MTLO Flashcards

1
Q

Turbine Lube Oil
Purpose

A

Provides clean and tempered oil for bearing lubrication and cooling during normal and
emergency conditions for the Main Turbine, Generator, and Exciter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Unless permission has been obtained from operations director what should you NOT do with coolers?

A

Do not swap coolers at POWER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Main Turbine Oil conditioner
(LO-L-1 or bowser)

A

Purify main turbine lube oil continuously by removing water and
particulate materials. Design standard requires 10% of oil system purified per
hour (10 hours to purify entire LO volume), which the Bowser exceeds
.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Main bowser exhauster
(LO-E-1)
Location, Power supply

A

Location: 305’ TB on top of bowser
Power supply: 1C TP MCC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

LO-T-3 Exhauster (LO-E-3)
Location, Power supply

A

Location: 305’ TB west side of main bowser
Power supply: 1C TP MCC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Motor Drive Suction Pump (LO-P-4)
Location, power supply

A

Location: 322’ TB inside oil reservoir
Power supply: 1A TP MCC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

motor Drive Suction Pump (LO-P-4)
Auto start/purpose

A

Auto start: when LO-P-10 suction pressure ≤10#
Purpose: Provides suction pressure of 30 psig for LO-P-10 during start up when main turbine speed <95% rated speed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Turning Gear Oil Pump
(LO-P-5)
Location, power supply

A

Location: inside the oil reservoir
Power supply: 1A ES MCC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Turning Gear Oil Pump
(LO-P-5)
Auto Start/Trip

A

Auto Start:** Auto starts ≤15# @ Bearings or <190 # @ LO-P-10 discharge**
Trips: 27/86 Lockout of AUTO Start on ES + UV (can be manually started)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Emergency Bearing Oil Pump
(LO-P-6)
Location/power supply

A

Location: 322’ TB inside oil reservoir
Power supply: 1C DC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Emergency Bearing Oil Pump
(LO-P-6)
Auto Start

A

Auto starts on <170# @ LO-P-10 discharge if LO-P-5 doesn’t have
discharge pressure OR LO-P-5 loses power (breaker OPENS, bus de-energized,
thermal overload)
.** LO-P-6 will continue to run until manually shut down.**

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Main Shaft Driven Oil Pump (LO-P-10 or MSOP)
Purpose

A

Driven at 3600 rpm from the main shaft to supply oil to discharge
header at 200-225 psig to provide bearing lube oil and drive booster pump LO-P-11 when Main Turbine >95% speed
. LO-P-10 requires 15-20# suction pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Turbine Driven Booster Pump (LO-P-11)
purpose

A

An oil turbine driven pump that supplies oil at a pressure of
approximately 35# to suction of LO-P-10 when turbine shaft speed > 95%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Turbine Driven Booster Pump (LO-P-11)
Inlet baffler valve purpose

A

Throttles inlet to LO-P-11 to regulates booster pump
discharge at 35# @ rated speed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Turbine Driven Booster Pump (LO-P-11)
bypass baffler valve purpose

A

Throttles excess flow to LO-P-11 turbine into a bypass line,
supplying bearing header oil @ 35 psig at bearings and 50# at pump discharge.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Lube oil transfer pump (LO-P-1)
Location, power supply

A

Location: 305’ TB between east stairwell and Condensate chem add tanks
Power supply: 1A TP MCC

17
Q

Main Turbine Oil Filter Pump (LO-P-2)
Location, power supply

A

Location: 305’ TB West side of main bowser
Power supply: 1C TP MCC

18
Q

High Pressure Lift Oil Pump (LO-P-7A/B/C/D/E/F/G/H/I/J)
Location/power supply

A

Location: 355’ TB West of Main Turbine (A – F in NW Corner, G-J in SW Corner)
Power Supply: 7A through 7F →1A ES MCC, 7G through 7J → 1B ES MCC

19
Q

High Pressure Lift Oil Pump (LO-P-7A/B/C/D/E/F/G/H/I/J)
Interlocks
Start permissive
trips

A

Interlocks: ALL pumps must be running OR bypassed to place TB on turning gear
Start Permissive: >5# Suction Pressure
Trips: Pump trips on <5# Suction Pressure, 27/86 Lockout on ES and UV

20
Q

Explain what happens based on Bearing header pressure
Normal to low (3 things)

A

25-35# = normal bearing header pressure
≤15# Bearing Header LO-P-10 Discharge = LO-P-5 auto starts
≤12# bearing/24# at sensor location = the turbine will trip

21
Q

Explain what happens with MSOP suction/discharge pressures from normal to low (3 things)

A

200-225# = normal bearing/LO-P-10 discharge pressure
<190# LO-P-10 Discharge= LO-P-5 Auto starts
<170# LO-P-10 Discharge = LO-P-6 Auto starts if LO-P-5 is not running

22
Q

L&P
When do you change filter bag on bowser to avoid filter bag overflow?

A

When oil head above filter element has risen to 6 inches as indicated by filter compartment gauge glass

23
Q

What lube oil cooler outlet temperature do you maintain and with what valve when turbine is at rated speed?

A

110-120F via SC-V-5A/B

24
Q

What lube oil cooler outlet temperature do you maintain and with what valve when turbine is on turning gear?

A

80-90F via SC-V-5A/B

25
Q

Lube Oil Fire Hazard Reduction
(3 things)

A
  • Pressurized piping near hot components have guard pipe (pipe in a
    pipe), which returns any leakage back to reservoir
  • Tanks have covers that rapidly relieve oil vapor/H2 explosion
  • Minimize leakage by only placing threaded connections inside guard
    pipes and minimal use of pipe joints
26
Q

Lube Oil Coolers (LO-C-2A/B)
Location, power supply

A

Location: 322 TB inside Main Lube Oil Reservoir LO-T-3
Power supply: SCCW cools oil before entering bearing header, and only one
cooler in service at a time. DO NOT SWAP COOLERS AT POWER unless
permission has been obtained from Operations Director

27
Q

SC-V-5A/B throttled manually to maintain what?

A

To maintain normal operating temperature between 110-120F and 80-90F during startup and shut down

28
Q

Oil too cold causes what?

A

Oil whip, vibration and possible shaft/bearing damage

29
Q

Oil too hot causes what?

A

Viscosity Breakdown (less heat removal and lubrication, may lead to shaft/bearing damage

30
Q

Less than what bearing header pressure will turbine trip, and how many logic signals does it take?

A

<12#, 2 out of 3 logic at LO-PS-1700 A/B/C

31
Q

What happens on a loss of 1D 4kv?

A

LO-P-6 starts and does NOT supply TB bearing oil. LO-P-6 cannot overcome LO-P-11 discharge pressure