General CDO Flashcards
Where can ventilation be secured from?
- Bridge (secures ventilation for whole boat)
- Galley (across from dry stores)
- MMR (inside vestibule)
- AMR (inside vestibule)
- EDG (right outside door)
What are the controlled spaces on the boat?
- Medical
- Ship’s Office
- Repair Lockers
- Morale Locker
- MAA Locker
- XO stateroom
- CO stateroom
- ESO Test Locker
What are the secured spaces on the boat?
- Armory
- Magazines
- Radio
What does the aft alarm panel in ECC indicate?
- Flooding
- High Temp
- Sprinkler
Where are the Reefer and Freezer alarm panels?
- Dry Stores - Main
- Mess Deck
- Outside Ship’s office
Where are the E-stops for the SSDG’s and Mains?
- Locally - black panel, red button
- Remotely - Bridge, port & starboard quarterdecks
- E-Pull station outside log office
- ECC - shutdown
- MPCMS
Where are the E-Pull stations located?
- Outside EDG in passageway
2. Outside Log office
What is KPAC?
It uses electrolysis to prevent rust from forming on the hull.
What is APC and where is it located?
Aqueous Potassium Carbonate System
- Sprinklers located in galley
- Activated when fusible link reaches 360 degrees or by pull station in passageway
- Ventilation button is located in passageway.
What spaces are batteries located?
EDG & ATON shop
What will happen in EDG and ATON shop if exhaust is secured?
Battery chargers and CO2 will shutdown
What type of batteries does ATON shop have?
It contains CO2 batteries and ATON batteries.
- CO2 batteries are 24 volt system
- ATON are 12 volt system
How many eye wash stations are there and where are they located?
5 installed:
- ATON shop
- Sick bay
- MMR
- AMR
- Paint Locker
5 portable
- Outside EDG
- Outside laundry
- Bow Thruster
- Stern Thruster
- Potable water Pump room
Where are the refrigerant leak detectors and indicators?
- Potable water equipment room
2. Lower AMR (mounted on sewage tank)
What are the three main pennants to know and what do they mean?
- Bravo - hoisted for anything flammable/HAZMAT
- Kilo - workers aloft
- Alpha - divers down
CO2 System - MMR
- Where located?
- Delay?
- Pull stations?
- Type of pull station?
- How many bottles?
- What will happen when these are activated?
- Located in SORS machinery room
- 60 second delay
- Pull Stations:
- In MMR vestibule
- In passageway across from dry stores
- On mess deck
- Double
- 12 bottles
- If activated it will secure machinery. To bypass activate valve in SORS machinery room prior to activating CO2.
CO2 System - AMR
- Where located
- Delay?
- Pull stations?
- Type of pull station?
- How many bottles?
- Located in Stern Thruster
- 60 second delay
- Pull Stations:
- AMR vestibule
- Above stern thruster hatch
- Double
- 6 bottles
CO2 System - EDG
- Where located
- Pull Stations
- Type of pull station?
- How many bottles
What needs to be secured?
- Bottles located behind hatch of ladder leading down to 6 man berthing
- 2 bottles
- 30 second delay
- Pull Stations
- Outside EDG, left of door
- In 4 man berthing passageway, on bulkhead
- Single
Emergency generator needs to be secured before CO2 discharge
CO2 System - Paint Locker
- Delay?
- Location
- How many bottles?
- Pull stations?
- What type of pull station?
- 30 second delay
- 1 bottle
- Bottle located in BOSN change room
- Pull Stations:
- BOSN change room
- Passageway outside DC shop and armory
- Single
What areas have installed CO2 systems?
- MMR
- AMR
- EDG
- Paint Locker
What are the 5 installed DC systems on the boat?
- Fire Main System
- Drainage System (educators)
- Aqueous Film-Forming Foam (AFFF)
- Carbon Dioxide System (CO2)
- Galley Hood System (APC)
Fire Pump Features:
- Motor?
- Horse power?
- PSI?
- Motor driven by 75 HP electric motor
2. Rated for 550 gallons per minute at 140 PSI.
Where is fire main pump #1 located?
MMR
Where is fire main pump #2 located?
AMR
Where is the fire main segregation valve for the forward fire pump located?
In mess deck area (1-66-0-L)
Where is the fire main pump segregation valve doe the aft fire pump?
Near the aft AFFF station (1-82-0-L)
In addition to the firefighting hose stations, the fire main also supplies water for:
- Seawater sprinkling system
- Dewatering eductors
- AFFF system
- Buoy deck wash down stations
- Tank full connections (ballast manifold)
- Emergency auxiliary seawater supply
How many firefighting hose stations are there?
