Ice and Rain Flashcards
WAI
• Bleed air, piccolo tubes
• Electrically controlled, pneumatically actuated pressure control valve
• Spring loaded closed
• 130F
• Cross-over duct – redundancy
• Under/over temp switch
• Inhibited from takeoff to 1500 RA and above 35k ft
• If AUTO ON below 35k ft, it will stay ON above 35k ft until ice no longer detected
• If AUTO ON, do not manually select to ON
• Does not heat wheel well
•
WAI
• Bleed air, piccolo tubes
• Electrically controlled, pneumatically actuated pressure control valve
• Spring loaded closed
• 130F
• Cross-over duct – redundancy
• Under/over temp switch
• Inhibited from takeoff to 1500 RA and above 35k ft
• If AUTO ON below 35k ft, it will stay ON above 35k ft until ice no longer detected
• If AUTO ON, do not manually select to ON
• Does not heat wheel well
•
Engine AI
• High press bleed, piccolo tubes
• Electrically controlled, pneumatically operated thermal AI (TAI) valve
• Fail open (Powered close)
•
- Pre-cooler – 450 degF (400 wihout AI)
* Single bleed – 500 degF limit to 26,000ft (extract too much bleed air affect engine performance)
•
Windshield heat
• Electrical heating film to Main windshield and side windows
• HI/LO selects heated area (does not change set temperature)
•
Probe AI • 3 x pitot • 2x AOA • 1 x TAT • 7 x static port (not heated) • AUTO – WOW switch • OVRD – ON on ground
•
Ice detect
• 0.02 inches of ice
• Once ice detected, latched for 60 secs
• Heater on to remove ice from detector
•
• Ice shedding (QRH NI)
- Icing Conditions - <10 SAT/TAT visible moisture
- Standing water = icing conditions (Engine AI ON)
- Freezing rain – climb, warm air above
- Freezing Fog (< 0 degC, 1000m) (NI)
- Windshield heat (100-110 degC)
- HI same temperature – heast 2nd wire grid, more concentrated
• Will it affect Type IV fluid? Not if < 20 mins
•
• Ice shedding (QRH NI)
- Icing Conditions - <10 SAT/TAT visible moisture
- Standing water = icing conditions (Engine AI ON)
- Freezing rain – climb, warm air above
- Freezing Fog (< 0 degC, 1000m) (NI)
- Windshield heat (100-110 degC)
- HI same temperature – heast 2nd wire grid, more concentrated
• Will it affect Type IV fluid? Not if < 20 mins
•
LIMITATIONS
• Use of WAI above +10 or below -40 not recommended
• Use of WAI above 26k ft on single bleed prohibited
• Do not operate WAI on TOGA unless already at 130 degF
• Probe heat OVRD on ground >30secs prohibited
• EAI required for taxi if <10degC and visible moisture
• Use of flaps in icing restricted to takeoff, approach and landing
• Holding in icing at flaps 0 only
•