Miscellaneous Numbers Flashcards
Roofs - Maximum amount of primary seal that can be removed for repair while tank is still in service
1/4
653: 9.14.1
NDE - Minimum number of RT’s required on a circular shell replacement plate
1
653: 12.2.1.6.1
FFS – Current joint efficiency “E” in API 650
1.0
653: Table 4.2
FFS – Joint Efficiency “E” – Calculating tmin for an LTA, when LTA is away from rivets by > 6”
1.0
653: 4.3.4.1
FFS – Joint Efficiency “E” – Calculating tmin for an LTA, when LTA is away from weld by greater of: 1” or 2t
1.0
653: 4.3.3.1
“E” defined
Reconstruction - Number of sets of center punch marks located on top and bottom edges of each shell piece
2
653: 10.3.5.2
Weld Qualification - Number of tension tests to qualify a WPS
2
IX: QW451.1
Weld Qualification - Number of bend tests to qualify a welder or welding operator in welding positions 1G-4G
2
IX: QW452.1.a
NDE - Minimum # of exposures to RT 360o
of a weld using a double-wall technique, double-wall view (elliptical shot)
2
V: T-271.2.b.1
NDE - RT film Density Range - allowed for the weld & IQI when using a gamma ray source
2.0 – 4.0
V: T-282.1
NDE - Minimum # of exposures to RT 360 deg of a weld using a double-wall technique, single-wall view
3
V: T-271.2.a
Impact Test - Number of test bars required in each set of impact test specimens
3
650: 4.2.9.3
NDE - When using a shim under a hole-type IQI, the number of sides of the IQI that must be seen in the RT image
3
V: T-277.3
Hot Tap - Minimum number of UT readings around the circumference of a new hot tapped nozzle
4
653: 9.15.3.2
Weld Qualification - Number of bend tests to qualify a WPS
4
IX: QW451.1