What are the trips for the RWCU pumps?

A

CLAMS

C - Cooling water high temp 195 degF
L - Low suction flow < 70 gpm, 15 sec TD
A - Any suction valve not full open
M - MPD
S - SLC handswitch initiation A&B
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

when will the F035 (blowdown to RW) Auto close?

A

high level in Aux Bldg Eq Drain tank level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

when can the F035 (blowdown to RW) be reopened after an auto closure?

A

After signal clears

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the purposes of RWCU?

A

minimizes heat transfer surface functions

limits rad levels

discharges excess rx water to either the hotwell, or to RW

Prevents thermal stratification with no recirc pumps running

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What should be done immediately after RWCU pump trips?

A

Isolate RWCU blowdown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What group 8 isolations can be bypassed?

A

Differential flow high 79 gpm for 45 seconds

All room temps: MSL tunnel temp, RWCU pump/valve/hx rooms

Loss of LDS logic control power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What pre-pump AND post-pump modes of RWCU

A

Pre-pump < 100 psig RX pressure, pumps before Hx

Post-pump >100 psig RX pressure, Hx before pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the power supplies for RWCU?

A

11/12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

why is pre-pump used when < 100 psig?

A

Ensure NPSH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

what percent must BWRT be to perform backwash?

A

<48%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What level trips backwash transfer pump?

A

2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

when do RWCU holding pumps start?

A

162 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

what are the div 1 and 2 group isolation valves?

A

Div 1 - outboards: 250, 253

Div 2 - Inboards: 251, 252

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is temp maintained at for demin inlet?

Why?

A

130 deg F.

140 deg F, Resin breaks down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What flow can you have with 1 pump and no filters?

A

300 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

what flow can you have with 2 pumps and no filters?

A

300-500 gpm

17
Q

What are group 6 isolation signals?

A

Rx level -41.6”

DW pressure 1.23 psig

18
Q

What are the group 8 isolation signals?

A

M - Manual isolation initiation
S - SLC actuation
T - Steam tunnel hi temp 185 deg F (E31)
Ex area temps: (E31)
Pump 170 deg f
Valve 135 deg f
HX 120 deg f
D - diff flow hi 79 gpm for 45 seconds (E31)
L - Low reactor water level -41.6”
L - Loss of LDS control power to LDS logic (E31)
N - Non Regen outlet temp (FD inlet temp) high 140 F

19
Q

how long after RWCU pump trip can it be restarted if a FD was in service?

A

2 minutes after flow has stopped

20
Q

how many pumps can be in service if suction is from bottom head only?

A

1

21
Q

how long can a test/normal switch be left in test?

A

8 hours

22
Q

why should the F046 or F041 AND F035 not be opened at the same time during blowdown

A

vacuum will be lost to radwaste

23
Q

what is RWCU blowdown used for? and where does it go to?

A

used for startup to reject water due to 60 gpm entering reactor from CRD with no steam exiting.
reject to hotwell or aux bldg eq drain (hotwell is preferred)

24
Q

where can RWCU blow down to after group 6 isolation?

A

radwaste

25
Q

where can RWCU blow down go to after Aux bldg isolation?

A

Radwaste or main condenser

26
Q

how many RWCU pumps should be used when > 100 but < 200 psig Rx pressure?

A

one

27
Q

Why should pre-pump not be used >100 psig Rx pressure?

A

so you don’t exceed 200 deg F on ctmt penetrations 87 and 88

28
Q

when will the G36 -F003 Auto close on a Filter demin fault?

A

Hi Filter Demin Differential pressure 30 psid

Effluent post-strainer hi Diff pressure 10 psid

FD outlet flowlow of 36 gpm (20%)

Mode switch in filter with 80 second TD

29
Q

When will the G33-F033 close? (blowdown FCV)

A

Upstream flow controller <5 psi

Downstream controller > 140 psig and > 5% output