Green Bonnet Hydrant System Flashcards

1
Q

What are the two elevated areas in Hartford where fire suppression activities experience low water pressure and flow rates?

A

Prospect Hill and Avery Heights.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

MDC has installed a system that allows department apparatus to pump water into a ____ ________ hydrant to supplement the existing water main pressure and flow rates during fire suppression operations.

A

dry check-valved.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

All hydrants in the elevated areas served by the increased pressure from this green bonnet hydrant system have the hydrant bonnet painted what color?

A

Green.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

At the base level of each elevated area, MDC has installed a set of two hydrants positioned within ____ feet of each other at two separate locations.

A

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The yellow bonnet hydrant is a standard ____ ______ hydrant on a water main providing and except a minimum flow rate of ____ GPM.

A

Dry Barrel, 1000.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The green bonnet hydrant has a check-valve to allows water to be pumped into the hydrant and the interconnected water main, resulting in what?

A

Increasing water flow and pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

At each hydrant location is a storage cabinet secured with a cutaway lock containing what?

A

A 25ft 5in supply line with the couplings painted green to indicate use with the green bonnet hydrant, A mallet and a spare cutaway lock.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The first due engine shall proceed to the incident address. If the address is within ____ ft of the yellow bonnet hydrant, the company will utilize the ____ bonnet hydrant and lay a supply line to the incident address.

A

500, yellow.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The first due engine shall proceed to the incident address. If the address is further than ____ ft of the yellow bonnet hydrant, the company will utilize the ____ bonnet hydrant and lay a supply line to the incident address.

A

500, Green.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Be aware the flow rate and water pressure on hoselines and appliances will not be optimized until the ____ _____ hydrant system is operational.

A

Green bonnet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The _____ ____ to initiate the green bonnet hydrant system procedure shall be a primary consideration in implementing the IAP and associated tactics

A

Set-up time.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where should the second and third due engine proceed to once they arrive on scene?

A

To their designated Green bonnet hydrant system locations.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What must the Engine companies do in order to access the contents of the green bonnet hydrant system storage cabinet?

A

Cut the lock off the storage cabinet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Once the second and third due engines open the storage cabinet, they should attach one coupling of the ____ ft section of 5in supply line to the __ diameter discharge of the apparatus and the other coupling to the ____ on the green bonnet hydrant.

A

25, large, steamer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Once the second and third due engine hooks up the green bonnet hydrant to the discharge, what hydrant are they utilizing to connect to the intake on the pump?

A

The yellow bonnet hydrant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Once all the hydrants are hooked up and opened, what mode and PSI should the driver operate at?

A

Volume mode at no more than 110-115psi

17
Q

What will happen if you over pump the hydrant system?

A

It will activate the internal relief valve and decrease the flow rate and water pressure.

18
Q

Who has to get notified when the green bonnet hydrant system has been charged and is in operation?

A

IC

19
Q

Residual pressure may fall as low as ___ psi in order to generate the necessary water pressure and flow rated for fire suppression when employing the green bonnet hydrant system.

A

5

20
Q

At the conclusion of the incident, return all _____ to the green bonnet hydrant system storage cabinet and re-secure it with the enclosed _____ lock.

A

Materials, Cutaway

21
Q

After the incident, a department email should be sent to who, requesting the spare cutaway lock to be replaced?

A

FACT division

22
Q

Box number _____ at 705 New Britain Ave, Cottages requires the following assignment;
E9, E___, E10, T1, L2, L__, D1

A

4466, E15, L5

23
Q

Box number 4551 at 705 New Britain Ave, Avery Heights Convalescent Hospital requires the following assignment;
E__, E15, E10, T1, L2, L__, D1

A

E9, L5

24
Q

Box number _____ at 705 New Britain Ave, Avery Heights “The Heights Building” requires the following assignment;
E9, E5, E10, T1, L___, L___, D1

A

4553, L2, L6

25
Q

Box number _____ at 705 New Britain Ave, Avery Heights Nursing Home requires the following assignment;
E9, E15, E10, D1, L2, L__, D1

A

4556, L6

26
Q

Box number _____ at 705 New Britain Ave, Avery Heights Noble Building requires the following assignment;
E9, E15, E10, T1, L2, L__, D1

A

4557, L6

27
Q

Box number 4558 at 705 New Britain Ave, Avery Heights Nursing New Addition requires the following assignment;
E9, E15, E10, T1, L__, L___, D1

A

L2, L6

28
Q

What green bonnet hydrant does the second due engine take?

A

The green bonnet hydrant located on the west side of newington ave opposite Avery heights entrance. (North corner of newington ave and Waterford st)

29
Q

What green bonnet hydrant does the third due engine take?

A

The green bonnet hydrant located in front of 80 Haddam St opposite Storrs St.