APU Flashcards

1
Q

GENERAL

  • Model –
  • Approved for unattended ops – YES/NO
  • Fuel burn –
  • Fuel feed –
  • APU off and door closed for _____
  • Generator – __ VDC / __ AMP
  • Oil Quantity – __ US quarts
A

GENERAL

  • Model – Honeywell GTCP36-150
  • Approved for unattended ops – YES
  • Fuel Burn – 100-120 lbs/hr
  • Fuel feed – R STBY fuel pump or R engine driven pump
  • APU off and door closed for deicing
  • Generator – 28 VDC / 400AMP
  • Oil Quantity – 2 US quarts
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

ENVELOPE (LIMITATION)

  • Max altitude for start –
  • Max altitude for ops –
  • Max altitude for bleed air –
  • Max altitude for engine start –
  • Bleed Off TO up to ____ft AGL, MPRSOV open and “BLEED CONFIG”
A

ENVELOPE (LIMITATION)

  • Max altitude for start – 35,000ft
  • Max altitude for ops – 40,000ft
  • Max altitude for bleed air – 20,000ft
  • Max altitude for engine start – 15,000ft
  • Bleed Off TO up to 1,500ft AGL, MPRSOV open and “BLEED CONFIG”
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ESSENTIAL/NON-ESSENTIAL MODES

  • Fire – shutdown for ________ mode/s, _______ activation of fire extinguisher
  • Essential mode – WOW in ___ mode and until ___ mins after landing
  • APU Essential CAS – fault detected which normally causes APU to _____ if not in Essential Mode
  • APU STOP switch – trigger shutdown via ___ signal
  • APU Bleed ON – LCV and Isolation valve ___
A

ESSENTIAL/NON-ESSENTIAL MODES

  • Fire – shutdown for both essential and non-essential modes, manual activation of fire extinguisher
  • Essential mode – WOW in air mode and until 15 mins after landing
  • APU Essential CAS – fault detected which normally causes APU to shut down if not in Essential Mode
  • APU STOP switch – trigger shutdown via overspeed signal
  • APU Bleed ON – LCV and Isolation valve open
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

APU MASTER

  • BITE check
  • APU inlet door opens
  • APU Fuel shutoff valve opens
  • Cyan CAS “APU Ready” after ___ secs
A

APU MASTER

  • BITE check
  • APU inlet door opens
  • APU Fuel shutoff valve opens
  • Cyan CAS “APU Ready” after 25 secs
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

APU START

  • Fuel – ___ RPM
  • Starter drop out – ___ RPM
  • Ignition drop out – ___ RPM
  • Gen avail ___ RPM + ___ secs (shifts from starter motor to generator – reverse polarity)
  • Bleed avail ___ RPM + ___ secs (temperature stabilises, fuel flow doubles)
A

APU START

  • Fuel – 10% N1
  • Starter drop out – 50% N1
  • Ignition drop out – 95% N1
  • Gen avail 95% RPM + 4 secs (shifts from starter motor to generator – reverse polarity)
  • Bleed avail 95% RPM + 90 secs (temperature stabilises, fuel flow doubles)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

LIMITATION - START

  • __ mins between shutdown and next start
  • __ mins cooling after __ attempts
A

LIMITATION - START

  • 2 mins between shutdown and next start
  • 30 mins cooling after 3 attempts
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

LIMITATION

  • APU Gen load limit –
  • Max rotor speed –
A

LIMITATION

  • APU Gen load limit – 100%
  • Max rotor speed – 108%
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

LIMITATION - MAX EGT

  • Start < 50% - ___
  • Start 50% to 90% - ___ decreasing to ___ °C
  • Running – ___ °C
  • Bleed air in use – ___ °C
A

LIMITATION - MAX EGT

  • Start < 50% - 974 °C
  • Start 50% to 90% - 974 decreasing to 718 °C
  • Running – 718 °C
  • Bleed air in use – 666 °C
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

LIMITATION

  • Do not operate if Fire Bottle ___ activated
  • ___ fuel pump or ___ engine driven pump to operate
  • APU ___ and door ___ for deicing
A

LIMITATION

  • Do not operate if Fire Bottle #2 activated
  • R STBY fuel pump or R engine driven pump to operate
  • APU off and door closed for deicing
How well did you know this?
1
Not at all
2
3
4
5
Perfectly