Multi-Story operating procedures Flashcards
What is the primary consideration when locating the siamese connection in a building with sprinkler and/or standpipe systems?
Location of the fire
Example sentence: The siamese connection should be located in close proximity to the fire source.
What should be checked and monitored throughout an incident involving a fire alarm system?
Annunciator panel
Additional information: The annunciator panel provides information on the status of the fire alarm system.
When attacking a fire on upper floors of a building without a standpipe system, what additional equipment should be brought along with the High Rise Kit?
Rope
Example sentence: The rope is essential for high angle rescue operations in buildings without standpipe systems.
In buildings taller than 15 stories, what is a potential issue with Pressure Reducing Valves (PRV)?
Limited pressure at the standpipe hookup
Example sentence: PRVs may cause reduced pressure levels at standpipe connections in tall buildings.
What should be done if debris is found in the standpipe during an inspection?
Use a solid stream nozzle
Additional information: Using a solid stream nozzle can help clear debris from the standpipe.
Which ventilation method should NOT be used in a confined space due to the risk of Carbon Monoxide (CO)?
Gas-powered fans
Example sentence: Gas-powered fans can introduce CO into confined spaces, posing a danger to occupants.
What is the recommended action for fire extension in the attic?
Pull down the ceiling and use hand lines
Example sentence: Pulling down the ceiling allows for better access to the fire in the attic.
What should be done to the Heating, Ventilating and Air Conditioning (HVAC) system during a fire incident?
Shut it down
Additional information: Turning off the HVAC system helps prevent the spread of smoke and fire through the ductwork.
In the absence of a standpipe system, what should crews use to attack a fire on upper floors?
High Rise Kit with 3” hose
Example sentence: The High Rise Kit with a 3” hose is used for firefighting operations in buildings without standpipe systems.
What is the role of the Rescue Officer when assigned to patient care?
Set up medical rehab for firefighting personnel
Example sentence: The Rescue Officer ensures that medical rehab is established for firefighters involved in patient care.
What type of ventilation methods should be used
What is the primary consideration for ventilation in buildings with difficult and time-consuming design?
Use both horizontal and vertical ventilation methods
Example sentence: Complex building designs require the use of both horizontal and vertical ventilation techniques.
When should the building engineer be located during a fire incident?
At the beginning of the incident
Additional information: Having the building engineer present at the start of the incident helps in accessing building systems.
How should circuit breakers be managed during a fire involving electrical hazards?
Turn off all circuit breakers
Example sentence: Turning off all circuit breakers is crucial to prevent electrical hazards during firefighting operations.
During a multi-story fire, What should be considered by command when setting up stairwell support In regards to the elevators?
Whether elevators are operational.
p130
Additional information: The operational status of elevators impacts the need for and placement of stairwell support.
What is the maximum distance allowed between a standpipe hookup and the most remote portions of a sprinkled floor according to NFPA 14?
200 feet