ECS Flashcards
AIR CYCLE MACHINE (ACM) • Single ACM • 3 sources of cabin flow and ventilation • \_\_\_\_ • \_\_\_\_ • \_\_\_\_
AIR CYCLE MACHINE (ACM) • Single ACM • 3 sources of cabin flow and ventilation • Normal • Alternate • Ram air intake
TEMPERATURE CONTROL
• AUTO – __ to __ degF
• MAN – __ to __ degF
• Cold air plenum regulated to __ degF (2 degC)
• Gaspers take air from ___ air plenum only
TEMPERATURE CONTROL
• AUTO – 60 to 90 degF
• MAN – 35 to 160 degF
• Cold air plenum regulated to 35 degF (2 degC)
• Gaspers take air from cold air plenum only
DISTRIBUTION
• Separate ducting for gasper air, cabin and flight compartment
• Gasper air only from cold plenum, also cools aft R equipment rack
• Flight compartment – defog and pilot/Copilot air conditioning
DISTRIBUTION
• Separate ducting for gasper air, cabin and flight compartment
• Gasper air only from cold plenum, also cools aft R equipment rack
• Flight compartment – defog and pilot/Copilot air conditioning
EQUIPMENT COOLING
• Nose bay – cooling fans (DIST BUS), ON when temp >___ degF (45 degC)
• CAS (cyan) – nose temp > __ degF (60 degC)
• CAS (Amber) – nose temp > __ degF for more than __ mins
EQUIPMENT COOLING
• Nose bay – cooling fans (DIST BUS), ON when temp >113 degF (45 degC)
• CAS (cyan) – nose temp > 140 degF (60 degC)
• CAS (Amber) – nose temp > 140 degF for more than 30 mins
ALTERNATE PRESSURIZATION
• Bypass ____
• Primary from ___ Eng bleed (downstream from pre-cooler)
• Cooled by ___ heat exchanger (air expected to be hot) NACA scoop above R pylon
• Controlled by ______
• Can use ___ Eng through isolation valve
ALTERNATE PRESSURIZATION
• Bypass ACM
• Primary from R Eng bleed (downstream from pre-cooler)
• Cooled by ram air heat exchanger (air expected to be hot) NACA scoop above R pylon
• Controlled by AAPRSOV
• Can use L Eng through isolation valve
RAM AIR
• Inlet scoop fwd base of _______
• Branch 1 - Primary and secondary ____ exchangers
• Branch 2 - Check valve at cold-air plenum, ventilation for low-altitude flights when primary and alternate pressurization not available
• Branch 3 - Ventilation for ____ and ____
RAM AIR
• Inlet scoop fwd base of vertical stabilizer
• Branch 1 - Primary and secondary heat exchangers
• Branch 2 - Check valve at cold-air plenum, ventilation for low-altitude flights when primary and alternate pressurization not available
• Branch 3 - Ventilation for aft fuselage and cabin
NOTES
• AMSC (Air Management System Controller) Right Aft avionics cabinet – controls BAS, WAI and ECS
• PACK switch DIFF light when cabin differential pressure > 9.55 psi
NOTES
• AMSC (Air Management System Controller) Right Aft avionics cabinet – controls BAS, WAI and ECS
• PACK switch DIFF light when cabin differential pressure > 9.55 psi
LIMITATIONS
• Hi flow on ground with ___ only
LIMITATIONS
• Hi flow on ground with APU only