HLC 25 Flashcards

1
Q

Given the following conditions:
*Unit 2 is at 45% power
*Pressurizer (PZR) Level Control is selected to the ‘X’ position
*Reactor Regulating System (RRS) Selector is in the RRS 1 position
Subsequently:
*LT-1110X develops a leak on the high pressure connection of the D/P cell (reference leg)
*PZR Pressure is 2235 psia and slowly LOWERING
Which ONE of the following completes the statements below?
Based on the given conditions, the automatic response of the Pressurizer Level Control system is that letdown flow will ____(1)____.
In accordance with 2-AOP-01.10, Pressurizer Pressure And Level, operators are required to place the ____(2)____ to mitigate the event.
A.
(1) RISE
(2) RRS selector switch to the RRS-2 position
B.
(1) RISE
(2) PZR level control selector switch to the ‘Y’ position
C.
(1) LOWER
(2) RRS selector switch to the RRS-2 position
D.
(1) LOWER
(2) PZR level control selector switch to the ‘Y’ position

A

B.
(1) RISE
(2) PZR level control selector switch to the ‘Y’ position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Given the following conditions:
* Unit 2 was tripped from 100% power due to rapidly lowering Pressurizer Level
* Following the Reactor trip, a LOOP occurred
* Pressurizer Pressure is 1350 psia and slowly lowering
* Core Exit Thermocouples indicate 530°F
* 2-EOP-03, LOCA is in progress
Which ONE of the following completes the statements below?
Based on the conditions above, the primary mechanism of RCS heat removal is being provided by ____(1)____.
In accordance with 2-EOP-03, LOCA the STABLE MINIMUM required NR S/G level is ____(2)____.
A.
(1) S/Gs
(2) 35%
B.
(1) S/Gs
(2) 60%
C.
(1) RCS Break Flow
(2) 35%
D.
(1) RCS Break Flow
(2) 60%

A

B.
(1) S/Gs
(2) 60%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Given the following conditions:
* Unit 1 has experienced a Large Break LOCA
* RWT Level is 8 ft and lowering
* 1-EOP-03, LOCA is in progress at Step 37, In preparation for RAS
Which ONE of the following completes the statements below?
IAW 1-EOP-03, the crew is required to REMOVE the power inhibit from SI Recirc valves V3659, SI PUMP MINIFLOW ISOL and V3660, SI PUMP MINIFLOW ISOL by operating the SI Recirc Valves ____(1)____.
An inadvertent closure of a single valve will isolate recirc flow for ____(2)____ ECCS train(s).
A.
(1) supply breakers
(2) BOTH
B.
(1) supply breakers
(2) a SINGLE
C.
(1) RTGB key switches
(2) BOTH
D.
(1) RTGB key switches
(2) a SINGLE

A

C.
(1) RTGB key switches
(2) BOTH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Given the following conditions:
12:00:00
Unit 1 is at 100% power
12:07:00
TE-1151, 1A1 RCP Lower Seal temperature is 180 °F and RISING
12:07:30
1-AOP-01.09A1, 1A1 Reactor Coolant Pump was entered
Which ONE of the following completes the statements below?
As TE-1151 continues to RISE, HCV-14-11A1, Seal Cooler HX Isolation Valve ____(1)____ AUTOMATICALLY CLOSE.
In accordance with 1-AOP-01.09A1, the crew will be required to trip the Reactor and secure the RCP, if the Lower Seal Cavity Temperature exceeds the setpoint of ____(2)____.
A.
(1) will
(2) 200 °F
B.
(1) will
(2) 250 °F
C.
(1) will NOT
(2) 200 °F
D.
(1) will NOT
(2) 250 °F

A

B.
(1) will
(2) 250 °F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Given the following conditions:
* Unit 2 is in Mode 3
* Pressurizer level control system malfunction occurs
* 2-AOP-01.10, Pressurizer Pressure and Level has been entered
* At time 1415 charging and letdown were secured
* RCS temperature is 532°F
* RCS pressure is 2250 psia
* RCP Controlled Bleedoff (CBO) is 1.1 gpm per RCP
* Pressurizer level is 33%
* Last Unidentified RCS leak rate was 0.05 gpm
* No operator actions were taken, and all RCS leakage parameters remained constant for the next two hours
Which ONE of the following describes the EARLIEST time that the Pressurizer will be at the MINIMUM Tech. Spec. 3.4.3, Pressurizer limit?
A. 1501
B. 1531
C. 1537
D. 1546

A

D. 1546

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Given the following conditions:
* Unit 1 is currently shutdown for a refueling outage
* The Reactor Head studs have been detensioned
* The RCS level 35 feet
* Time since reactor shutdown is 250 hours
* Reactor Coolant System (RCS) temperature is 95º F
Subsequently:
* All Shutdown Cooling (SDC) flow was lost due to a piping rupture just downstream of the SDC Heat Exchanger
* 1-AOP-03.02, Shutdown Cooling Abnormal Operations was entered
Which ONE of the following describes the calculated Time to Boil in accordance with 1-AOP-03.02, Attachment 1, Estimated Time to Core Boiling?
The Time to Boil is approximately ________ minutes.
REFERENCE PROVIDED
A. 23
B. 30
C. 33
D. 42

A

B. 30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Given the following conditions:
* Unit 1 is at 100% power
Subsequently:
* Annunciator S-6, CCW Surge Tank Compartment “A” Level Low ALARMS
* Annunciator S-16, CCW Surge Tank Compartment “B” Level Low ALARMS
* 1-AOP-14.01, Component Cooling Water Abnormal Operations is entered
* LG-14-2A, CCW Surge Tank Level indicates 29 inches and SLOWLY LOWERING
* LG-14-2B, CCW Surge Tank Level indicates 29 inches and SLOWLY LOWERING
* LCV-14-1, Demin Water to CCW Surge Tank, is CLOSED
Which ONE of the following completes the statements below?
In accordance with 1-AOP-14.01, if V14103, LCV-14-1 Bypass Valve is mechanically bound closed and will not operate; the crew is required to FIRST attempt to locally align the _____(1)_____ Header to restore CCW Surge Tank Level.
The CCW “N” Header Isolation Valves _____(2)_____ AUTOMATICALLY CLOSE.
A.
(1) Fire Water
(2) will
B.
(1) Fire Water
(2) will NOT
C.
(1) Service Water
(2) will
D.
(1) Service Water
(2) will NOT

A

B.
(1) Fire Water
(2) will NOT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Given the following conditions:
* Unit 2 has experienced a LOCA
* PORV 1474 is stuck OPEN
* 2-EOP-01, SPTA is in progress
* Containment Pressure is 7.2 psig and RISING
* Containment Temperature is 203 °F and RISING
Which ONE of the following completes the statements below?
If the US asks the RO to report current RCS pressure, the RO is required to answer ____(1)____.
In accordance with 2-EOP-01, the Crew is required to CLOSE ____(2)____
REFERENCE PICTURES PROVIDED
A.
(1) 1504 psia
(2) BOTH the Block Valve AND OVERRIDE the PORV
B.
(1) 1504 psia
(2) EITHER the Block Valve OR OVERRIDE the PORV
C.
(1) 1506 psia
(2) BOTH the Block Valve AND OVERRIDE the PORV
D.
(1) 1506 psia
(2) EITHER the Block Valve OR OVERRIDE the PORV

A

A.
(1) 1504 psia
(2) BOTH the Block Valve AND OVERRIDE the PORV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Given the following conditions:
* Unit 1 is at 100% power
* A total loss of feedwater event occurred
* The Reactor Protection System FAILED TO AUTOMATICALLY TRIP the reactor when trip conditions were present
Which ONE of the following completes the statements below?
With NO operator actions, Reactor Power 5 minutes after the ATWS will be ____(1)____ Reactor Power just before the ATWS occurred.
The FSAR credits the ____(2)____ to mitigate a complete loss of feedwater with ATWS accident.
A.
(1) lower than
(2) Diverse Scram System
B.
(1) lower than
(2) Pressurizer Safety Valves
C.
(1) approximately the same as
(2) Diverse Scram System
D.
(1) approximately the same as
(2) Pressurizer Safety Valves

A

A.
(1) lower than
(2) Diverse Scram System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Given the following conditions:
* Unit 1 has experienced a SGTR
* 1-EOP-04, SGTR is in progress at step 10 INITIATE lowering RCS Temperature
Which ONE of following completes the statement below?
Isolate the ruptured S/G when the RCS is cooled down to a procedurally directed ____(1)____ less than ____(2)____, in accordance with 1-EOP-04.
A.
(1) Thot
(2) 510 °F
B.
(1) Thot
(2) 500 °F
C.
(1) REP CET
(2) 510 °F
D.
(1) REP CET
(2) 500 °F

A

A.
(1) Thot
(2) 510 °F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which ONE of the following completes the statement below?
A CAUTION in 2-EOP-10, Station Blackout (SBO), states the following:
Do NOT Restart ____(1)____; if power is from ___(2)___, to prevent exceeding component amperage limits
A.
(1) ICW Pumps (ONLY)
(2) the Station Blackout Crosstie
B.
(1) ICW Pumps (ONLY)
(2) the ONLY operating EDG on Unit 1
C.
(1) ICW or CCW Pumps
(2) the Station Blackout Crosstie
D.
(1) ICW or CCW Pumps
(2) the ONLY operating EDG on Unit 1

A

D.
(1) ICW or CCW Pumps
(2) the ONLY operating EDG on Unit 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Given the following timeline:
HH:MM:SS
00:00:00 Unit 1 tripped from 100% due to a LOCA
1A, 1B and 1C Charging Pumps are running post trip
00:03:00 SIAS Actuates
00:05:00 A Loss of Offsite Power (LOOP) occurs
00:05:10 Both the 1A and 1B EDGs have started and output breakers are CLOSED
Which ONE of the following completes the statements below?
At time 00:05:10, 1A/1B HPSI pumps ____(1)____ running and 1C Charging Pump is
NOT running due to ____(2)___ .
A.
(1) are
(2) load sequencing timer
B.
(1) are
(2) RTGB Control Switch Position
C.
(1) are NOT
(2) load sequencing timer
D.
(1) are NOT
(2) RTGB Control Switch Position

A

C.
(1) are NOT
(2) load sequencing timer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Given the following conditions:
* Unit 2 is at 100% power
* LIC-9023A, B S/G Level Safety Channel is bypassed
* Pressurizer Level Control is in the “X” position
Subsequently:
* Containment Evacuation alarm sounds
* BRCO reports “Multiple alarms”
* Trip Circuit Breakers (TCB) Indications as follows:
o TCBs 1, 2, 5 and 6 OPEN
o TCBs 3, 4, 7, and 8 CLOSED
Which ONE of the following describes (1) the event that occurred and (2) what component will require manual control?
A.
(1) Loss of the 2A 125V Vital DC Bus
(2) Pressurizer Level Control System
B.
(1) Loss of the 2A 125V Vital DC Bus
(2) Steam Generator Water Level Control System
C.
(1) Loss of the 2MA 120VAC Instrument Bus
(2) Pressurizer Level Control System
D.
(1) Loss of the 2MA 120VAC Instrument Bus
(2) Steam Generator Water Level Control System

