Ice And Rain Protection Flashcards
What is normal de-ice system pressure?
18PSI
DE ICE PRESS
<5.5PSI. use ISO function to isolate the side thats leaking. Use Manual mode and exit icing.
What does the ISO function do?
splits the 1 and 2 systems to isolate the side with a leak
What flap setting must you use when holding in icing?
flap up (0deg)
What is the total inflation time of the wing anf tail boots?
6 sets x 6sec each = 36sec.
What is the cycle time of the SLOW airframe setting?
4mins
What is total cycle time of the FAST airframe setting?
1min
How long will the boot inflate for in manual mode
Still secs to inflate, but will stay inflated until switch is moved.
How would you know if a boot was not inflating?
No green indicator light (pressure switch at 15psi)
What should you do if a boot doesnt inflate?
consult QRH - check advisory lights and either continue if bulb is blown or if bulb functions, exit icing conditions. Max flap for LDG 15deg.
how many prop timers are there?
2
What is the power source for the prop heat?
115VAC
What are the durations for above -10deg and below -10deg settings? (prop heat)
above -10: on duration 10secs, rest 1min (70sec cycle)
below -10: on duration 20sec, rest 1 min (80sec cycle)
How would you know a prop heater was inop? QRH?
Light not on.
test the light (advisories) + swap timers, then C/L max + exit icing conditions or continue.
What are the power sources for the pitot heats?
L ess(1), R Main(2)