MQF: Systems Flashcards
Operating procedures, techniques, ect., that may result in personal injury or loss of life if not carefully followed.
Warning
Operating procedures, techniques, ect., that may result in damage to equipment if not carefully followed.
Caution
An operating procedure, technique, ect., that is considered essential to emphasize.
Note
The word ___ indicates an acceptable or suggested means of accomplishment.
May
The words____ and ____ are used to indicate a mandatory requirement.
Shall; Will
The air refueling valve, located at_____ is _____ when the handle is in the horizontal position.
FS 508; closed
When the air refueling valve is in the near vertical position, the valve ____.
Is open
The Utility Hydraulic System has a ___ gallon reservoir.
4.3
The Booster Hydraulic System has a ___ gallon reservoir.
3.1
The Auxiliary Hydraulic System has a ___ gallon reservoir.
5.3
The Utility Hydraulic System supplies hydraulic pressure to the_____.
Wing flap hydraulic motor and portion of the flight control boost system, the main and nose landing gear hydraulic motors, and the main landing gear brakes and nose wheel steering.
Ensure ____ has been removed prior to ___.
CLTs; Cargo door operation
When operating the manual ramp control, ensure the ramp control valve rotary handle is rotated in a ____ Direction.
Clockwise
The ARM light on the ADS control panel will illuminate in-flight when the following conditions are met:
The Aux hydraulic pump is turned on the anchor line arms are stowed, both ADS arm latch handles are engaged, and CLT launch portals are powered or cargo door bypass switch is placed in BYPS.
The NOGO light located on the ramp and door control panel and ADS control panel will illuminate any time (ground and in-flight) the following conditions are met.
CLT launch portals are not powered and the bypass switch is in the off position, and one or both anchor line arms are not stowed.
During in-flight operation of the cargo ramp & door, to prevent damage to the uplocks and to eliminate the uncontrolled drop of the door, position switch to OPEN and hold for ____ to ____ seconds prior to positioning the switch to CLOSE.
two; three
With the pump switch set to ON the either the _____ are powered or the _______ are placed in the ______ position, the ARM light on the ADS control panel and ramp and door control panel illuminate.
CLT launch portals; bypass switch; BYPS
The ACP ( Audio Control Panel) located at FS 245 is paired with the ______ ACP in case of ACP failure.
Instructor Pilot’s
In emergency mode, all ACPs can communicate with each other on the emergency net, including the pilot, co-pilot, navigator, flight engineer,______, the MOP navigator, and CSO.
FWD Aerial Gunner
The airplane is equipped with a _______ Liquid Oxygen (LOX) system capable of maintaining oxygen supply for a minimum of _____ man- hours.
75 liter; 300 psi; 264
The LOX system uses diluter demand automatic pressure breathing regulators and operates at an indicated pressure of _______ psi in a static system under a no-flow condition. Under a continuous breathing condition the pressure_______.
270-455; should read 270-340 psi
Two oxygen shut off valves are mounted on the right side wall of the aircraft. One located at _________ and second located at _______.
FS 677 forward of the troop door; FS 417 forward of the right cheek rack
the oxygen manual shut-off valve located at ________ shuts off the oxygen supply prior to individual regulator distribution lines. ( all O2 regulators).
FS 677
The oxygen manual shut-off valve located at ______ provides oxygen from the aircraft supply to the q the regulators on the MOP.
FS 417
The liquid oxygen low level warning light mounted on the_________ will illuminate to indicate a low level ( approximately ________) remaining in the LOX system.
Co-pilot’s instrument panel; 7.5 liters
Re-charging of MA-1 portable oxygen units is accomplished at the normal system pressure of ____ psi through a filler valve and flexible hose.
300
During oxygen system check, the ability to breathe when the supply lever is in the OFF position may indicate a/an:
Faulty regulator