According to the Fire Code, unless otherwise specified, the __________ is responsible for carrying out the provisions of this Code.

A

Owner

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

According to the Fire Code, ____________ means a device to convert fuel into energy, and includes all components, controls, wiring and piping required to be part of the device by the applicable standard referred to in this Code.

A

Appliance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

According to the Fire Code, which of the following is not correct about a Care Occupancy?

A

A Care Occupancy is the same as a retirement home under the Retirement Homes Act, 2010

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

According to the Fire Code, a _________ ___ fire means a fire involving combustible cooking media such as vegetable oils, animal oils and animal fats

A

Class K

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

According to the Fire Code, a _________ ___ fire means a fire involving a combustible metal

A

Class D

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

According to the Fire Code, a _________ ___ fire means a fire involving a flammable or combustible liquid, fat or grease

A

Class B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

According to the Fire Code, a _________ ___ fire means a fire involving energized electrical equipment

A

Class C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

According to the Fire Code, a _________ ___ fire means a fire involving combustible materials such as wood, cloth and paper

A

Class A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

According to the Fire Code, _______ __________ means a construction assembly that acts as a barrier against the spread of fire and may or may not have a fire-resistance rating or a fire-protection rating.

A

Fire Separation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

According to the Fire Code, _______ __________ means a draft-tight barrier within or between construction assemblies that acts to retard the passage of smoke and flame.

A

Fire Stop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

According to the Fire Code ______ ________ construction means that type of combustible construction in which a degree of fire safety is attained by placing limitations on the sizes of wood structural members and on thickness and composition of wood floors and roofs, by avoidance of concealed spaces under floors and roofs and by use of approved fastenings, construction details and adhesives for structural members.

A

Heavy Timber

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

According to the Fire Code ______ ________ means that type of construction in which a degree of fire safety is attained by the use of noncombustible materials for structural members and other building assemblies.

A

Noncombustible Construction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

According to the Fire Code, Subsection 2.8.2. Fire Safety Plans which of the following is incorrect. A fire safety plan shall provide for the emergency procedures to be followed in case of fire, including

A

Exhaust and fire protection systems required under Article 2.6.1.12. shall be maintained in accordance with NFPA 96, “Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

According to the Fire Code, Subsection 2.8.3.4. (1) and (2) a record shall be prepared of every fire drill, and the record shall be kept for at least ______ months.

A

12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

According to the Fire Code, Section 2.10, Day Care Centres, specifically 2.10.2. Combustible Materials; combustible artwork and teaching materials that are attached to walls shall not exceed _____% of the area of the walls.

A

20%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

According to the Fire Code, Section 2.13, Installing of Smoke Alarms, 2.13.1.2., despite the definition of owner in Article 1.4.1.2. in the case of a rental suite, only the __________ shall be considered to be the owner for the purposes of applying Article 1.2.1.1.

A

Landlord

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

According to the Fire Code, Section 2.13, Installing of Smoke Alarms, 2.13.2.1. (1) which of the following is incorrect regarding the installation of smoke alarms?

A

A smoke alarm shall be installed adjacent to a fuel fired appliance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

According to the Fire Code, Section 2.16, Installation of Carbon Monoxide Alarms, which of the following is incorrect? This Section applies to every building that contains a residential occupancy and:

A

A secondary suite

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

According to the Fire Code, Section 2.16 Installation of Carbon Monoxide Alarms, which of the following regarding installation requirements is correct?

A

A) A carbon monoxide alarm shall be battery-operated
B) A carbon monoxide alarm shall be permanently connected to an electrical circuit with no disconnect switch between the overcurrent device and the carbon monoxide alarm
C) A carbon monoxide alarm shall be plugged into an electrical receptacle
D) All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

According to the Fire Code, Part 3 Outdoor and Indoor Storage, Section 3.2.1. Outdoor Storage of Tires, individual storage piles of tires or shredded tires in a storage yard shall not be more than ____m in height and _____m2 in area.

A

3m in height and 100m2 in area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

According to the Fire Code, Part 3 Outdoor and Indoor Storage, Section 3.2.1. Outdoor Storage of Tires, which of the following is incorrect regarding pile locations and clearance?

A

Storage piles of tires or shredded tires in a storage yard shall be located at least 25 m from property lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

According to the Fire Code, Part 3 Outdoor and Indoor Storage, Section 3.3.2.10 (2), Pallet Storage, Indoor storage of combustible pallets is permitted in a building that is not sprinklered, provided the height of storage of combustible pallets is not more than ____ m.

