Hydraulic System Flashcards

1
Q

Hydraulic System Pressure?

A

3000 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is normal reservoir quantity?

A

45% to 85%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If the reservoir is outside of its normal range, what color will the digital quantity be displayed in?

A

White

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What type of hydraulic fluid do we use?

A

Skydrol - Color purple

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

If pump 1a or 2a fails, will the respective electric pump activate automatically?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When will the electric pump (ACMP’s) automatically activate?

A

With their switches in auto, at least one generator online and flap position greater than zero.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How are hydraulic systems 1 and 2 cooled? How is hydraulic system 3 cooled?

A

Systems 1 and 2 are cooled by ram air in flight, and ram air duct fan on ground. Blows cool air over heat exchanger in aft equipment bay.

System 3 naturally cools

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If there is an engine driven pump failure, must the associated hydraulic pump be shut down?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When will hydraulic 1 or 2 HI TEMP caution be displayed?

A

When temps exceed 96’ celcius

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When a powered hydraulic system is displayed in white on the hydraulic synoptic page, what is indicated?

A

The system is pressurized above 1800 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is indicated when a system is displayed in amber?

A

The system is pressurized less than 1800 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is indicated when a system is displayed in a muted (dim) magenta?

A

The sensing system is receiving invalid data

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which pumps are not controlled by the hydraulic control panel?

A

1A 2A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What powers hydraulic pump 3B?

A

AC Bus 1, ADG when deployed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If the ADG is providing power to 3B, can it be manually turned off?

A

No switch will not work

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What will affect will the loss of hydraulic systems 2 and 3 have on the landing gear?

A

Manual gear extension is required, and the nose gear will not extend.

17
Q

What purpose does the accumulator serve?

A

It dampens oscillations in pressure

18
Q

What is a normal accumulator charge?

A

1500 psi

19
Q

Which system provides power to the brakes?

A

System 2 and 3. 3 inboard, 2 outboard

20
Q

Which system provides power to the nosewheel steering?

A

3A/3B