Fuel System Non Normals Flashcards
Fuel imbalance
Eg left more than right Will be displayed on EICAS AMBER FUEL IMBALANCE MSG AMBER POINTER to tank/value with less fuel Operate cross feed pump Turn off lower quantity tanks fuel pumps
Left tank now feeding both engines
Monitor until imbalance correct
Amber msg blanks
Fuel balance flashes for a few seconds
Fuel auto jettison EICAS msg
Auto fuel jettison shutoff is inop
Jettison continues to standpipe unless stopped by crew
Fuel jettison sys msg
Fuel jettison system has failed
Fuel jettison main msg
Main tank jettison system is failed
Jettison from main tank is stopped
There are no consequences for center tank jettison
Fuel jettison nozzle
Respective jettison valve failed closed or open
If closed, jettison possible through other nozzle, fuel imbalance may occur
If open unitended jettison may occur
Fuel press eng
Respective engine uses suction feed
Crossfeed may be necessary to prevent thrust decay
Fuel qty low
Fuel qty low in either main tank
Crossfeed to prevent flameout
Fuel pump center l
Respective pump switch is on with an empty tank or pump failed
Use crossfeed to prevent imbalance if center tank has fuel
Fuel in center
Center tank pumps off with still significant amount of fuel in tank
Fuel valve APU
APU fuel valve disagrees with commanded position