Edraulic Spreader Flashcards

1
Q

Hurst edraulic devices ARE NOT

A

Water proof or resistant.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Hurst edraulic devices are NOT

A

Explosion protected.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The rescue equipment should not come into contact with

A

Acids or alkalines. If unavoidable, clean with suitable agent.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

You can extend the operating time if your edraulic device by

A

Using several batteries.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

To open the device, turn the star grip in a ———— direction.

A

Clockwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Following release, the star grip automatically returns to the central position, fully guaranteeing load retention.

A

Dead man’s function

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The rechargeable battery will switch itself off after approximately

A

10-60 minutes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The following are to be worn when working with the rescue equipment:

A

Protective clothing
Helmet with visor or goggles
Gloves
Ear protection if necessary

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The highest force develops in the ————- of the plug- on tip.

A

Rear area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Squeezing is allowed in the area of the tips and

A

With the special squeezing plates in the arms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

It is possible to peel sheet steel with the optional peeling tips of the spreader. The spreader tip must be replaced with

A

The peeling tip.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Every —— or when there might be doubts regarding the safety or reliability of the the unit, an additional function test is to be carried out.

A

3 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Under normal working conditions routine oil changes are not necessary. After ———— an oil change is recommended.

A

10 years service life

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The air suction filter is to be checked at least

A

Once a year.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The LEDs attached on the —- light up the work area.

A

Operating side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Spreading:
Use the —- to increase an existing gap.

A

Front of the tips only

17
Q

Pulling:
—- must be used for pulling.
Must be checked by an expert at least once a year.

A

Hurst chain sets

18
Q

Never store with —-

A

Fully closed arms.

19
Q

The lock of the spreader plug on tips should be —- from time to time.

A

Greased

20
Q

A visual inspection must be carried out every—-

A

6 months.

21
Q

This inspection must be performed by a person with the necessary expertise. Must possess adequate specialist knowledge in the fields of electrical engineering and hydraulics.

A

Annual inspection

22
Q

The air suction filter is to be checked at least —-

A

Once a year or after use in a dusty environment. If filter is dirt, replace