Ice and rain protection Flashcards
ALPHA
ACW supply. AMBER LT
illuminates in case of FAIL or
power loss. CAP
TAT
no heated. CAP. (ACW supply)
heating inhibited on ground.
PITOT tube
not heated. CAP. (ACW bus
1 for CPT and ACW bus 2 for
F/O).
STAT
Static port not heated (On
ground only, not monitored in
flight). CAP. (DC BUS)
PITOT STBY
not heated.
ACW BUS 1 or 115 AC STBY
BUS as back up.
WINDSHIELD HTG
ACW supply. Outer surface
+2°C. Inner +21°C
WINDSHIELD HTG FAULT
Power loss or failure. CAP.
CAPT, STBY and F/O
Normal operation - ON
depressed) and OFF (released
WIPER rotary selector: OFF: SLOW: FAST:
wiper stops at the end of travel (park) position wiper operates at 80 cycles/min wiper operates at 130 cycles/min
Ice detector panel and
icing AOA - FAULT
FAULT
detector failure or supply loss (ACW
BUS 2). CAP.
Ice detector panel and
icing AOA - PTT pb
PTT pb press for 3’’: – icing will flash if system works correctly. – FAULT LT illuminates steady if ice detector failure is detected
Ice detector panel and
icing AOA - ICING AOA Lt illuminates green as soon as
- 1 horn anti-icing on.
- Stall alarm + stick shaker threshold lowered.
- When light ON, the angle of attack for the stall warning is reduced.
- It can be extinguished manually only by releasing ICING AOA P/B provided both horns anti-icing are selected OFF.
Ice detector panel and
icing AOA - ICE DET
ICE DET indicator Lt: ACW bus 2.
Ice detector panel and
icing AOA - ICING
illuminates amber when
Ice accretion is detected provided both horns anti-icing and airframe de-icing are selected ON.
Ice detector panel and icing AOA - ICING flashes amber when
Ice accretion is detected and horns anti-icing and/or
airframe de-icing are not selected ON