Light (L03-L09) Flashcards
Each luminaire meets the following requirements for for regular use fixtures
(L04)
100% of light is emitted above the horizontal plane
Classified with Unified Glare Rating of 16 or lower
Luminance does not exceed 6,000 at angle angle between 45 and 90
Each luminaire meets one of the following requirements for regular occupied spaces
(L04)
Meets requirements in all spaces
Unified Glare Rating of 19 or lower
Daylight plan implemented (option 1 - 1(2) points)
L05
70% of workstations are within 25ft of glazing (Interior Layout)
or
Envelop glazing is no less than 15% of floor area (Façade)
VLT is greater than 40%
Daylight plan implemented (option 2 - 2(3) points)
L05
70% of workstations are within 16 ft of glazing (Interior Layout)
or
Envelop glazing is no less than 25% of floor area (Façade)
VLT is greater than 40%
A daylight plan is implemented in dwelling units -
L05
15% of dwelling unit (1 Point)
25% of dwelling unit (2 Points)
The following light levels are achieved for at least ____ hours at a height of ____ above the work plane.
(L03)
Four hours
18” above work plane
Meet daylight for active people 1(2) & 3(4)
L03
150 EML or 120 EML + L05 Part 1/L06 Part 1
240 EML or 180 EML + L05 Part 1/L06 Part 1
Lighting level requirements for dwelling units
L03
Dimmable and automatically dimmed after 8pm
Lighting levels are at a height of 55” in living rooms and kitchens
Daylighting is shaded by one of the following -
L05
Manual shading controllable at all times (opened once a day for all days)
Automated to prevent glare
Through computer simulations daylight stimulation is achieved for 1 (2) points -
(L06)
sDA300.50% is achieved for more than 55% of the floor area or 28fc is achieved for 50% of the unit for 50% of the daylit hours
Through computer simulations daylight stimulation is achieved for 1 (2) points -
(L06)
sDA300.50% is achieved for more than 75% of the floor area or 28fc is achieved for 50% of the unit and an average illuminance of 9fc is achieved for 95% of the dwelling unit for 50% of the daylit hours
Visual lighting is balanced through these 4 methods - (Option 1)
(L07)
Horizontal and vertical contrast ratios for an ambient lighting systems no more than 10 between adjacent spaces
Illuminance uniformity ration of at least .4 and 1:2:5 is achieved on a horizontal task plane
Automatic changes in lighting take place over a period of 10 mins
Correlated Color Temperature in each room is consistent (200K)
Visual lighting is designed by a professional and takes into account - (Option 2)
(L07)
Luminance ratios on horizontal and vertical adjacent zones
Illuminance uniformity of horizontal task planes
Changes in lighting characteristics
Color temperature
All luminaries meet one of the following color temperature requirements
(L08)
CRI > 90
CRI > 80 with R9 > 50
IES Rf > 78, Rg > 100, -1% < IES Rcs, hI 15%
All luminaries meet one of the following color temperature requirements for circulation areas -
(L08)
CRI > 80
IES Rf > 75, Rg > 95, -7% < IES Rcs, hI 15%