do the vacuum breakers eliminate the possibility of air leakage into condenser?

A

A column of water is used as a seal above the valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What order do the condensate and condensate booster pumps trip in?

A

Alphabetical order

17
Q

What are the condensate pump trips?

A
  • Small Dogs Hate People *

Suction valve not full open

Discharge valve full closed (15 sec TD)

Hotwell level low < 1’4” (2 out of 3 logic)

Pressure (suction low) 27.7” Hg (15 sec TD)

18
Q

What are the Condensate Booster pump trips?

A
  • Little Small Dogs Like People *

Low oil pressure < 3 psig for 15 sec (closes suction valve)

Suction valve not full open

Discharge valve full closed (15 sec TD)

Loss of all condensate pumps

Pressure suction low < 46 psig (15 sec TD for A, 40 sec TD for B and C)

19
Q

What’s the trip logic for the condensate booster pumps?

A

Normal LO LO-LO LO-LO-LO
alarm & trips @ trips @ 60 sec
light 15 min
1.4 mlbm/hr 1.3 1.2-2.1 < 1.0

20
Q

What’s the trip logic for the condensate pumps?

A

Normal LO LO-LO LO-LO-LO
alarm & trips @ 15 min Trips @ 90 min
light

2.5-2.2 2.2-1.3 1.2-2.1 < 1.0