E22 - HPCS Flashcards

1
Q

What flow does the restricting orifices restrict flow to?

A

9100 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How long after initiation should HPCS be injecting?

A

32 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Does HPCS Jockey pump ever auto stop?

A

NO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What happens on initiation? (sequence of events)

A
  1. F001 (CST suction) opens IF F015 (SP suction) is NOT full open.
  2. F004 OPENS (inj valve)
  3. F010 & F011 CLOSE (test return to CST)
  4. F023 CLOSES (test return to SP)
  5. Pump starts
  6. Diesel starts
  7. SSW C and Room cooler start 10 seconds later
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Purpose of HPCS?

A

Designed to mitigate the effects of Post Loca

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

normal suction source of HPCS?

A

CST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where does HPCS test return back to?

A

Either CST or Supp pool, depending on the suction source

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the pump trips?

A

time overcurrent
instant overcurrent
underfrequency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

HPCS logic can be reset with what signal still in?

A

High drywell pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the initiation signals for HPCS?

A
  • 41.6” Rx level

1. 39 DW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Whats the power supply for HPCS

A

17AC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What suppression pool level is required for HPCS to be operable?

A

14’6”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Will HPCS lose its logic if power is lost?

Will you lose overrides?

A

NO!

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When will F001 (CST suction) Auto close?

A

If F015 (supp pool suction) is full open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

what must level be at to reset the low level logic?

A

Above -41.6”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When can hi drywell pressure be reset?

A

whenever bro

17
Q

What happens if level drops below +53.5” and hi level initiation is reset?

A

injection valve comes back open if low level has not been reset

18
Q

When will the min flow valve open?

A

< 1206 gpm AND > 130 psig

19
Q

When will the min flow valve close?

A

> 1206 gpm OR < 130 psig

20
Q

when does the pump suction from suppression pool open?

A

< 5’ CST or > 18’9” in suppression pool

21
Q

what pressure is HPCS able to inject into Rx?

A

1177 psid

22
Q

What flow rate is it injected at? High and low?

A

550 gpm

7115 is rated flow @ > 445 psid

23
Q

when will HPCS isolate from the Rx?

When will it re-open isolation valve?

A

53.5” Rx water level

When high level signal is reset or -41.6” Rx water level