Air conditionning Flashcards
1
Q
Cooling of air:
A
– by two ground turbo fans:
• IAS ≤ 150 kt and ldg gear is retracted for less than 10 min
• IAS ≤ 150 kt and ldg gear is extended.
– by ram air when IAS >150 kt
2
Q
RECIRC FAN
A
Assists pack air flow
3
Q
RECIRC FAN - FAULT
A
Fan low speed or motor overheat + AIR on CAP. No auto disconnect
4
Q
COMPT INDICATOR
A
Duct temperature limited to
88°C. (191°F) by pneumatic
temp.limiter
5
Q
TEMP SEL
A
AUTO: the temperature is closed by the electronic temperature controller, taking into account: – duct temperature – zone temperature demand selector – associated compartment temperature – aircraft skin temperature
6
Q
TEMP SEL - OVHT
A
Duct overheat > 92 °C + AIR on CAP. Pack valve will not auto close
7
Q
MAN
A
Compt temp knob controls directly temp control valve
8
Q
FLOW
A
NORM: 22 psi (pack valves)
HIGH: 30 psi (pack valves)