A

C.
(1) Loss of the 2MA 120VAC Instrument Bus
(2) Pressurizer Level Control System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Given the following conditions:
* Unit 1 is at 100% power
* The 1AB busses are aligned to the “A” train
Subsequently:
* The Unit tripped
* A loss of the 1A DC bus occurs
* 1-EOP-01, Standard Post Trip Actions is in progress
Which ONE of the completes the statements below?
IAW 1-EOP-01, the 1AB DC bus will be re-energized from the ____(1)____.
Feedwater flow to the 1A S/G will be restored using the ____(2)____.
A.
(1) 1B DC bus
(2) 1B AFW Pump via the AFW cross-tie valves
B.
(1) 1B DC bus
(2) 1C AFW Pump
C.
(1) 1AB Battery Charger
(2) 1B AFW Pump via the AFW cross-tie valves
D.
(1) 1AB Battery Charger
(2) 1C AFW Pump

A

B.
(1) 1B DC bus
(2) 1C AFW Pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Given the following conditions:
* Unit 2 tripped due to a SGTR
* 2-EOP-04, SGTR is in progress
* SIAS has actuated
* NPO reports the following Intake Cooling Water (ICW) parameters:
o “A” Turbine Cooling Water (TCW) Hx flowrate is 6000 gpm
o “B” Turbine Cooling Water (TCW) Hx flowrate is 0 gpm
IAW 2-EOP-99, Table 1, SIAS SIGNAL, the crew is required to ____(1)____ ISOLATION VALVE.
____(2)____ will experience a temperature change due to the ICW alignment.
A.
(1) OPEN MV-21-2, HEADER B
(2) Instrument Air Compressors
B.
(1) OPEN MV-21-2, HEADER B
(2) Circulating Water Pump seal coolers
C.
(1) CLOSE MV-21-3, HEADER A
(2) Instrument Air Compressors
D.
(1) CLOSE MV-21-3, HEADER A
(2) Circulating Water Pump seal coolers

A

C.
(1) CLOSE MV-21-3, HEADER A
(2) Instrument Air Compressors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Given the following conditions:
* Unit 1 is at 100% power
* Instrument Air Pressure, Pl-18-9, is 97 psig, slowly LOWERING
Which ONE of the following completes the statements below, in accordance with 1-AOP-18.01, Instrument Air Malfunction, if Instrument Air header pressure continues to LOWER?
The Unit to Unit cross-tie from Unit 2 will OPEN at a setpoint of ____(1)____.
1-AOP-18.01 states the following: “IF Instrument Air header pressure indicates less than ____(2)____ and lowering, THEN PERFORM the following: A. TRIP reactor. B. GO TO 1-EOP-01, Standard Post Trip Actions.
A.
(1) 95 psig
(2) 75 psig
B.
(1) 95 psig
(2) 60 psig
C.
(1) 85 psig
(2) 75 psig
D.
(1) 85 psig
(2) 60 psig

A

D.
(1) 85 psig
(2) 60 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Given the following conditions:
* Unit 2 has tripped from 100% power
* 2-EOP-01, SPTAs are complete
* 2-EOP-02, Reactor Trip Recovery has been entered
Which ONE of the following completes the statement below?
IAW 2-EOP-02, the crew is required to maintain RCS Tavg between ________.
A. 505 and 515 °F
B. 515 and 525 °F
C. 525 and 535 °F
D. 535 and 545 °F

A

C. 525 and 535 °F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Given the following conditions:
10:00
Unit 2 was tripped due to an Excess Steam Demand Event (ESDE) inside Containment
10:01
the crew recognized that the ESDE in progress was from the 2A S/G
10:09
the crew FIRST noticed 2A S/G had reached dryout by observing the Tcold trend below:
Which ONE of the following completes the statements below in accordance with the requirements of ADM-11.16, Transient Procedure Use and Adherence, Section 4.3.1.N, RCS Temperature Stabilization Guidance following an ESDE?
The crew is required to establish a pressure band on the 2B S/G of ____(1)____.
Stabilization of the 2B S/G was required to be commenced____(2)____.
REFERENCE PROVIDED (GRAPH ABOVE)
A.
(1) 300-350 psia
(2) as soon as the crew verified that ONLY the 2A S/G is faulted
B.
(1) 300-350 psia
(2) when the ESDE was terminated, or the 2A S/G was blown dry
C.
(1) 525-575 psia
(2) as soon as the crew verified that ONLY the 2A S/G is faulted
D.
(1) 525-575 psia
(2) when the ESDE was terminated, or the 2A S/G was blown dry

A

B.
(1) 300-350 psia
(2) when the ESDE was terminated, or the 2A S/G was blown dry

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Given the following conditions:
* Unit 1 is at 100% power
* AB Busses are aligned to the “B” train
* 1AA Battery Charger is OOS
Subsequently:
* 1A Battery Charger trips
* 1-AOP-50.08, Loss of 125 VDC Station Battery Charger has been entered
* The crew completes the following actions:
* 1AB Charger is aligned to the 1AB DC Bus
* Divorced the 1AB DC Bus from the 1B DC bus by opening 60135, TIE 1AB-1A (“inside”) and 60130, TIE 1A-1AB (“outside”)
Which ONE of the following completes the statements below?
TS 3.8.2.3 – DC Distribution – Operating, Surveillance Requirement 4.8.2.3.1, D.C. bus train shall be determined OPERABLE and energized, is required to be performed within a MAXIMUM of ____(1)____.
In accordance with 1-AOP-50.08, the operator is required to FIRST CLOSE
____(2)____ breakers to now align the 1AB DC Bus to 1A DC bus.
A.
(1) 30 minutes
(2) 60135, TIE 1AB-1A (“inside”) THEN 60130, TIE 1A-1AB (“outside”)
B.
(1) 30 minutes
(2) 60130, TIE 1A-1AB (“outside”) THEN 60135, TIE 1AB-1A (“inside”)
C.
(1) 1 hour
(2) 60135, TIE 1AB-1A (“inside”) THEN 60130, TIE 1A-1AB (“outside”)
D.
(1) 1 hour
(2) 60130, TIE 1A-1AB (“outside”) THEN 60135, TIE 1AB-1A (“inside”)

A

D.
(1) 1 hour
(2) 60130, TIE 1A-1AB (“outside”) THEN 60135, TIE 1AB-1A (“inside”)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Given the following conditions:
* Unit 2 is at 100% power
Subsequently:
* CEA #1, Reg Group 5 dropped to the bottom of the core
* 2-AOP-66.01, Dropped or Misaligned CEA Abnormal Operations is in progress
Which ONE of the following completes the statements below?
The Core Mimic (Display 6801) for CEA #1 would indicate ____(1)____.
During the recovery of CEA #1, CEA Motion Inhibit (CMI) ____(2)____ be required to be bypassed.
A.
(1) GREEN
(2) will
B.
(1) GREEN
(2) will NOT
C.
(1) ORANGE
(2) will
D.
(1) ORANGE
(2) will NOT

A

C.
(1) ORANGE
(2) will

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Given the following conditions:
* Unit 2 is performing a Reactor Startup in accordance with 2-GOP-302, Reactor
Plant Startup – Mode 3 to Mode 2 at Step 4.5.2, Critical Approach
* Below is the listed initial power levels power to commence approach to criticality
and the power when the reactor was announced critical
SU Channel BF3 (CPS)
WRNI (% Power)

INITIAL
A 50 B 50
A 3 x 10-8 B 3 x 10-8
CRITICAL
A 3200 B 400
A 4 x 10-7 B 3 x 10-7

Which ONE of the following describes the status of the BF3 detectors and can the
startup continue?
SU Channel ____(1)____ is indicating AS EXPECTED.
In accordance with 2-GOP-302, the Reactor Startup ____(2)____ continue?
A.
(1) A ONLY
(2) can
B.
(1) A ONLY
(2) can NOT
C.
(1) B ONLY
(2) can
D.
(1) B ONLY
(2) can NOT

A

A.
(1) A ONLY
(2) can

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Given the following conditions:
* Unit 1 is at 11% power
* The condenser has developed a small air leak
* The crew has entered 1-AOP-12.01, Loss of Condenser Vacuum
* Condenser vacuum indicates 3.5 inHgA and DEGRADING
Which ONE of the following completes the statements below?
In accordance with 1-AOP-12.01, the crew is required to trip the turbine at a setpoint of ____(1)____ inHgA. If the vacuum continues to degrade, the Steam Bypass Control System will become unavailable at a setpoint of ____(2)____ inHgA.
A.
(1) 5.9
(2) 8.859
B.
(1) 5.9
(2) 12
C.
(1) 8.5
(2) 8.859
D.
(1) 8.5
(2) 12

A

D.
(1) 8.5
(2) 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Given the following conditions:
* Unit 1 automatically tripped due to a Small Break LOCA
* The crew is performing the actions of 1-EOP-01, SPTAs
Subsequently:
* RIS-26-3-1, Channel #3 Containment Isolation Radiation Monitor Hi Hi alarm
condition occurs
* The extra RCO is performing the actions of 1-AOP-26.02, Area Radiation
Monitors
Which ONE of the following completes the statement below?
In accordance with 1-AOP-26.02 step 4.2.2.4.A, verifying alarm validity, the BLUE fail
safe light ____(1)____ LIT for a VALID alarm.
RIS-26-3-1 utilizes a ____(2)____ detector.
A.
(1) is
(2) Scintillation
B.
(1) is
(2) Geiger-Mueller
C.
(1) is NOT
(2) Scintillation
D.
(1) is NOT
(2) Geiger-Mueller

A

B.
(1) is
(2) Geiger-Mueller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Given the following conditions:
* Unit 1 tripped due to a LOOP
* ALL AFW has been LOST
* 1-EOP-06, Total Loss of Feed has been entered
Subsequently:
* Offsite power has been restored to the “B” train
* Annunciator A-3, 6.9 kV Swgr 1B1 Δ Current Trip is LIT
Which ONE of the following completes the statements below?
In accordance with 1-EOP-06, the ____(1)____ pump will be FIRST used to restore Feedwater flow.
In order to successfully establish Once Through Cooling ____(2)____ Pump(s) is/are required to be running.
A.
(1) 1B Condensate
(2) ALL available Charging (NO HPSI)
B.
(1) 1B Condensate
(2) at Least 1 High Pressure Safety Injection (HPSI)
C.
(1) 1B Main Feed Water
(2) ALL available Charging (NO HPSI)
D.
(1) 1B Main Feed Water
(2) at Least 1 High Pressure Safety Injection (HPSI)