A

1.2 m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

According to the Fire Code, Part IV Flammable Liquids and Combustible Liquids, 4.1.8.3 (1), which of the follow is incorrect regarding transfers of Flammable and Combustible Liquids?

A

Class I liquids shall be drawn from or transferred into containers or storage tanks within a building shall be transferred by means of pressure applied to a container or storage tank

24
Q

According to the Fire Code, Part IV Flammable Liquids and Combustible Liquids, Subsection 4.2.4 Assembly and Residential Occupancies, no more than ____ L of flammable liquids and combustible liquids, of which not more than 10L may be Class I liquids, may be stored in a dwelling unit, and no more than ____ L of flammable liquids and combustible liquids, of which not more than 30 L may be Class I liquids, shall be stored in a garage or shed attached to a dwelling unit.

A

30 L, 50 L

25
Q

According to the Fire Code, Section 5.6 Compressed Gas Cylinders, Subsection 5.6.1.5. temperature limitations; cylinders containing compressed gas shall be stored in areas where the ambient air temperature does not exceed _______ °C

A

52 °C

26
Q

According to the Fire Code, Section 5.6 Compressed Gas Cylinders, Subsection 5.6.2. Storage, which of the following is incorrect: Cylinders of flammable compressed gas which are heavier than air may be stored in rooms if they are stored:

A

The cylinders may be located in the basement or other areas below grade

27
Q

The cylinders are not located in the basement or other areas below grade According to the Fire Code, Part 6 Fire Protection Equipment, which of the following is correct about portable extinguisher locations?

A

A) In a detention occupancy, portable extinguishers are permitted to be located in secure areas, or in lockable cabinets
B) Portable extinguishers shall be located in or adjacent to corridors or aisles that provide access to exits
C) Portable extinguishers shall be located so that they are easily seen and shall be accessible at all times
D) All of the above

28
Q

According to the Fire Code, Part 6 Fire Protection Equipment, portable extinguishers with a gross weight greater than 18 kg shall be installed so that the top of the extinguisher is not more than ____ m above the floor when the extinguisher is not equipped with wheels.

A

1.1 m

29
Q

According to the Fire Code, Part 6 Fire Protection Equipment, portable extinguishers having a gross weight of 18 kg or less shall be installed so that the top of the extinguisher is not more than ____ m above the floor.

A

1.5 m

30
Q

According to the Fire Code, Part 6 Fire Protection Equipment, 6.2.6.2.,Building Protection; portable extinguishers that are provided to protect a building shall be suitable for fighting Class ____ fires and be available for use at all times.

A

Class A

31
Q

According to the Fire Code, Part 6 Fire Protection Equipment, 6.2.6.9. (3); Extinguishers for Flammable and Combustible Liquids, the distanced travelled to reach a portable extinguisher shall not exceed _____ m.

A

15 m

32
Q

According to the Fire Code, Part 6 Fire Protection Equipment, 6.2.6.16. (2); Extinguishers for Combustible Metal Fires, extinguishing equipment shall be located not more than ___ m from the Class D fire hazard.

A

25 m

33
Q

According to the Fire Code, Part 6 Fire Protection Equipment, Extinguishers for commercial cooking equipment, 6.2.6.12. (1); portable extinguishers for _______ ___ fires shall be provided to protect cooking operations.

A

Class K

34
Q

According to the Fire Code, Part 6 Fire Protection Equipment, Examination 6.2.7.2., portable extinguishers shall be ________ monthly.

A

Inspected

35
Q

According to the Fire Code, Part 6, Section 6.3 Alarm and Voice Communication Systems for Life Safety, Signal Silencing; once activated, a fire alarm system shall not be manually silenced unless it has been confirmed by _________ _________ in accordance with approved procedures as detailed in the fire safety plan, that no fire emergency exists

A

Supervisory Staff

36
Q

According to the Fire Code, Part 6, Section 6.3 Alarm and Voice Communication Systems for Life Safety, interconnected smoke alarms; where installed, each manual pull station shall be tested to ensure activation of the interconnected smoke alarms on a/an _________ basis.

A

Annual

37
Q

According to the Fire Code, Part 6, Section 6.3.3. smoke alarms – maintenance and testing; which is correct with regarding the duty to maintain in operating condition?

A

A) If the Building Code requires a visual signalling component that is integral with or connected to a smoke alarm, the visual signalling component shall be maintained in operating condition
B) Smoke alarms shall be maintained in operating condition
C) Primary and secondary power supplies that serve smoke alarms shall be maintained in operating condition
D) All of the above

38
Q

According to the Fire Code, Part 6, Section 6.4 Standpipe and Hose Systems; hose stations shall be inspected ___________ to ensure that the hose is in proper position and that all of the equipment is in place and in operable condition.

