Honeywell Titan Flashcards
The Honeywell TITAN SCBA is equipped with a new electronic component within the PASS device that can sense what?
external temperature
The ThermAlert provides an alarm based on what?
heat and time an individual has spent in a fire environment
ThermAlert is a sliding curve of what?
heat and time
Is the sound of the ThermAlert different from the sound of a standard PASS alarm?
Yes
Is ThermAlert a locking alarm?
no, it will automatically stop once the user leaves the range of the curve
ThermAlert temperature chart based on Front PASS external temp to time to activate heat alarm (+/- 0.5min)
200F - 11.0 min
250F - 8.0 min
300F - 6.75 min
350F - 5.25 min
Standard for Open-Circuit Self-Contained Breathing Apparatus (SCBA) for Emergency Services
NFPA 1981
“Standard for Fire Service Respiratory Protection Training”
NFPA 1404
How many carabiner attachments are on backplate and what are they rated to?
4, 1000 lbs
How many motion sensors does the titan have?
two, front PASS and back PASS
How many and what batteries power Titan SCBA?
4 C Alkaline batteries
How many gear straps are on shoulder straps for hanging light gear?
4
How many cubic feet at 4500psi are in a 45 min cylinder?
65.6
How many cubic feet at 4500psi are in a 60 min cylinder?
87
SCBA Valve is CGA handwheel, what is CGA?
compressed gas association
Cylinder burst disc consist of how many parts?
3
-plug
-washer
-burst disc (6750-7500psi)
Cylinders are hydrostatic tested when?
When new and re tested every 5 years
(tested at 7500psi)
SCBA Cylinder has estimated life span of what?
15-30 years
When cleaning facepiece, use a cleaning solution of “warm water” and mild detergent, not to exceed what temp?
120F max
Four LEDs on HUD provide visual alert when air supply is at what per NFPA 2013 systems?
50%, 33% and 10%
At 52% cylinder pressure, LED in 1/2 tank position will flash at 1 second for how long?
22.5 seconds (+/- 2 seconds)
At 10%-33% cylinder pressure, LED in 1/3 tank position will flash _____ at 500 millisecond period
Red
Less than 10% cylinder pressure, LED in 1/3 tank position will flash Red at _____ millisecond period
100
What is the pressure range for the SCBA buddy breathing hose?
70-155psi