A

B.
(1) 1B Condensate
(2) at Least 1 High Pressure Safety Injection (HPSI)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Given the following conditions:
* Unit 2 has tripped
* 2-EOP-01, SPTAs are in progress
* Pressurizer pressure is 1800 psia and LOWERING
* Pressurizer level is 15% and LOWERING
* RCS 495 °F and LOWERING
* 2A SG is 800 psia and LOWERING
* 2B SG is 800 psia and LOWERING
* Containment pressure is 1.5 psig and RISING
Which ONE of the following describes the required actions and procedure selection?
Emergency Boration ____(1)____ required and the crew will transition to ____(2)____.
A.
(1) is
(2) 2-EOP-03, LOCA
B.
(1) is
(2) 2-EOP-05, ESDE
C.
(1) is NOT
(2) 2-EOP-03, LOCA
D.
(1) is NOT
(2) 2-EOP-05, ESDE

A

B.
(1) is
(2) 2-EOP-05, ESDE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Given the following conditions:
* Unit 2 tripped from 100% power due to a Loss of Offsite Power (LOOP)
* 2-EOP-09, LOOP/LOFC is in progress
* 30 minutes post trip, the crew commenced a Natural Circulation Cooldown per 2-AOP-01.13, Natural Circulation Cooldown
* The crew cooled down the RCS to 325 °F in 7 hours
Which ONE of the following completes the statements below?
During the RCS cooldown, the S/G ADVs were operated in ____(1)____.
An RCS soak ____(2)____ required to performed IAW 2-AOP-01.13.
A.
(1) manual/manual ONLY
(2) is
B.
(1) manual/manual ONLY
(2) is NOT
C.
(1) auto/manual OR manual/manual
(2) is
D.
(1) auto/manual OR manual/manual
(2) is NOT

A

C.
(1) auto/manual OR manual/manual
(2) is

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Given the following conditions:
* Unit 1 has a SGTR in the 1A S/G
* 1-EOP-04, SGTR is in progress
* LOOP has occurred
* EDGs are supplying power
* MINIMUM Subcooling is MET
* 1-EOP-99, Appendix R, Steam Generator Isolation is in progress
* HCV-08-2A, S/G 1A Atmospheric Dump Valve, will NOT CLOSE
Which ONE of the following completes the statements below?
Appendix R, Steam Generator Isolation directs the Crew to isolate HCV-08-2A ADV by closing the isolation valve ____(1)____.
Based on the given conditions, 1-EOP-04 directs the Crew to COOLDOWN at a rate NOT to exceed ___(2)___ in any 1 hour period.
A.
(1) LOCALLY ONLY
(2) 30 °F
B.
(1) LOCALLY ONLY
(2) 100 °F
C.
(1) at RTGB-102 or LOCALLY
(2) 30 °F
D.
(1) at RTGB-102 or LOCALLY
(2) 100 °F

A

A.
(1) LOCALLY ONLY
(2) 30 °F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Given the following conditions:
* Unit 1 is in Mode 2 performing a Reactor Startup
* Critical Rod Height Data is being taken
* Reactor Power is 5 X 10-4%
* The Board RCO notes:
* RCP 1A1 amps are 500 amps slowly RISING
* RCP 1A2 amps are 425
* RCP 1B1 amps are 415
* RCP 1B2 amps are 420
Which ONE of the following completes the statements below?
Based on these continuing degrading conditions, and no operator action, the Reactor
____(1)____ AUTOMATICALLY TRIP.
In accordance with ADM-11.16, Transient Procedure Use and Adherence, following the
Reactor trip, the BRCO ____(2)____ required to perform 1-EOP-01, SPTAs step 1 from
memory, PRIOR to tripping the 1A1 RCP.
A.
(1) will
(2) is
B.
(1) will NOT
(2) is NOT
C.
(1) will
(2) is
D.
(1) will NOT
(2) is NOT

A

C.
(1) will
(2) is

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

Which ONE of the following describes the operation of the Reactor Coolant Pump (RCP) Oil Lift Pumps after a RCP has tripped?
____(1)____ RCP Oil Lift pump(s) will start on RCP ____(2)____.
A.
(1) BOTH
(2) breaker opening
B.
(1) BOTH
(2) Low Lube Oil Pressure
C.
(1) ONLY the Lead
(2) breaker opening
D.
(1) ONLY the Lead
(2) Low Lube Oil Pressure

A

A.
(1) BOTH
(2) breaker opening

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

Which ONE of the following completes the statements below?
As VCT level changes,
V2504, RWT Suction to Charging Valve OPENS at a setpoint of ____(1)____ and LOWERING.
V2501, VCT Outlet Valve OPENS at a setpoint of ____(2)____ and RISING.
A.
(1) 5%
(2) 15%
B.
(1) 5%
(2) 35%
C.
(1) 15%
(2) 15%
D.
(1) 15%
(2) 35%

A

A.
(1) 5%
(2) 15%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

Given the following conditions:
* Unit 1 is at 300°F and cooling down on Shutdown Cooling (SDC)
* RCS cooldown rate is 75°F/Hr
* HCV-3657, SDC Temp Control is 50% OPEN
* FCV-3306, SDC Return Flow is 100% OPEN
* The crew enters 1-AOP-03.02, Shutdown Cooling
Subsequently:
* A loss of Instrument Air occurs
Which ONE of the following completes the statements below?
FCV-3306, SDC Return Flow, will ____(1)____.
IAW 1-AOP-03.02, Shutdown Cooling Abnormal Operations, the crew will reestablish
the cooldown rate by locally control SDC temperature by THROTTLING HCV-3657,
SDC Temp Control in the ____(2)____ direction.
A.
(1) be failed OPEN
(2) OPEN
B.
(1) be failed OPEN
(2) CLOSED
C.
(1) fail CLOSED
(2) OPEN
D.
(1) fail CLOSED
(2) CLOSED

A

A.
(1) be failed OPEN
(2) OPEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

Given the following conditions:
HH:MM
00:00
Unit 2 has experienced a LOCA
00:15
2-EOP-03, LOCA is entered
00:50
HPSI has been throttled IAW, 2-EOP-99, App S, Safety Injection Throttling and Restoration with the following flows:
Pressurizer level is 32% and slowly RISING
2A Flow is 200 gpm 2B Flow is 400 gpm
01:20
2A HPSI pump trips
01:25
Pressurizer level is 50% and slowly LOWERING
Pressurizer Pressure is 700 psia
SI Flow is 400 gpm
ALL Available Charging Pumps are running
Which ONE of the following completes the statements below?
At time 01:25:00, 2-EOP-99, Figure 2, Safety Injection Flow vs. RCS Pressure ____(1)____ being met.
The crew is required to ____(2)____.
REFERENCE PROVIDED
A.
(1) is
(2) throttle open HPSI header injection valves ONLY
B.
(1) is
(2) BOTH throttle open HPSI header injection valves AND attempt 1 restart of the 2A HPSI pump
C.
(1) is NOT
(2) throttle open HPSI header injection valves ONLY
D.
(1) is NOT
(2) BOTH throttle open HPSI header injection valves AND attempt 1 restart of the 2A HPSI pump

A

A.
(1) is
(2) throttle open HPSI header injection valves ONLY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Given the following conditions:
* Unit 2 is at 100% power
* Annunciator H-32, Quench Tank Level High/Low is LIT
Which ONE of the following completes the statements below?
The HIGH alarm setpoint is ____(1)____ .
IAW 2-ARP-01-H32, the crew is required to reduce level by draining the Quench Tank to the ____(2)____ per 2-NOP-01.07, Quench Tank Operation.
A.
(1) 60%
(2) Hold Up Tank (HUT)
B.
(1) 60%
(2) Reactor Drain Tank (RDT)
C.
(1) 70%
(2) Hold Up Tank (HUT)
D.
(1) 70%
(2) Reactor Drain Tank (RDT)

A

D.
(1) 70%
(2) Reactor Drain Tank (RDT)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

Given the following conditions:
* Unit 1 has just completed drawing a bubble from a solid plant condition
* Pressurizer pressure is 260 psia
* RCS temperature is 185°F
* A PORV is LEAKING fluid to a downstream pressure of 4.0 psig
Which ONE of the following completes the statements below?
Expected PORV tailpipe temperature is ____(1)____.
Technical Specification 3.4.6.2, RCS Operational Leakage limit for RCS leakage through the PORV into the Quench Tank is ____(2)____.
A.
(1) ~400 ºF
(2) 1 gpm
B.
(1) ~400 ºF
(2) 10 gpm
C.
(1) ~320 ºF
(2) 1 gpm
D.
(1) ~320 ºF
(2) 10 gpm

A

D.
(1) ~320 ºF
(2) 10 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

Given the following conditions:
* Unit 2 is at 100% power
* AB Busses are aligned to the “B” side
* 2A and 2B Component Cooling Water (CCW) pumps are running
Subsequently:
* 2A CCW pump has tripped
* The crew has entered 2-AOP-14.01, Component Cooling Water Abnormal Operations
* The crew completes the following actions:
o Mechanically aligns the 2C CCW pump to the “A” CCW Header
o Annunciator S-26, 2C CCW Pump Hdr Valves/AB Bus Misalignment alarms
o Electrically aligns the 2AB 4.16Kv bus to the “A” side (ONLY electrical swap)
o Starts the 2C CCW pump
Which ONE of the following completes the statements below?
Partial CCW flow ____(1)____ continue to the “A” Essential CCW header if all “N” header isolation valves are OPEN.
Unit 2 Tech Spec 3.7.3, CCW, ____(2)____ allow the Crew 2 hours to restore proper CCW system alignment comply with the Technical Specification.
A.
(1) will
(2) does
B.
(1) will
(2) does NOT
C.
(1) will NOT
(2) does
D.
(1) does NOT
(2) does NOT

A

A.
(1) will
(2) does

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

Given the following conditions:
* Unit 1 is at 100% power
* RCS pressure is slowly RISING due an ongoing event
Which ONE of the following completes the statements below?
As RCS Pressure RISES, HIC-1100, PZR Pressure Controller, OUTPUT will ____(1)____.
IF the RCS Pressure continues to RISE, ____(2)____ PORVs will OPEN.
A.
(1) INCREASE
(2) ONE
B.
(1) INCREASE
(2) TWO
C.
(1) DECREASE
(2) ONE
D.
(1) DECREASE
(2) TWO

A

B.
(1) INCREASE
(2) TWO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

Given the following conditions:
* Unit 1 is performing a plant startup in accordance with 1-GOP-201, Reactor Plant Startup – Mode 2 to Mode 1
* Power ascension is in progress
Which ONE of the following completes the statements below?
The Reactor Protection System (RPS) Hi Startup Rate Trip Bypass setpoint is ____(1)____ power.
The RPS Hi Startup Rate trip is bypassed ____(2)____.
A.
(1) 1 %
(2) automatically
B.
(1) 1 %
(2) via operator action
C.
(1) 15 %
(2) automatically
D.
(1) 15 %
(2) via operator action