A

Monthly

39
Q

According to the Fire Code, Part 6, Subsection 6.5.3., sprinkler heads shall be ________ at least once per year to ensure that they are free from damage, corrosion, grease, dust, paint or whitewash

A

Checked

40
Q

According to the Fire Code, Part 6 Fire Protection Equipment, Subsection 6.5.6. Maintenance; where sprinkler systems are installed containing not more than 300 sprinklers, the minimum of pare sprinkler heads shall be:

A

6

41
Q

According to the Fire Code, Part 6 Fire Protection Equipment, Section 6.6 Water Supplies for Fire Protection; the water level in the fire pump reservoir shall be checked __________:

A

Weekly

42
Q

According to the Fire Code, Part 6 Fire Protection Equipment, Section 6.6 Water Supplies for Fire Protection; fire pumps shall be tested __________ at full rated capacity to ensure that they are capable of delivering the rated flow.

A

Annually

43
Q

According to the Fire Code, Part 6 Fire Protection Equipment, Section 6.7 Emergency Power Systems, the amount of fuel stored and connected to the emergency power system shall be sufficient to operate the engine for at least ____ hours.

A

2

44
Q

According to the Fire Code, Part 6 Fire Protection Equipment, Section 6.8 Special Fire Suppression Systems, which of the following NFPA standards is not applicable to the design and installation of a special fire suppression system that is not water-based?

A

NFPA 25 “Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems”

45
Q

According to the Fire Code, Part 7 Checking, Inspection, Testing, Notification and Maintenance of Fire Emergency Systems in High Buildings, every closure in an opening to the outdoors at the top of a smoke shaft shall be inspected __________.

A

Annually

46
Q

According to the Fire Code, Part 9 Retrofit, access to exits; number and location; where the occupant load of a room exceeds 60 persons, at least _____ egress doorway(s) shall be provided.

A

Two

47
Q

According to the Fire Code, Part 9 Retrofit, Subsection Means of Egress, emergency lighting; where sleeping accommodation is provided for more than ___ persons, emergency lighting shall be provided to corridors and stairways.

A

10

48
Q

According to the Fire Code, Part 9 Retrofit, Health Care Facilities, Fuel-fired appliance service rooms; fuelfired appliances shall be enclosed in a service room separated from the remainder of the building by a fire separation having a fire-resistance rating of not less than ______ minutes.

A

45

49
Q

According to the Fire Code, Part 9 Retrofit, Subsection 9.5.3 Means of Egress, emergency lighting; emergency lighting shall be provided in exit stairways, public corridors and other principal access to exits where the occupant load in a building exceeds ____ persons or there are more than 10 dwelling units.

A

24

50
Q

According to the Fire Code, Section 9.6, Buildings Higher than 6 Storeys in Building Height with Residential Occupancies, fire separations between occupancies; fire separations having a fire-resistance rating of not less than ____ _____ shall be provided between residential occupancies and other major occupancies.

A

1 hour

51
Q

According to the Fire Code, Section 9.6, Buildings Higher than 6 Storeys in Building Height with Residential Occupancies, Incinerator rooms, incinerator rooms shall be separated from the remainder of the building by a fire separation having a fire-resistance rating not less than ____ _____.

A

2 hours

52
Q

According to the Fire Code, Section 9.6, Buildings Higher than 6 Storeys in Building Height with Residential Occupancies, which is true about annunciator panels?

A

A) Be inspected and tested monthly
B) An annunciator panel shall indicate all floors with not more than one floor per zones indicated
C) Be located at the main street entrance to the building or a location that is accessible to the fire department and that is approved
D) Both B and C are correct

53
Q

According to the Fire Code, Section 9.6, Buildings Higher than 6 Storeys in Building Height with Residential Occupancies, hydrants shall be located within ____ metres of the building face on which the principle entrance is located.

A

90

54
Q

According to the Fire Code, Section 9.6, Buildings Higher than 6 Storeys in Building Height with Residential Occupancies, Firefighters’ elevators; At least one elevator shall be provided for use by firefighters in accordance with Articles 3.2.6.8. and 3.2.6.9. of the 1990 Building Code in buildings where the vertical distance between the floor of the top storey and grade exceeds ___ ______.

A

18 metres

55
Q

According to the Fire Code, Section 9.6, Buildings Higher than 6 Storeys in Building Height with Residential Occupancies, Subsection 9.9.5. Suppression; In buildings that are greater than ___ ______ in building height, a standpipe and hose system shall be installed in conformance with Subsection 3.2.9. of the 1994 Building Code.

A