APU Flashcards
1
Q
GENERAL
- Model –
- Approved for unattended ops – YES/NO
- Fuel burn –
- Fuel feed –
- APU off and door closed for _____
- Generator – __ VDC / __ AMP
- Oil Quantity – __ US quarts
A
GENERAL
- Model – Honeywell GTCP36-150
- Approved for unattended ops – YES
- Fuel Burn – 100-120 lbs/hr
- Fuel feed – R STBY fuel pump or R engine driven pump
- APU off and door closed for deicing
- Generator – 28 VDC / 400AMP
- Oil Quantity – 2 US quarts
2
Q
ENVELOPE (LIMITATION)
- Max altitude for start –
- Max altitude for ops –
- Max altitude for bleed air –
- Max altitude for engine start –
- Bleed Off TO up to ____ft AGL, MPRSOV open and “BLEED CONFIG”
A
ENVELOPE (LIMITATION)
- Max altitude for start – 35,000ft
- Max altitude for ops – 40,000ft
- Max altitude for bleed air – 20,000ft
- Max altitude for engine start – 15,000ft
- Bleed Off TO up to 1,500ft AGL, MPRSOV open and “BLEED CONFIG”
3
Q
ESSENTIAL/NON-ESSENTIAL MODES
- Fire – shutdown for ________ mode/s, _______ activation of fire extinguisher
- Essential mode – WOW in ___ mode and until ___ mins after landing
- APU Essential CAS – fault detected which normally causes APU to _____ if not in Essential Mode
- APU STOP switch – trigger shutdown via ___ signal
- APU Bleed ON – LCV and Isolation valve ___
A
ESSENTIAL/NON-ESSENTIAL MODES
- Fire – shutdown for both essential and non-essential modes, manual activation of fire extinguisher
- Essential mode – WOW in air mode and until 15 mins after landing
- APU Essential CAS – fault detected which normally causes APU to shut down if not in Essential Mode
- APU STOP switch – trigger shutdown via overspeed signal
- APU Bleed ON – LCV and Isolation valve open
4
Q
APU MASTER
- BITE check
- APU inlet door opens
- APU Fuel shutoff valve opens
- Cyan CAS “APU Ready” after ___ secs
A
APU MASTER
- BITE check
- APU inlet door opens
- APU Fuel shutoff valve opens
- Cyan CAS “APU Ready” after 25 secs
5
Q
APU START
- Fuel – ___ RPM
- Starter drop out – ___ RPM
- Ignition drop out – ___ RPM
- Gen avail ___ RPM + ___ secs (shifts from starter motor to generator – reverse polarity)
- Bleed avail ___ RPM + ___ secs (temperature stabilises, fuel flow doubles)
A
APU START
- Fuel – 10% N1
- Starter drop out – 50% N1
- Ignition drop out – 95% N1
- Gen avail 95% RPM + 4 secs (shifts from starter motor to generator – reverse polarity)
- Bleed avail 95% RPM + 90 secs (temperature stabilises, fuel flow doubles)
6
Q
LIMITATION - START
- __ mins between shutdown and next start
- __ mins cooling after __ attempts
A
LIMITATION - START
- 2 mins between shutdown and next start
- 30 mins cooling after 3 attempts
7
Q
LIMITATION
- APU Gen load limit –
- Max rotor speed –
A
LIMITATION
- APU Gen load limit – 100%
- Max rotor speed – 108%
8
Q
LIMITATION - MAX EGT
- Start < 50% - ___
- Start 50% to 90% - ___ decreasing to ___ °C
- Running – ___ °C
- Bleed air in use – ___ °C
A
LIMITATION - MAX EGT
- Start < 50% - 974 °C
- Start 50% to 90% - 974 decreasing to 718 °C
- Running – 718 °C
- Bleed air in use – 666 °C
9
Q
LIMITATION
- Do not operate if Fire Bottle ___ activated
- ___ fuel pump or ___ engine driven pump to operate
- APU ___ and door ___ for deicing
A
LIMITATION
- Do not operate if Fire Bottle #2 activated
- R STBY fuel pump or R engine driven pump to operate
- APU off and door closed for deicing