A

C.
(1) 15 %
(2) automatically

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

Given the following conditions:
* Unit 2 is at 100% power
* The AB electrics are aligned to the “B” Train
* 2A HPSI Pump is OOS
* 2B Charging Pump is OOS
Subsequently:
* Unit 2 has experienced a LOCA
* 2-EOP-03, LOCA is in progress
* ‘B’ ESFAS Cabinet FAILED to actuate
* 2A and 2C Charging Pumps are operating
* 2A LPSI Pump is operating
* RCS Pressure is 500 psia
* RCS CETs are 492 °F
Which ONE of the following completes the statements below?
Core Heat Removal Safety Function ____(1)____ MET.
Safety Injection Tanks ____(2)____ injecting to the RCS
REFERENCE PROVIDED
A.
(1) is
(2) are
B.
(1) is
(2) are NOT
C.
(1) is NOT
(2) are
D.
(1) is NOT
(2) are NOT

A

C.
(1) is NOT
(2) are

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

Given the following conditions:
* Unit 1 is at 100% power
* The 1C CCW Pump is out of service
Subsequently:
* The 1A CCW Pump trips and cannot be restarted
* 1-AOP-14.01, CCW Abnormal Ops has been entered
Which ONE of the following completes the statements below?
1-AOP-14.01, directs the securing of the “A” train Containment Fan Coolers (CFC). CFC 1A and ____(1)____ are required to be stopped.
If Containment Temperature exceeds 120F, the unit must be removed from service within a MAXIMUM OF ____(2)____ minutes.
A.
(1) 1B
(2) 45
B.
(1) 1B
(2) 60
C.
(1) 1C
(2) 45
D.
(1) 1C
(2) 60

A

A.
(1) 1B
(2) 45

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

of Containment

Given the following timeline:
0000
Unit 2 has tripped from 100% power
0015
Containment temperature is 130°F
Containment Pressure is 3.8 psig
Which ONE of the following describes the status of the Containment Coolers at time 0000 and time 0015?
TIME
Coolers Running
Fan
Speed
A.
(1) 0000, THREE (3), FAST
(2) 0015, THREE (3), FAST
B.
(1) 0000, FOUR (4), FAST
(2) 0015, FOUR (4), SLOW
C.
(1) 0000, THREE (3), FAST
(2) 0015, FOUR (4), SLOW
D.
(1) 0000, FOUR (4), FAST
(2) 0015, FOUR (4), FAST

A

C.
(1) 0000, THREE (3), FAST
(2) 0015, FOUR (4), SLOW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

Which ONE of the following completes the statements below?
Unit 2 Containment Spray Pumps ____(1)____ have CCW seal cooling water supply.
Following actuation of RAS, Unit 2 Containment Spray flow ____(2)____ cooled by the Shutdown Cooling (SDC) Heat Exchangers.
A.
(1) do
(2) is
B.
(1) do
(2) is NOT
C.
(1) do NOT
(2) is
D.
(1) do NOT
(2) is NOT

A

A.
(1) do
(2) is

42
Q

Which ONE of the following completes the statements below?
Unit 1 experienced a Turbine Trip, Moisture Separator Reheater (MSR) Block Valves, MV-08-4, MV-08-6, MV-08-8 and MV-08-10, will be ____(1)____ CLOSED.
Unit 1 MSR Block valves can be MANUALLY operated via ____(2)____.
A.
(1) AUTOMATICALLY
(2) an RTGB Control Switch
B.
(1) AUTOMATICALLY
(2) the OVATION System
C.
(1) MANUALLY
(2) an RTGB Control Switch
D.
(1) MANUALLY
(2) the OVATION System

A

A.
(1) AUTOMATICALLY
(2) an RTGB Control Switch

43
Q

Which ONE of the following completes the statements below?
Unit 1 Main Steam System has ____(1)____ Atmospheric Dump Valves (ADVs).
Unit 1 ADVs can be isolated from the Main Steam System via ____(2)____ operated valve.
A.
(1) 2 (TWO)
(2) motor
B.
(1) 2 (TWO)
(2) manual (ONLY)
C.
(1) 4 (FOUR)
(2) motor
D.
(1) 4 (FOUR)
(2) manual (ONLY)

A

B.
(1) 2 (TWO)
(2) manual (ONLY)

44
Q

Given the following conditions:
* Unit 1 is at 60% power during a plant startup
* 1A and 1B Main Feedwater Pumps (MFWP) are operating
Subsequently:
* 1A Condensate Pump trips
* Lowest observed MFWP Suction pressure was 300 psig
Which ONE of the following completes the statements below?
The ____(1)____ will AUTOMATICALLY trip.
The DIRECT cause of the above AUTOMATIC trip signal is an interlock based on ____(2)____.
A.
(1) 1A MFWP ONLY
(2) LOW MFWP Suction Pressure Logic
B.
(1) 1A MFWP ONLY
(2) 1A Condensate Pump Breaker Trip Logic
C.
(1) 1A and 1B MFWPs
(2) LOW MFWP Suction Pressure Logic
D.
(1) 1A and 1B MFWPs
(2) 1A Condensate Pump Breaker Trip Logic

A

B.
(1) 1A MFWP ONLY
(2) 1A Condensate Pump Breaker Trip Logic

45
Q

Given the following conditions:
* Unit 1 is at 100% power
Subsequently:
* Annunciator G-9, 1B S/G Level High/Low is received
* DCS Flat Panel display for FW Control indicates:
* LT-9006, 1B S/G NR Level is BLUE ON WHITE
* LT-9021, 1B S/G NR Level is GREEN
* 1B S/G FWCS MED OUTPUT IS BLACK ON CYAN
* LT-9023 A-D, 1B S/G NR Water Level is 66% and STABLE
Which ONE of the following completes the statements below?
The FWCS Output for the 1B S/G indicates ____(1)____.
Based on the given conditions, 1-AOP-09.01, Feedwater Control Systems Abnormal Operations, Immediate Operator actions ____(2)____ require MANUAL control of 1B MFRV to be taken.
A.
(1) BAD
(2) do
B.
(1) BAD
(2) do NOT
C.
(1) POOR
(2) do
D.
(1) POOR
(2) do NOT

A

D.
(1) POOR
(2) do NOT

46
Q

Given the following conditions:
* Unit 1 tripped from 100% power
* 1C AFW pump is out of service
* AFAS-1 and AFAS-2 has actuated
* AFW flows have been throttled to 250 gpm
* Steam Generator Levels are 27% NR and slowly RISING
* 1-EOP-01, SPTAs are in progress
Subsequently:
* A Loss of Offsite power occurs
Following the completion of EDG load sequencing:
AFW flow rates to the Steam Generators would be ____(1)_____, AND
In accordance with 1-NOP-99.07 Hard Cards, the Crew ____(2)____ REQUIRED to LOWER AFW flow to 150 gpm for the next 5 (FIVE) minutes.
A.
(1) ~250 gpm
(2) is
B.
(1) ~250 gpm
(2) is NOT
C.
(1) ~320 gpm
(2) is
D.
(1) ~320 gpm
(2) is NOT

A

D.
(1) ~320 gpm
(2) is NOT

47
Q

Given the following conditions:
* Unit 1 is at 2% power
* S/G water level is being maintained with the Motor Driven AFW pumps
Subsequently:
* The 1A Auxiliary Feedwater pump trips
Which ONE of the following describes the expected plant response BEFORE the automatic Reactor Trip on Low Steam Generator (S/G) Level?
Reactor Coolant System (RCS) Pressure will ____________.
A. RISE, because the RCS temperature RISES
B. RISE, because the RCS delta T power RISES
C. LOWER, because the S/G level initially RISES (swell phenomenon)
D. LOWER, because the boiling rate in the S/G tube bundle region RISES

A

A. RISE, because the RCS temperature RISES

48
Q

Given the following conditions:
* Unit 2 has tripped from 100% power
* On the trip, the AUTO transfer of the 2A Aux Transformer FAILED
Which ONE of the following describes the RUNNING Reactor Coolant Pumps?
With NO additional operator actions, the ________ Reactor Coolant Pumps are RUNNING.
A. 2A1 and 2B1
B. 2A1 and 2A2
C. 2A2 and 2B1
D. 2A2 and 2B2

A

C. 2A2 and 2B1

49
Q

Given the following conditions:
* Unit 2 is at 100% power
* The AB busses are aligned to the “A” side
* The crew is realigning the “AB” busses from “A” side to “B” side per 2-NOP-52.02, Alignment of 2AB Buses and Components
* The Fire and Security SUPS and Vital AC SUPS Inverters are being removed from service
Which ONE of the following completes the statements below?
The Fire and Security SUPS DC back up power supply is the ____(1)____ 125VDC Bus.
The Vital AC SUPS DC back up power supply is the ____(2)____.
A.
(1) 2C
(2) 2C
B.
(1) 2C
(2) 2D
C.
(1) 2D
(2) 2C
D.
(1) 2D
(2) 2D

A

D.
(1) 2D
(2) 2D

50
Q

Given the following conditions:
* Unit 2 is at 100% power
* The crew is performing the 2B EDG Monthly surveillance per 2-OSP-59.01B
Which ONE of the following completes the statements below?
The 2B EDG SLOW speed start ____(1)____ be performed from the Control Room.
If an EMERGENCY stop of the 2B EDG is required during the 2-OSP-59.01B monthly surveillance run, this ____(2)____ be performed from the Control Room
A.
(1) can
(2) can
B.
(1) can
(2) can NOT
C.
(1) can NOT
(2) can
D.
(1) can NOT
(2) can NOT

A

C.
(1) can NOT
(2) can

51
Q

Given the following conditions:
* Unit 1 is at 100% power
* The SNPO reports that the 1A Diesel Fuel Oil Transfer pump has tripped
* The Diesel Oil Storage Tanks Level is greater than Technical Specification MINIMUM levels
Which ONE of the following completes the statements below?
Technical Specification Limiting Condition for Operation 3.8.1.1, Electrical Power Systems - AC Sources, is ____(1)____.
If a Loss of Offsite Power were to occur, with NO operator actions, the 1A EDG would run ____(2)____.
A.
(1) MET
(2) for ~47 minutes before running out of fuel
B.
(1) MET
(2) with make-up via gravity feed when Day Tank level drops below the low level set point
C.
(1) NOT MET
(2) for ~47 minutes before running out of fuel
D.
(1) NOT MET
(2) with make-up via gravity feed when Day Tank level drops below the low level set point

