IFSTA: High-Rise Firefighting (12 Questions) Flashcards

1
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, products of combustion travel upward toward the top of a building. If fire does not generate enough heat to cause the smoke to rise to the top of the building, the temperature of the smoke will eventually equal that of the surrounding air. When this equalization of temperature occurs, the smoke loses its buoyancy, ceases to rise, and forms layers of smoke within the building. This is known as:

A

Stratification

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, the natural vertical movement of heat and smoke (convection) in tall structures is known as _______________. This occurs because of differences in the density of the air inside and outside of these buildings (due to temperature differences inside and outside the structure). The greater the difference between the inside and outside temperature and the greater the building height, the greater the effect will be.

A

Stack effect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, when heat, smoke, and other products of combustion rise until they encounter a horizontal obstruction, they will spread laterally until they encounter a vertical obstruction, then bank downward. This is known as __________________.

A

Ceiling jets, or mushrooming

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Rise Fire Fighting, the construction of high-rise
apartment buildings helps protect adjoining apartments and common halls, but provides an extremely hot environment for firefighters. Fires in tightly sealed high-rise compartments may become ventilation controlled and flash over when a window fails or when firefighters open a door to make entry to a fire room. This is known as ______________.

A

Heat intensity and compartmentation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, there are several other variables that involve wind, which of the following is not a relevant variable?

A

Barometric pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, firefighters must remember that steel structural members elongate when heated. A 50-foot (15 m) beam may elongate by as much as ___ inches (____ mm) when heated to a room temperature of about 1,000°F (538° C).

A

4 inches, 100 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

High-Rise Fire Fighting, which of the following about wind

driven fires is incorrect?

A

If windows in the fire area are intact, firefighters on attack lines do not need to maintain coordination with those tasked with ventilation from the floor above the fire or adjacent compartmented areas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, in a report published in 2009 by the National Institute of Standards and Technology (NIST), a number of full-scale experiments were conducted in a seven- story building in New York City. Which of the following were identified?

A

A) Wind conditions need to be considered in size-up; wind speeds of 10 to 20 mph are high enough to create wind-driven effects in buildings with an uncontrolled flow path
B) Controlling doors is a basic yet effective way to interrupt the flow path in a building. Care should be taken when opening stairwell doors leading to the fire floor. If after opening the door a few inches there are rapid changes in the volume or velocity of the smoke in the hallway, the door should quickly be closed
C) Positive-pressure ventilation fans always improved stairwell conditions, but were not able to reverse the direction of wind-driven fires. Positive-pressure ventilation was successful when used in conjunction with controlling doors, window control devices, and nozzles operated from the floor below the fire
D) All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Rise Fire Fighting, in a report published in 2009 by
the National Institute of Standards and Technology (NIST), a number of full-scale experiments were conducted in a seven- story building in New York City. Which of the following statements is incorrect?

A

Controlling doors is not effective way to interrupt the flow path in a building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, standpipe systems are divided into three classes based on NFPA 14, Standard for the Installation of Standpipes and Hose Systems. Which of the three classes are designed only for fire department personnel or other trained personnel?

A

Class I

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, a full evacuation of a high-rise structure may be deemed necessary, but it will be a labour-intensive and lengthy effort. Which of the following is not a best practice when fully evacuating a high rise?

A

A) Locking exit doors
B) Counterflow
C) Stairway exit capacity
D) All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, in other special high-rise occupancies, a person’s ability to evacuate may be hindered by age or medical condition. In hospital and nursing facilities, ___________________ procedures are generally used for patients who are nonambulatory.

A

Shelter in place

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, a strategic priority during high-rise operations will be gaining access to and monitoring building systems. Which of the following is a building system firefighters should control?

A

A) HVAC systems
B) Communications systems
C) Elevators
D) All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, the primary responsibility of the first-arriving company is to locate and identify the emergency and determine its scope. The first arriving fire unit must address the following except:

A

Utilize the Voice Communication System to update residents

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, for effective command, control, and relief of operating forces, it is essential that an IC be stationed at ground level. Some departments prefer a position on the exterior 200 feet (60 m) from the building. Which of the following is not a responsibility of the IC?

A

Use the Voice Communication System to update residents

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, firefighters have been injured or even killed as a result of misuse of elevators during a fire. Which of the following is not a safety consideration for using elevators at a high-rise call?

A

Only consider using elevators if the fire is above the 3rd floor

17
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, firefighters have been injured or even killed as a result of misuse of elevators during a fire. Which of the following is not a safety consideration for using elevators at a high-rise call?

A

Use elevators for occupant evacuation as soon as possible, even if fire is not under control

18
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, which of the following about winddriven fires in high-rises is correct?

A

Wind-driven fire conditions are unique to the top floors of high-rise buildings

19
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, which of the following is correct about breaking glass at a high-rise fire?

A

A) Breaking glass in high rise buildings can be a danger to firefighters inside the structure as well as firefighters and bystanders at ground level
B) Glass falling from a high-rise may land approximately 200 feet (66m) from the base of the building
C) After the window is broken, the area in front of the window (not the opening itself) should be blocked with a desk or chair to prevent firefighters from approaching the dangerous opening
D) All of the above

20
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, the situational report given periodically as needed throughout the incident to update Incident Command is known as a __________ report.

A

C.A.N. – Conditions, Actions, and Needs

21
Q

According to IFSTA’s Structural Fire Fighting: High-Rise Fire Fighting, use of plain English in radio communications transmissions. No 10-codes or agency specific codes are used when using this language:

A

Clear text

22
Q

Hamilton Fire Department Operational Guideline 0501.00, Incident Management/Incident Management System, under Establishment of Command, it states that “the unit assuming Command shall transmit a brief radio report including:

A

Identification of Unit on scene, confirm address of the incident, brief description of the incident, obvious conditions, any obvious safety concerns, and assume command.

23
Q

In Hamilton Fire Department Operational Guideline 0502.00, Incident Management/Incident Roles and
Responsibilities, states the role of ‘Captain’ is:

A

To act as the Incident Commander as required or operate at the assigned level under the direction of an Incident Commander.

24
Q

Hamilton Fire Department Operational Guideline 0621.00, Emergency Scene Operations/Fire Alarm Systems, under Private Residences (Smoke Alarm Systems) If a Smoke Alarm is sounding and no one answers the door, what actions shall the Incident Commander ensure are taken?

A

Ensure the perimeter has been checked for smoke/fire, check windows/doors have been checked for visual smoke/fire, if nothing found leave a 327 on the front door, if conditions warrant forcible entry police will be requested