32 hose stations
What type of fire hose do all machinery spaces have?
50ft of 1.5 inch hose
What type of fire hose do all spaces, other than machinery spaces, have?
100ft of 1.5 hose
What spaces use the Seawater Sprinkling System?
- Magazines
- SORS Cargo Hold
- Cargo Hold
Where are the sea water sprinkler system valves located for the magazines?
What is special about opening the sprinklers in this space?
Fire Main Valve - DC Repair Locker 2
- Turn Fire Main on on FWD AFFF control panel
- Fire Main Valve - Inside Repair Locker 2 (above door)
- Remote - Primary: Crane pedistal, right above magazines (between MAA locker and Pot. Water Pump room)
need CO’s permission to open
Where are the sea water sprinkler valves for cargo hold?
Turn on fire main from FWD AFFF control panel.
Fire Main Valve - DC Repair Locker 2 (above door)
Local - Inside Cargo hold
Remote - in Pway, above MAA locker on ceiling. Can be activated from the deck right above in Pway with stairs.
Where are the sea water sprinkler valves for SORS Cargo?
- Turn on fire main from AFT AFFF control panel
Fire Main Valve - outside dry stores
Local - SORS Machinery Room, center of forward bulkhead
Remote - STBD Pway of SORS cargo, aft bulkhead on wall just inside door (red handle).
What three installed drainage systems allow the boat to dewater spaces?
- Main Drainage System
- Independent Drainage Systems
- Oily Water Collection System
Does the oily water system use eductors?
No. It collects oily bilge water in a tank for processing.
How eductors work? What should you never do when operating eductors?
- Fire main provides water flow through the eductor creating a low pressure vacuum effect. This draws the surrounding water out through the eductor into the overboard discharge piping system.
- Never operate in a closed space with personnel inside because the negative pressure could possibly over power their lungs causing asphyxiation.
What spaces does main drainage provide dewatering services for?
MMR Bilge
AMR Bilge
Dewater Ballast Tank
Where is the eductor for the forward drainage system located?
Potable Water Pump Room
Where is the eductor located for the aft drainage system?
Stern Thruster
What spaces does the aft drainage system dewater?
Stern Thruster
What are the proper steps to operating the drainage system?
- Turn on fire pump
- Open the overboard discharge
- Open the fire main supply valve to the eductor.
- Open the suction valves to the space to be dewatered.
What is the AFFF system made up of?
- 2 Fixed Stations
- Bilge and overhead sprinkling nozzles
- AFFF hose stations
How much do each of the fixed AFFF tanks hold?
Forward AFFF - 40 gallons
AFT AFFF - 75 gallons
What do the lights on the CO2 alarm indicators mean?
- White power light indicates power is available to the system.
- Red pre-discharge light flashes when the CO2 system has been activated.
- Red discharge light flashes when CO2 starts flooding the compartment.
Where are the CO2 alarm indicators located for EDG
- Right outside the door to EDG
2. Outside door to AMR (left of door)
Where are the CO2 alarm indicating panels for AMR?
- Inside AMR vestibule
- On bulkhead next to 4 man center berthing
- Above Stern Thruster hatch
Where are the CO2 alarm indicating panels located for MMR?
- Inside MMR vestibule
- In Pway across from dry stores
- On mess deck, on bulkhead right of first class lounge
What are the two types of pull boxes for the CO2 system?
- Single
- Double
What are the two things released with a couple CO2 pull?
- Cylinder Release - activates CO2 system
- Valve Release - actually discharges the system into the space.
If the CO2 system extinguishes the fire, how long must the fire team wait to enter the space?
15 minutes and must enter space with SCBA’s.
What are the primary portable DC equipment on board?
- PKP (potassium bicarbonate) extinguisher
- CO2 extinguisher
- Portable pumps
- DC supplies
How many PKP extinguishers are on board?
How much do they weigh?
Range?
- 35qty of 18lbs. Located throughout berthing and office areas, with two at the entrance of any space that could have a class B fire.
- 4qty of 27lb. Located one each in AMR, MMR, Bow thruster and Stern thruster.
In what 5 spaces are the eyewash stations hard piped?
AMR MMR Aton Shop Medical Paint Locker
Where are the 5 plastic eyewash stations located?
Stern Thruster Bow Thruster Potable Water Pump Room Outside EDG Outside Laundry
What is the crane whip rated for?
10,000 pounds
What is the crane main rated for?
40,000 pounds