A

D.
(1) NOT MET
(2) with make-up via gravity feed when Day Tank level drops below the low level set point

52
Q

Given the following conditions:
* NEW fuel receipt is in progress on Unit 2
* A NEW fuel assembly was dropped resulting in a clad breach
* The crew has entered 2-AOP-67.01, Accidents Involving New or Spent Fuel
Which ONE of the following completes the statement below?
A NOTE in 2-AOP-67.01 states that the ____(1)____ radiation associated with a damaged NEW fuel assembly ____(2)____ .
A.
(1) Alpha
(2) will NOT cause actuation of Area or Process Radiation Monitor high radiation alarms
B.
(1) Alpha
(2) may cause actuation of a high radiation signal in the control room and cause isolation of the Fuel Handling Building Ventilation and activate Shield Building Ventilation
C.
(1) Alpha and Beta
(2) will NOT cause actuation of Area or Process Radiation Monitor high radiation alarms
D.
(1) Alpha and Beta
(2) may cause actuation of a high radiation signal in the control room and cause isolation of the Fuel Handling Building Ventilation and activate Shield Building Ventilation

A

A.
(1) Alpha
(2) will NOT cause actuation of Area or Process Radiation Monitor high radiation alarms

53
Q

Given the following conditions:
* Unit 1 is at 100% power
Subsequently:
* Unit 1 tripped due to a LOCA resulting in a SIAS
* HCV-21-7A, Debris Discharge Isolation indicates:
o Green Light ON Red Light OFF
* HCV-21-7B, Debris Discharge Isolation indicates:
o Green Light OFF Red Light ON
Which ONE of the following completes the statements below?
____(1)____ is in the correct SIAS position.
HCV-21-7A or HCV-21-7B, must be operated ____(2)____ to place them in the required position.
A.
(1) HCV-21-7A
(2) on RTGB 102
B.
(1) HCV-21-7A
(2) LOCALLY
C.
(1) HCV-21-7B
(2) on RTGB 102
D.
(1) HCV-21-7B
(2) LOCALLY

A

B.
(1) HCV-21-7A
(2) LOCALLY

54
Q

Given the following conditions:
* Unit 2 is at 100% power
* Annunciator F-5, INSTR AIR PRESS HI/LO alarms
* Instrument Air Pressure Instrument reads 100 psig and LOWERING
The crew ___(1)___ start the standby Instrument Air Compressors from the Control Room
If Instrument Air Pressure continues to lower, the crew is required to commence a Unit shutdown due to ____(2)____.
A.
(1) can
(2) MSIVs failing CLOSED
B.
(1) can
(2) not being able to maintain S/G water level
C.
(1) can NOT
(2) MSIVs failing CLOSED
D.
(1) can NOT
(2) not being able to maintain S/G water level

A

D.
(1) can NOT
(2) not being able to maintain S/G water level

55
Q

Given the following conditions:
* Unit 2 is in Mode 1
* Health Physics just exited containment after performing surveys via the personnel access hatch and NO additional entries will be made
* 0-NOP-68.00, Containment Entries, Attachment 6, Operations Department Containment Entry Checklist has been completed
Which ONE of the following completes the statements below?
After exiting the containment personnel access hatch door seals ____(1)____ REQUIRED to be tested in accordance with 2-OSP-68.03, Airlock Periodic Leak Testing.
In accordance with TS 3.6.1.3, Containment Air Locks, the LOWEST Mode the personnel hatch is required to be operable is ____(2)____.
A.
(1) is
(2) Mode 4
B.
(1) is
(2) Mode 5
C.
(1) is NOT
(2) Mode 4
D.
(1) is NOT
(2) Mode 5

A

A.
(1) is
(2) Mode 4

56
Q

Which ONE of the following completes the statements below?
When describing the Unit 1 and Unit 2 Reactor Coolant Systems, Unit ____(1)____ has a LARGER volume.
This difference in volume must be accounted for during ____(2)____ calculations.
A.
(1) 1
(2) RCS Leak Rate
B.
(1) 1
(2) Boron Concentration
C.
(1) 2
(2) RCS Leak Rate
D.
(1) 2
(2) Boron Concentration

A

D.
(1) 2
(2) Boron Concentration

57
Q

Given the following conditions:
* Unit 2 is at 100% power
* Pressurizer Level Control is selected to “X” channel
Subsequently:
* LT-1110X fails LOW
* The crew enters 2-AOP-01.10, Pressurizer Pressure and Level
Which ONE of the following completes the statement below?
“A” Train Pressurizer Heaters will be de-energized when the power supply breaker on ____(1)____ opens.
After the Back Interlock Bypass Key Switch is placed in LEVEL, power to the “A” side Pressurizer Heaters ____(2)____ be restored.
A.
(1) 2A3 4.16KV Switchgear
(2) CAN
B.
(1) 2A3 4.16KV Switchgear
(2) CAN NOT
C.
(1) 2A3 Load Center
(2) CAN
D.
(1) 2A3 Load Center
(2) CAN NOT

A

B.
(1) 2A3 4.16KV Switchgear
(2) CAN NOT

58
Q

Given the following conditions:
* Unit 2 was at 100% power
* The crew is performing 2-AOP-22.01, Rapid Downpower to remove a Heater Drain Pump from service
Subsequently:
* Reg Group 5 CEA # 69 became mechanically bound and is misaligned from the Group by 10 inches
Which ONE of the following completes the statement below?
CEA # 69 ____(1)____ indication will be HIGHEST.
The ACTUAL CEA #69 position can be determined by using ____(2)____ .
A.
(1) Pulse Counter
(2) Ovation ONLY
B.
(1) Pulse Counter
(2) Either Distributed Control System or Ovation
C.
(1) Reed Switch Position Transmitter (RSPT)
(2) Ovation ONLY
D.
(1) Reed Switch Position Transmitter (RSPT)
(2) Either Distributed Control System or Ovation

A

C.
(1) Reed Switch Position Transmitter (RSPT)
(2) Ovation ONLY

59
Q

Given the following conditions:
* Unit 1 is at 98% power
* CEA #66 has dropped to the bottom of the core, near Linear Range Nuclear Instrument Channel D
* The crew has entered 1-AOP-66.01, Dropped or Misaligned CEA Abnormal Operations
* Multiple annunciators are LIT including:
* L-20, Reactor Power Range Subchannel Deviation
* BEACON Azimuthal Power Tilt - Tq value is 0.060
Which ONE of the following completes the statements below?
L-20 ____(1)____ an expected alarm for this condition.
IF L-20 is VALID, Tech Spec 3.2.4, Azimuthal Power Tilt – Tq ____(2)____ REQUIRED to be entered.
A.
(1) IS
(2) IS
B.
(1) IS
(2) IS NOT
C.
(1) IS NOT
(2) IS
D.
(1) IS NOT
(2) IS NOT

A

A.
(1) IS
(2) IS

60
Q

Given the following conditions:
* Unit 2 is in Mode 3 at Normal Operating Temperature and Pressure
* P8010, SBCS Main Steam Pressure Transmitter, has failed and is out of service
* P8010 input is bypassed per 2-NOP-102.01, DCS Operations
* Steam Bypass (SBCS) is in service with PCV-8801 controlling RCS temperature
Subsequently:
* P8020, SBCS Main Steam Pressure Transmitter, RAPIDLY fails off-scale HIGH
Which ONE of the following complete the statements below?
PCV-8801 position will ____(1)____. PIC-8010, SBCS Master Controller will ____(2)____,
A.
(1) go FULL CLOSED
(2) swap to MANUAL
B.
(1) go FULL CLOSED
(2) remain in AUTOMATIC control
C.
(1) remain AS IS
(2) swap to MANUAL
D.
(1) remain AS IS
(2) remain in AUTOMATIC control

A

C.
(1) remain AS IS
(2) swap to MANUAL

61
Q

Given the following conditions:
* Unit 2 is at 100% power
* Containment Mini Purge is in progress with HVE-7A, Continuous Cntmt/H2 Purge Fan IAW 2-NOP-25.02, Continuous Containment / Hydrogen Purge System Operation
Subsequently:
* Unit 2 tripped due to a SBLOCA
* Crew has entered 2-EOP-03, LOCA
* SIAS and CIAS has actuated
Which ONE of the following completes the statements below?
Based on the above conditions FCV-25-20 and FCV-25-21, Continuous CNMT Purge ISOL (Mini Purge) Valves will CLOSE and HVE-7A, ____(1)____ AUTOMATICALLY TRIP.
The Crew ____(2)____ override the CIAS signal to OPEN the Continuous CNMT Purge ISOL (Mini Purge) Valves to facilitate hydrogen removal per App N, Hydrogen Purge System Operation.
A.
(1) will
(2) can
B.
(1) will
(2) can NOT
C.
(1) will NOT
(2) can
D.
(1) will NOT
(2) can NOT

A

C.
(1) will NOT
(2) can

62
Q

Which ONE of the following completes the statements below?
In accordance with TS 3.9.11, Spent Fuel Storage Pool, a MINIMUM level of ____(1)____ feet over the top of irradiated fuel assemblies is required.
____(2)____ is(are) used on the SFP cooling return to prevent a passive leak from draining the Spent Fuel Pool.
A.
(1) 23
(2) A check valve
B.
(1) 23
(2) Siphon breaker holes
C.
(1) 29.5
(2) A check valve
D.
(1) 29.5
(2) Siphon breaker holes

A

B.
(1) 23
(2) Siphon breaker holes

63
Q

Given the following conditions:
* Unit 2 is at 12% power
* The Main Generator is synchronized to the grid
* The Main Generator picked up 40 MWe and then tripped after 5 seconds
Which ONE of the following describes the expected plant response with NO operator actions 1 minute later?
A. Reactor power indicates 12% with SBCS opening to control pressure
B. Reactor power indicates 12% with ADVs opening to control temperature
C. The High Power Feed Reg Valves controlling SG levels in automatic
D. Trip Circuit Breaker (TCB) lights indicate ‘GREEN’ with SBCS closing to control pressure

A

A. Reactor power indicates 12% with SBCS opening to control pressure

64
Q

Given the following conditions:
* Unit 1 Liquid Waste Radiation Monitor R-6627 has been declared out of service
* The crew is performing a liquid release IAW 1-NOP-06.01, Controlled Liquid Release to the Circulating Water Discharge
Which of the following LISTED actions describe the MINIMUM required to perform a controlled liquid release to the Circulating Water Discharge, IAW 1-NOP-06.01?
1. An independent verification of the Initial valve alignment
2. Two independent radioactivity analysis of the tank to be released
3. Two independent release rate calculations
1-NOP-06.01
Controlled Liquid Release to the Circulating Water Discharge
ACTIONS REQUIRED, ACTIONS NOT REQUIRED
A. 1 AND 2, 3
B. 1 AND 3, 2
C. 2 AND 3, 1
D. 1, 2 AND 3, NONE

