Mi-TIC S Flashcards
Turn the camera on with a short press of
The green button
To turn the camera off, press and hold the green button
For two seconds
LFR will use four of the seven application modes. They are
1- Fire
2-Overhaul
3- size up
4- inspection
This mode is used for attack and rescue in large, fully developed fires.
Fire Mode
In Fire mode, colorization is added gradually at scene temperatures above
300 degrees
This mode is used for checking hot spots after the fire is out
Overhaul mode
In Overhaul mode, red colorization is added to the hottest
Regardless of absolute temperature
2 %
In overhaul mode, yellow colorization is added to the next hottest
5% of the scene
This mode is used to easily locate the fire from outside of the structure
Size Up
This mode features a limited dynamic range of 480 degrees so that yellow colorization comes in earlier at 180 degrees.
Size Up mode
This mode is used for predictive maintenance to check equipment and buildings to help prevent fire.
Inspection mode
This mode uses a white hot, full color scale expanded to cover the dynamic range of the scene
Inspection mode
The camera can measure scene temps between
-40 and 2000 degrees
If the temp is higher than the maximum, the display will show
2200+F
The Argus Mi TIC has three levels of sensitivity: high, low and
Extended low
High sensitivity Mode is used under normal operating conditions. The temp range for this mode is
-40 and 302 degrees
In Low Sensitivity mode A small green triangle will be displayed in the top left corner. The temp range for this mode is up to
750 degrees
A small green triangle will be displayed in the top left corner. The temp range for this mode is up to 2000 degrees
Extended Low Sensitivity mode
Videos have a max length of
10 minutes or 100 MB
The compass should be used as
An aid only.
The camera will represent zones of very high temperatures as what colors
White or red
It is not possible for the operator to use the camera to look through
A window
The lens may be cleaned with
A glove or cloth
When the battery symbol starts to flash, the time remaining will typically be
10-15 minutes
If it is not in regular use, it should be switched on for a period of
Ten minutes every month
Batteries should be charged every
6 months
In Overhaul mode, where there is no significantly warmer area, no
Red or Yellow shows.