Where can ventilation be secured from?
- Bridge (secures ventilation for whole boat)
- Galley (across from dry stores)
- MMR (inside vestibule)
- AMR (inside vestibule)
- EDG (right outside door)
What are the controlled spaces on the boat?
- Medical
- Ship’s Office
- Repair Lockers
- Morale Locker
- MAA Locker
- XO stateroom
- CO stateroom
- ESO Test Locker
What are the secured spaces on the boat?
- Armory
- Magazines
- Radio
What does the aft alarm panel in ECC indicate?
- Flooding
- High Temp
- Sprinkler
Where are the Reefer and Freezer alarm panels?
- Dry Stores - Main
- Mess Deck
- Outside Ship’s office
Where are the E-stops for the SSDG’s and Mains?
- Locally - black panel, red button
- Remotely - Bridge, port & starboard quarterdecks
- E-Pull station outside log office
- ECC - shutdown
- MPCMS
Where are the E-Pull stations located?
- Outside EDG in passageway
2. Outside Log office
What is KPAC?
It uses electrolysis to prevent rust from forming on the hull.
What is APC and where is it located?
Aqueous Potassium Carbonate System
- Sprinklers located in galley
- Activated when fusible link reaches 360 degrees or by pull station in passageway
- Ventilation button is located in passageway.
What spaces are batteries located?
EDG & ATON shop
What will happen in EDG and ATON shop if exhaust is secured?
Battery chargers and CO2 will shutdown
What type of batteries does ATON shop have?
It contains CO2 batteries and ATON batteries.
- CO2 batteries are 24 volt system
- ATON are 12 volt system
How many eye wash stations are there and where are they located?
5 installed:
- ATON shop
- Sick bay
- MMR
- AMR
- Paint Locker
5 portable
- Outside EDG
- Outside laundry
- Bow Thruster
- Stern Thruster
- Potable water Pump room
Where are the refrigerant leak detectors and indicators?
- Potable water equipment room
2. Lower AMR (mounted on sewage tank)
What are the three main pennants to know and what do they mean?
- Bravo - hoisted for anything flammable/HAZMAT
- Kilo - workers aloft
- Alpha - divers down
CO2 System - MMR
- Where located?
- Delay?
- Pull stations?
- Type of pull station?
- How many bottles?
- What will happen when these are activated?
- Located in SORS machinery room
- 60 second delay
- Pull Stations:
- In MMR vestibule
- In passageway across from dry stores
- On mess deck
- Double
- 12 bottles
- If activated it will secure machinery. To bypass activate valve in SORS machinery room prior to activating CO2.
CO2 System - AMR
- Where located
- Delay?
- Pull stations?
- Type of pull station?
- How many bottles?
- Located in Stern Thruster
- 60 second delay
- Pull Stations:
- AMR vestibule
- Above stern thruster hatch
- Double
- 6 bottles
CO2 System - EDG
- Where located
- Pull Stations
- Type of pull station?
- How many bottles
What needs to be secured?
- Bottles located behind hatch of ladder leading down to 6 man berthing
- 2 bottles
- 30 second delay
- Pull Stations
- Outside EDG, left of door
- In 4 man berthing passageway, on bulkhead
- Single
Emergency generator needs to be secured before CO2 discharge
CO2 System - Paint Locker
- Delay?
- Location
- How many bottles?
- Pull stations?
- What type of pull station?
- 30 second delay
- 1 bottle
- Bottle located in BOSN change room
- Pull Stations:
- BOSN change room
- Passageway outside DC shop and armory
- Single
What areas have installed CO2 systems?
- MMR
- AMR
- EDG
- Paint Locker
What are the 5 installed DC systems on the boat?
- Fire Main System
- Drainage System (educators)
- Aqueous Film-Forming Foam (AFFF)
- Carbon Dioxide System (CO2)
- Galley Hood System (APC)
Fire Pump Features:
- Motor?
- Horse power?
- PSI?
- Motor driven by 75 HP electric motor
2. Rated for 550 gallons per minute at 140 PSI.