Reconstructed – Maximum allowed out-of-plumbness
1/100 height
653: 10.5.2.1
Corrosion – pH level that causes corrosion to increase
< 5.0 pH
651: 5.3.2.1.g
Corrosion – Chloride level where pitting on steel begins
10 ppm
651: 5.3.2.1.h
NDE - Weight used to check magnetic strength of an AC yoke
10 lb.
V: T-762.b
Grounding - Maximum electrical resistance permitted from tank to earth
25 ohm
575: 8.2.6
NDE – Min angle of eye-to-part to count as a Visual Exam
30 degrees
575: 9.2.1
577: 8.3.1.f
NDE - Weight used to check magnetic strength of a DC yoke
40 lb.
V: T-762.c
NDE – Min light intensity needed for General Viewing tank
15 ft-candle
575: 9.2.1
NDE – Min light intensity needed for viewing tank anomalies
50 ft-candle
575: 9.2.1
NDE – Min light intensity needed for visual per API 577
100 fc
577: 8.3.2.2.a
NDE - Minimum light intensity when performing nonfluorescent MT or PT exams
100 fc
V: T-676.3 &
T-777.1
Vac Box – Min light intensity when performing vacuum testing
100 fc
650: 8.6.7
NDE - Minimum black light intensity when performing fluorescent MT or PT exams
1000 μW/cm2
V: T-676.4.d &
T-777.2.d
Brittle – Shell stress when brittle fracture is NOT a concern
< 7000 psi
653: Fig 5.1
NDE - Hole size that must be visible in RT when using a holetype IQI
2T
V: Tbl-276