A

D. 1, 2 AND 3, NONE

65
Q

Given the following conditions:
* Unit 2 Component Cooling Water (CCW) system has developed a leak
* LA-10, CCW SURGE TANK COMPARTMENT A LEVEL LOW, is locked in
* LB-10, CCW SURGE TANK LEVEL HIGH/COMPARTMENT B LEVEL LOW, alarmed but subsequently clears
Which ONE of the following describes the CCW system load that is LOST and the actions needed to restore CCW to that load per 2-AOP-14.01, CCW Abnormal Operations?
CCW is LOST to the ____(1)____.
The Crew is required to place the ____(2)____.
A.
(1) Fuel Pool Heat Exchanger
(2) “A” train “N” Header valve control switches to CLOSE then OPEN
B.
(1) Fuel Pool Heat Exchanger
(2) “B” train “N” Header valve control switches to CLOSE then OPEN
C.
(1) Letdown Heat Exchanger
(2) “A” train “N” Header valve control switches to CLOSE then OPEN
D.
(1) Letdown Heat Exchanger
(2) “B” train “N” Header valve control switches to CLOSE then OPEN

A

D.
(1) Letdown Heat Exchanger
(2) “B” train “N” Header valve control switches to CLOSE then OPEN

66
Q

Given the following conditions:
* BOTH Units are at 100% power
* MINIMUM Shift Crew Complement is filling ALL required positions
* At 03:30 the Unit 1 Desk RCO (DRCO) had to leave site due to an emergency
In accordance with OPS Policy 201, Shift Complement, which ONE of the following describes how the position can be filled.
The VACANT DRCO Position ____(1)____ remain vacant until shift turnover occurs at 06:30 and being filled by the oncoming DRCO.
If the Shift Manager fills the STA position in a dual role, the STA (SRO Licensed) ____(2)____ fill the DRCO position.
A.
(1) can
(2) can
B.
(1) can
(2) can NOT
C.
(1) can NOT
(2) can
D.
(1) can NOT
(2) can NOT

A

C.
(1) can NOT
(2) can

67
Q

Which ONE of the following states the MINIMUM Shutdown Cooling flow necessary to reduce RCS boron concentration in accordance with Tech Spec 3.1.1.3, Boron Dilution?
A. 4117 gpm
B. 3570 gpm
C. 3000 gpm
D. 1000 gpm

A

C. 3000 gpm

68
Q

Given the following conditions:
* Unit 2 Core Reload is in progress
* BOTH BF3 Log Startup Channels are in service
* Audible count rate monitoring is selected to “B” Channel
Subsequently:
* The “B” BF3 Log Startup Channel has failed low
IAW 0-NOP-67.05, Refueling Operation, which ONE of following describes the impact on the fuel movement?

A. With the “B” BF3 Log Startup Channel inoperable, the core reload MUST STOP until it is returned to service
B. The core reload can continue by substituting a Wide Range Log Safety Channel and selecting the audible count rate to that WRNI channel
C. The core reload can continue by substituting an Appendix R Wide Range (Excore) and selecting the audible count rate to “A” BF3 Log Startup Channel
D. The core reload can continue with the operable “A” BF3 Log Startup Channel as the ONLY available Source Range indication, as long as audible count rate is selected for that channel.

A

C. The core reload can continue by substituting an Appendix R Wide Range (Excore) and selecting the audible count rate to “A” BF3 Log Startup Channel

69
Q

Which ONE of the following completes the statements below?
IAW Technical Specifications, Table 1.2, Operational Modes, Mode 6 Keff is required to be less than or equal to ____(1)____.
When transitioning from Mode 6 and entering Mode 5, Mode 5 is entered when the ____(2)____ Rx Vessel Head Stud is fully tensioned.
A.
(1) 0.99
(2) FIRST
B.
(1) 0.99
(2) LAST
C.
(1) 0.95
(2) FIRST
D.
(1) 0.95
(2) LAST

A

D.
(1) 0.95
(2) LAST

70
Q

Which ONE of the following completes the statements below?
In accordance with TS 3.1.1.5, Minimum Temperature for Criticality, the Reactor Coolant System lowest operating loop temperature (Tavg) shall be greater than or equal to ____(1)____ in Modes 1 and 2.
With a Reactor Coolant System operating loop temperature (Tavg) less than the value above, the crew is required to restore Tavg to within its limit within a MAXIMUM of ____(2)____.
A.
(1) 515°F
(2) 15 minutes
B.
(1) 515°F
(2) 30 minutes
C.
(1) 525°F
(2) 15 minutes
D.
(1) 525°F
(2) 30 minutes

A

B.
(1) 515°F
(2) 30 minutes

71
Q

Given the following conditions:
* Unit 1 is performing a plant start up IAW 1-GOP-201, Mode 2 to Mode 1
* Reactor Power is 10% on hold for turbine roll
* A very small RCS leak is suspected inside containment
Which ONE of the following completes the statements below IAW 0-NOP-68.00, Containment Entries Modes 1 - 4?
The Containment Evacuation Alarm is tested via ____(1)____.
Personnel ____(2)____ enter the biological shield wall to determine the location of the leak.
A.
(1) Pushbutton at Unit Supervisor Desk
(2) Can
B.
(1) Pushbutton at Unit Supervisor Desk
(2) Can NOT
C.
(1) Key switch on the Rad Monitoring Panel D
(2) Can
D.
(1) Key switch on the Rad Monitoring Panel D
(2) Can NOT

A

B.
(1) Pushbutton at Unit Supervisor Desk
(2) Can NOT

72
Q

Which ONE of the following completes the statement below?
In accordance with RP-AA-101, Personnel Monitoring Program Total Effective Dose Equivalent (TEDE) Administrative limit for Radiation Workers with NO extensions is ____(1)____.
In accordance with HPP-30, Personnel Monitoring, Appendix 6, Authorization to Exceed Administrative Limits, The MAXIMUM TEDE Annual Limit can be authorized for NON-EMERGENCY situations is ____(2)_____.
A.
(1) 2000 mrem / year
(2) 4500 mrem / year
B.
(1) 2000 mrem / year
(2) 5000 mrem / year
C.
(1) 3000 mrem / year
(2) 4500 mrem / year
D.
(1) 3000 mrem / year
(2) 5000 mrem / year

A

A.
(1) 2000 mrem / year
(2) 4500 mrem / year

73
Q

Given the following conditions:
* Unit 1 has just tripped
Prior to procedure in hand implementation of 1-EOP-01, Standard Post Trip Actions, which ONE of the following CAN BE performed by the RO WITHOUT concurrence of the Unit Supervisor IAW ADM-11.16, Transient Procedure Use and Adherence?

A. Closing the MSIVs due to the Turbine not tripping
B. Establishing Auxiliary Feedwater Flow to the Steam Generators
C. Closing the MSR TCVs due to the MSR Block valves not closing
D. Starting an additional Charging Pump with Pressurizer level lowering rapidly

A

A. Closing the MSIVs due to the Turbine not tripping

74
Q

Given the following conditions:
* Unit 2 has tripped from 100% power
* 2-EOP-01, SPTAs is in progress
* Pressurizer Pressure is 1580 psia and lowering
* Pressurizer Level is 38% and rising
* RCS Subcooling is 18 °F and slowly lowering
* The crew is performing step 4, RCS Inventory Control
Which ONE of the following describes the required actions?
The crew is required to ____(1)____ Charging Pump, due to a ____(2)____ piping LOCA.
A.
(1) START the 2C
(2) RCS Cold Leg
B.
(1) START the 2C
(2) Pressurizer Steam Space
C.
(1) SECURE the 2B
(2) RCS Cold Leg
D.
(1) SECURE the 2B
(2) Pressurizer Steam Space

A

B.
(1) START the 2C
(2) Pressurizer Steam Space

75
Q

Given the following conditions:
* Unit 2 is in Mode 5
* RCS Temperature is 110°F
* RCS is at mid-loop conditions
* RCS Time to boil is 22 minutes
* Shutdown Cooling is in operation per 2-NOP-03.05, Shutdown Cooling
Subsequently:
* The running Shutdown Cooling pump trips due to bearing failure
* The crew enters 2-AOP-03.02, Shutdown Cooling Abnormal Operations
In accordance with 2-AOP-03.02, which ONE of the following completes the statements below?
The _____(1)_____ Shutdown Cooling Train will be placed in Operation.
Containment Evacuation ____(2)____ required.
A.
(1) 2A
(2) is
B.
(1) 2A
(2) Is NOT
C.
(1) 2B
(2) is
D.
(1) 2B
(2) Is NOT

A

C.
(1) 2B
(2) is

76
Q

Given the following conditions:
*Unit 1 is experiencing a SBLOCA
*1-EOP-03, LOCA, is in progress
*CEAs 1 and 6 indicate fully withdrawn
*REP CET is 550 °F
*Thot is 548 °F
*Pressurizer Pressure is 1600 psia
*Pressurizer Level is 33% RISING slowly
*BOTH S/Gs are 65% NR Level
Which ONE of the following completes the statements below?
HPSI throttling criteria ____(1)____ MET.
WHEN HPSI throttling criteria is MET, AND pressurizer level remains stable when the required pumps are secured, a MINIMUM of ____(2)____ (if any) Charging / HPSI pump(s) must remain in operation.
REFERENCE PROVIDED
A.
(1) is
(2) ZERO (0)
B.
(1) is
(2) ONE (1)
C.
(1) is NOT
(2) ZERO (0)
D.
(1) is NOT
(2) ONE (1)

A

B.
(1) is
(2) ONE (1)

77
Q

Given the following conditions:
* Unit 1 is at 100% power
* 1-OSP-02.07, Borated Water Sources, was completed with the following results:
* 1A Boric Acid Makeup Tank SAT
* 1B Boric Acid Makeup Tank UNSAT
* 1A/1B Boric Acid Makeup Tanks Combined SAT
* Refueling Water Tank SAT
Subsequently:
* Annunciator M-41, Boric Acid Gravity Feed V2509 Ovrld/SS Isol Alarms
* BRCO reports BOTH Lights for V2509 are NOT LIT
Which ONE of the following completes the statements below?
V2509, 1A BAMT Gravity Feed Valve to Charging Pump status indications are indicative of a ____(1)____.
In accordance with Unit 1 Technical Specifications, TS 3.5.2, ECCS Subsystems – Operating ____(2)____ met.
REFERENCE PROVIDED
A.
(1) Thermal Overload Trip
(2) is
B.
(1) Thermal Overload Trip
(2) is NOT
C.
(1) Blown Control Power Fuse
(2) is
D.
(1) Blown Control Power Fuse
(2) is NOT

A

D.
(1) Blown Control Power Fuse
(2) is NOT

78
Q

Given the following conditions:
* Unit 1 is in Mode 6
* RCS Level is 56 feet
* Rod latching is in progress
* Both trains of Shutdown Cooling (SDC) are in service
* SDC purification is NOT in service
Subsequently:
* A leak occurs at the suction of the 1A LPSI pump
* Annunciator R-4, “A” Safeguards Pump Room Sump Level HI/HI-HI is LIT
* Crew enters 1-AOP-01.08, Excessive RCS Leakage
Which ONE of the following completes the statements below?
To ISOLATE the 1A LPSI Pump suction leak from the RCS, LOCAL valve manipulation ____(1)___ required.
When the leak was isolated per 1-AOP-01.08 with RCS level at 55 feet, compliance with TS 3.9.8.1, Shutdown Cooling and Coolant Circulation High Water Level ____(2)____ maintained.
A.
(1) is
(2) is
B.
(1) is
(2) is NOT
C.
(1) is NOT
(2) is
D.
(1) is NOT
(2) is NOT

A

C.
(1) is NOT
(2) is

79
Q

Given the following conditions:
* Unit 1 is at 100% power
Subsequently:
* A Loss of Power event occurs
Which ONE of the following completes the statements below?
1-EOP-10, Station Blackout is entered if a Loss of all ____(1)____ occurred.
An Extended Loss of AC Power (ELAP) is declared if power is NOT expected to be restored within a MAXIMUM of ____(2)____.
A.
(1) AC power ONLY
(2) 2 hours
B.
(1) AC power ONLY
(2) 4 hours
C.
(1) AC and DC power
(2) 2 hours
D.
(1) AC and DC power
(2) 4 hours

A

B.
(1) AC power ONLY
(2) 4 hours

80
Q

Given the following conditions:
* Unit 1 is in Mode 1
* System Operator reports that grid demand is high
* Main Generator VARS is 0 MVARs
Subsequently:
* A grid disturbance occurs, resulting in grid voltage lowering to 228 kV
* 0-AOP-53.02, Switchyard Voltage is entered
Which ONE of the following completes the statements below?
In accordance with 0-AOP-53.02 and Tech Spec 3.8.1.1, A.C. Sources, Operating, Unit 1 AC offsite sources are ____(1)____.
With NO operator action, Unit 1 Main Generator MVARs will change in the ____(2)____ direction.
A.
(1) OPERABLE
(2) LAG (OUT)
B.
(1) OPERABLE
(2) LEAD (IN)
C.
(1) INOPERABLE
(2) LAG (OUT)
D.
(1) INOPERABLE
(2) LEAD (IN)

A

C.
(1) INOPERABLE
(2) LAG (OUT)

81
Q

Given the following conditions:
* Unit 1 has experienced a Total Loss of Feedwater (TLOF)
* 1-EOP-06, TLOF is in progress at Step 12, Verify RCS Heat Removal
* 1A S/G level is 17% wide range
* 1B S/G level is 4% wide range
* The Atmospheric Dump Valves (ADVs) are FULL OPEN
* Tcold has RISEN steadily from 535° to 541°F over the past 3 minutes
Which ONE of the following completes the statements below?
1-EOP-06, requires the operators to establish OTC based upon the given ____(1)____.
The Unit Supervisor is required to establish OTC by ____(2)____.
A.
(1) S/G Levels
(2) performing 1-EOP-06, Step 12 Contingency Steps
B.
(1) S/G Levels
(2) transitioning to 1-EOP-15, Functional Recovery and performing the RCS and Core Heat Removal; HR-3 Success Path 3 - Once-Through-Cooling success path
C.
(1) Tcold RISE
(2) performing 1-EOP-06, Step 12 Contingency Steps
D.
(1) Tcold RISE
(2) transitioning to 1-EOP-15, Functional Recovery and performing the RCS and Core Heat Removal; HR-3 Success Path 3 - Once-Through-Cooling success path

A

C.
(1) Tcold RISE
(2) performing 1-EOP-06, Step 12 Contingency Steps

82
Q

Given the following conditions:
* Unit 2 is at 50% power
* Group 5 CEAs RSPT and Pulse Counts are at 122 inches
* Group 5 CEA 59 RSPT is at 117 inches and Pulse Count is 122 inches
* Attempts to realign CEA 59 per 2-NOP-99.07, Operations Hard Cards has been unsuccessful
* The crew has entered 2-AOP-66.01, Dropped or Misaligned CEA Abnormal Operations
Subsequently:
* I&C troubleshooting reports CEA 59 is untrippable
Which ONE of the following completes the statements below?
ASI for the LRNI nearest CEA 59 will be more ____(1)____ as compared to the other LRNIs.
In accordance with 2-AOP-66.01, plant shutdown ____(2)____ required.
A.
(1) negative
(2) is
B.
(1) negative
(2) is NOT
C.
(1) positive
(2) is
D.
(1) positive
(2) is NOT

A

C.
(1) positive
(2) is

83
Q

Given the following conditions:
* Unit 2 has evacuated the Control Room due to the presence of toxic fumes
* All Operator actions in the Control Room were performed prior to evacuation
* Critical actions from Appendix A through D of 2-AOP-100.02, Control Room Inaccessibility have been completed
* RCO A is maintaining Hot Standby conditions at the Hot Shutdown Control Panel
Which ONE of the following completes the statements below?
Determine subcooling margin using 2-AOP-100.02, Attachment, 10 Figure 2, using Hot Shutdown Control Panel indication for Reactor Coolant System ____(1)____ and Pressurizer pressure.
In accordance with 2-AOP-100.02, If plant control is NOT established at the Hot Shutdown Control Panel within a MAXIMUM of ____(2)____ minutes following Control Room evacuation, then this event shall be classified as a Site Area Emergency.
A.
(1) Thot
(2) 15
B.
(1) Thot
(2) 30
C.
(1) Tcold + 50 °F
(2) 15
D.
(1) Tcold + 50 °F
(2) 30

A

C.
(1) Tcold + 50 °F
(2) 15

84
Q

Given the following conditions:
* Unit 1 is at 100% power for the past 100 days
* At 0600 on 12/15/2020, Chemistry reports Dose Equivalent Iodine I-131 is 25 μCi/gram
* 1-AOP-01.06, Excessive RCS Activity is entered
* Dose Equivalent Iodine I-131 remains unchanged
Subsequently:
* At 0000 on 12/18/2020, Chemistry reports an increase in Dose Equivalent Iodine I-131 to 70 μCi/gram
In accordance with 1-AOP-01.06, the crew is required to ENSURE V6307, Flash Tank
Diverter Valve is aligned to the ____(1)____.
In accordance with TS 3.4.8, Reactor Coolant System Specific Activity, the latest time Unit 1 is required to be in Mode 3 by ____(2)____.
REFERENCE PROVIDED
A.
(1) Flash Tank
(2) 1200, 12/17/2020
B.
(1) Flash Tank
(2) 0600, 12/18/2020
C.
(1) Hold Up Tank
(2) 1200, 12/17/2020
D.
(1) Hold Up Tank
(2) 0600, 12/18/2020

A

A.
(1) Flash Tank
(2) 1200, 12/17/2020

85
Q

Given the following conditions:
* Unit 1 is experiencing a LOCA
* 1-EOP-03, LOCA is in progress
* The following parameters are observed
Time 0045 0100 0115
CET 430 °F 445 °F 446 °F
RCS Pressure 550 psia 550 psia 550 psia
Pzr Level 0% 0% 0%
ECCS Flow 500 gpm 350 gpm 340 gpm
Containment Temp 174 °F 176 °F 178 °F
Which ONE of the following completes the statement below?
In accordance with ADM-11.16, Transient Procedure Use and Adherence, based on
parameters at time ___(1)____ the crew MUST exit 1-EOP-03 and implement 1-EOP-
15, Functional Recovery, Success Path ____(2)____.
REFERENCE PROVIDED
A.
(1) 0100
(2) IC-2 – Inventory Control
B.
(1) 0100
(2) PC-3 - Saturated Pressure Control
C.
(1) 0115
(2) IC-2 – Inventory Control
D.
(1) 0115
(2) PC-3 - Saturated Pressure Control

A

C.
(1) 0115
(2) IC-2 – Inventory Control

86
Q

Given the following conditions:
* Unit 1 has been shutdown for 150 hours and is in Mode 6
* RCS Temperature is 105 °F
* CCW Temperature is 85 °F
* 1A LPSI pump is operating
* RCS level is 34 feet 10 inches
Subsequently:
* 1A LPSI pump discharge flow is oscillating between 50 and 800 GPM
* 1A LPSI pump motor amps are oscillating and discharge pressure is fluctuating
* RCS temperature is 110 °F and slowly RISING
* The crew enters 1-AOP-03.02, Shutdown Cooling Abnormal Operations
Which ONE of the following completes the statements below?
In accordance with 1-AOP-03.02. the crew is required to FIRST ____(1)____.
In accordance with TS 4.9.8.2. Refueling Operations - Low Water Level Surveillance Requirements, the MINIMUM SDC flow for this condition is ____(2)____ gpm.
A.
(1) STOP the 1A LPSI Pump then START the 1B LPSI Pump
(2) 1850
B.
(1) STOP the 1A LPSI Pump then START the 1B LPSI Pump
(2) 3000
C.
(1) THROTTLE CLOSED HCV-3615/3625, LPSI header injection valves
(2) 1850
D.
(1) THROTTLE CLOSED HCV-3615/3625, LPSI header injection valves
(2) 3000

A

D.
(1) THROTTLE CLOSED HCV-3615/3625, LPSI header injection valves
(2) 3000

87
Q

Given the following conditions:
* Unit 2 is at 100% power
Subsequently:
* Unit 2 SNPO reports a significant Component Cooling Water (CCW) leak from the 2A HPSI Pump Seal Cooler
* The SNPO has isolated the leak by isolating the 2A HPSI Pump Seal Cooler
Which ONE of the following completes the statements below?
In accordance with ADM-11.16, Transient Procedure Use and Adherence, the US is required to declare the ____(1)____ inoperable.
2-EOP-03, LOCA states that during emergency situations, the 2A HPSI Pump ____(2)____ be operated for up to 24 hours with CCW isolated.
A.
(1) 2A HPSI pump ONLY
(2) can
B.
(1) 2A HPSI pump ONLY
(2) can NOT
C.
(1) 2A HPSI pump and 2A CCW Header
(2) can
D.
(1) 2A HPSI pump and 2A CCW Header
(2) can NOT

A

A.
(1) 2A HPSI pump ONLY
(2) can

88
Q

Given the following conditions:
* Unit 2 is at 100% power when the 2B MFW pump trips
* The following annunciators have alarmed:
o L-3, S/G Level Low Channel Trip (Red)
o L-11, S/G Level Low Channel Pre-trip
* Control Room Reactor Trip breaker indications indicate WHITE
Subsequently:
* The BRCO depresses the manual reactor trip pushbuttons
* Control Room Reactor Trip breaker indications indicate WHITE
Which ONE of the following completes the statements below?
In accordance with 2-EOP-01, SPTAs, Step 1, Verify Reactor Trip, the NEXT required action the crew is required to take is ____(1)____.
In accordance with EPIP-01, Classification of Emergencies, this event will be classified as a / an ____(2)____.
REFERENCE PROVIDED
A.
(1) INITIATE Emergency Boration
(2) ALERT
B.
(1) INITIATE Emergency Boration
(2) SITE AREA EMERGENCY
C.
(1) open CEDM MG breakers locally at 2A2 and 2B2 Load Centers
(2) ALERT
D.
(1) open CEDM MG breakers locally at 2A2 and 2B2 Load Centers
(2) SITE AREA EMERGENCY

A

D.
(1) open CEDM MG breakers locally at 2A2 and 2B2 Load Centers
(2) SITE AREA EMERGENCY

89
Q

Given the following conditions:
* Unit 1 tripped from 100% power
* Station Blackout (SBO) conditions exist
* 1-EOP-01, SPTAs is in progress at step 2, MVA
Which ONE of the following completes the statements below?
The FSAR (Section 15.2.13 Station Blackout Analysis) discusses the ability of operators from both units to align the AB 4.16 Buses and supply power through the Station Blackout Crosstie within ____(1)____ hour(s).
The FSAR assumes RCS heat removal will be accomplished using ____(2)____ during the time required to crosstie power.
A.
(1) 1
(2) ADVs
B.
(1) 1
(2) MSSVs
C.
(1) 4
(2) ADVs
D.
(1) 4
(2) MSSVs

A

B.
(1) 1
(2) MSSVs

90
Q

Given the following conditions:
* Unit 2 is at 100% power
* RS-26-11, Steam Jet Air Ejector (SJAE) Monitor is Out of Service
* S/G Dose Equivalent I-131 is 0.0003 μCi/gm
Subsequently:
* RS-26-5, “A” S/G Blowdown Rad Monitor detector output fails HIGH
Which ONE of the following completes the statements below?
S/G Blowdown flow will isolate on ____(1)____ S/G(s).
In accordance with the Off Site Dose Calculation Manual, (C-200), S/G samples are required at a MINIMUM every ____(2)____ hours.
REFERENCE PROVIDED
A.
(1) BOTH
(2) 8
B.
(1) BOTH
(2) 24
C.
(1) ONLY the A
(2) 8
D.
(1) ONLY the A
(2) 24

A

C.
(1) ONLY the A
(2) 8

91
Q

Given the following conditions:
* Unit 2 is stabilizing from a rapid downpower
* ASI is per the graph provided
Which ONE of the following completes the statements below?
To restore ASI to the acceptable band, CEAs must be ____(1)____.
In accordance with TS 3.2.5, ASI, BASES, Operating within ASI limits will result in meeting the ____(2)____ criterion in the event of a limiting transient.
REFERENCE PROVIDED
A.
(1) INSERTED
(2) DNBR
B.
(1) INSERTED
(2) RADIAL POWER DISTRIBUTION
C.
(1) WITHDRAWN
(2) DNBR
D.
(1) WITHDRAWN
(2) RADIAL POWER DISTRIBUTION

A

C.
(1) WITHDRAWN
(2) DNBR

92
Q

Given the following conditions:
* Unit 1 has experienced a SGTR
* 1-EOP-04, SGTR is in progress at Step 10, INITIATE lowering RCS Temperature
* Cooldown with SBCS Valve PCV-8801, is in progress
Subsequently:
* An Instrument Air (IA) rupture occurs, resulting in a Loss of IA
Which ONE of the following completes the statements below?
PCV-8801 will fail ____(1)____.
IAW 1-EOP-04, the crew will continue the cooldown via step 10 Contingency Action, the US will be required to utilize ____(2)____ to continue the cooldown.
A.
(1) as is
(2) Table 12, Alternate S/G Heat Removal Paths
B.
(1) as is
(2) Appendix U, Local Operation of Unit 1 Atmospheric Dump Valves
C.
(1) closed
(2) Table 12, Alternate S/G Heat Removal Paths
D.
(1) closed
(2) Appendix U, Local Operation of Unit 1 Atmospheric Dump Valves

A

D.
(1) closed
(2) Appendix U, Local Operation of Unit 1 Atmospheric Dump Valves

93
Q

Given the following conditions:
* Unit 1 is at 100% power
* Fire Alarm for fire zone 6A is alarming
* SNPO reports NO fire with the following four detectors alarming:
o Detectors 6A-1, 6A-8, 6A-14 and 6A-19
Subsequently:
* Fire Protection determines NO Detectors are ADJACENT detectors
* All four failed detectors have been bypassed per 0-NOP-79.01, Fire Detection System
* Fire Zone 6A alarm has be reset and remains clear
* NO other are detectors are bypassed
Which ONE of the following completes the statements below?
Per ADM-19.00, Fire Protection Plan, ____(1)____ fire watch is required.
This area is protected by a ____(2)____ system.
REFERENCE PROVIDED
A.
(1) NO
(2) Halon
B.
(1) NO
(2) Pre-action
C.
(1) a CONTINUOUS
(2) Halon
D.
(1) a CONTINUOUS
(2) Pre-action

A

A.
(1) NO
(2) Halon

94
Q

Given the following conditions:
* Unit 1 is at 100% power
* The 1A1 Circulating Waterbox has a condenser tube leak
* Annunciator G-20, Secondary Chemistry Alarm is LIT, due to sodium levels
* Chemistry Reports S/G chemistry has entered Action Level 3
* The crew entered 1-AOP-09.03, Secondary Chemistry
* The crew commenced a rapid downpower per 1-AOP-22.01, Rapid Downpower
Which ONE of the following completes the statement below in accordance with 1-AOP-09.03, Secondary Chemistry?
The 1A1 Circulating Water Pump will be secured by placing the control switch to ____(1)____.
Unit 1 is required INITIATE a shutdown to at LEAST ____(2)____.
A.
(1) STOP
(2) Mode 3, Hot Standby
B.
(1) STOP
(2) Mode 5, Cold Shutdown
C.
(1) PULL TO DRAIN
(2) Mode 3, Hot Standby
D.
(1) PULL TO DRAIN
(2) Mode 5, Cold Shutdown

A

C.
(1) PULL TO DRAIN
(2) Mode 3, Hot Standby

95
Q

Given the following conditions:
* Unit 1 is performing a FULL CORE OFFLOAD
Which ONE of the following completes the statements below?
In accordance with 0-NOP-67.05, Refueling Operation, the Refueling Supervisor____(1)____ direct the CORE OFFLOAD activities from the FUEL HANDLING BUILDING.
In accordance with Ops policy 202, Fuel Handling Supervisor Responsibilities, a Non-licensed Fuel Handling Supervisor ____(2)____ directly supervise fuel handling activities associated with movement of irradiated fuel assemblies in the FUEL HANDLING BUILDING.
A.
(1) can
(2) can
B.
(1) can
(2) can NOT
C.
(1) can NOT
(2) can
D.
(1) can NOT
(2) can NOT

A

C.
(1) can NOT
(2) can

96
Q

Given the following conditions:
* Unit 1 is at 100% power
* The Current Time is 0900
* Maintenance is scheduled for the:
* 1A Containment Spray pump
* V1402, PORV
* Maintenance is scheduled to be completed as follows:
* 1A Containment Spray pump operable TODAY at 1500
* V1402, PORV operable TOMORROW at 0800
Which ONE of the following completes the statement below?
In accordance with ADM-09.22, Equipment Out of Service, an LCO action tracking entry ____(1)____ be omitted at the discretion of the SM or US for the 1A CS pump AND ____(2)____ be omitted at the discretion of the SM or US for V1402, PORV.
A.
(1) may
(2) may
B.
(1) may
(2) may NOT
C.
(1) may NOT
(2) may
D.
(1) may NOT
(2) may NOT

A

B.
(1) may
(2) may NOT

97
Q

Which ONE of the following completes the statements in accordance with OP-AA-1000, Conduct of Infrequently Performed Tests or Evolutions (IPTE)?
The same individual ____(1)____ perform the duties of the IPTE Manager AND Lead Test Coordinator?
The ____(2)____ gives the final permission to start the IPTE evolution.
A.
(1) can
(2) Shift Manager
B.
(1) can
(2) IPTE Manager
C.
(1) can NOT
(2) Shift Manager
D.
(1) can NOT
(2) IPTE Manager

A

C.
(1) can NOT
(2) Shift Manager

98
Q

Given the following conditions:
0000
Unit 1 commenced a 9 hour Containment Mini Purge IAW 1-NOP-25.02, Continuous Containment / Hydrogen Purge System
0800
1A gas decay tank release permit, is submitted for approval IAW 1-NOP-06.20, Controlled Batch Release to Atmosphere
Based on the conditions at time 0800, which ONE of the following completes the statements below?
The Containment Mini Purge is categorized as a ____(1)____ release.
The 1A decay tank release permit ____(2)____ be approved.
A.
(1) BATCH
(2) can
B.
(1) BATCH
(2) can NOT
C.
(1) CONTINUOUS
(2) can
D.
(1) CONTINUOUS
(2) can NOT

A

B.
(1) BATCH
(2) can NOT

99
Q

Given the following conditions:
* Unit 2 is experiencing a SGTR
* 2-EOP-04, SGTR is in progress
* Initial Cooldown for S/G isolation is in progress using SBCS
* AFAS-1 and AFAS-2 have actuated
* The STA has an active SRO license
Which ONE of the following completes the statements below?
IAW EPIP-02, Duties and Responsibilities of The Emergency Coordinator, a release ____(1)____ currently in progress.
IAW EPIP-02, If the SM becomes incapacitated during the event, the ____(2)____ is the NEXT designated position to assume the duties of the Emergency Coordinator (EC).
A.
(1) is
(2) Unit 2 Unit Supervisor
B.
(1) is
(2) Shift Technical Advisor
C.
(1) is NOT
(2) Unit 2 Unit Supervisor
D.
(1) is NOT
(2) Shift Technical Advisor

A

A.
(1) is
(2) Unit 2 Unit Supervisor

100
Q

Given the following conditions:
* Unit 1 is at 100% power
Subsequently:
* A Pressurizer Spray Valve fails OPEN
* The lowest Pressurizer Pressure observed was 1700 psia prior to event mitigation
Which ONE of the following completes the statements below?
In accordance with LI-AA-102-1001, Regulatory Reporting, the most LIMITING time this event requires a ____(1)____ report.
In accordance with EPIP-08, Off-Site Notifications And Protective Action Recommendations, the report to the NRC will be made via the ____(2)____ phone.
REFERENCE PROVIDED
A.
(1) 4 hour
(2) Hot Ring Down (HRD)
B.
(1) 4 hour
(2) Emergency Notification System (ENS)
C.
(1) 8 hour
(2) Hot Ring Down (HRD)
D.
(1) 8 hour
(2) Emergency Notification System (ENS)

A

B.
(1) 4 hour
(2) Emergency Notification System (ENS)