Fuel System Flashcards

1
Q

.What happens when all the fuel in an auxiliary tank is pumped to the main tank and consumed?

A

AUX pump will automatically turn off and supply CAAS with an advisory for the associated tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What keeps fuel loss and post-crash fires to a minimum by breaking or shearing at predetermined locations and sealing themselves to retain fuel?

A

Breakaway self sealing fittings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is installed in each tank to prevent fuel spillage from the vents should the helicopter roll over following a crash landing?

A

Roll-over Vent System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How is an Engine Fuel Valve opened or closed electronically?

A

Fire Pull Handles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

If the engines are running, CAAS will activate a FUEL LVL caution at ______pounds in the event the fuel quantity low level warning system has failed (internal fuel tank sensors).

A

<360 lbs for more than 2 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

ENG 1/2 FUEL PRESS LO caution(s) activate when fuel pressure in the respective line is below what?

A

10 psi +/- 1 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The fuel flow display on the fuel page of the MFD will flash when fuel flow is equal to or greater than ___________ pounds.

A

2,995 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the purpose of the jet pump system within each main fuel tank?

A

To remove the fuel from the cross over line and inner-tank manifolds after single point pressure refueling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How is the jet pump system activated?

A

By turning on the respective main tank pumps on the overhead sw panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What two fuel system related switches are monitored by the Cockpit Voice and Flight Data Recorder (CVFDR) for position?

A

X-FEED and Main Fuel Pump sw’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What should be avoided if both boost pumps should fail in either main fuel tank with the XFEED open and a low fuel indication?

A

Nose low attitude in excess of 5 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the max capacity for fuel in the CH47F?

A

6,887.6 lbs
1028 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If an aux fuel pump fails during normal flight, will that fuel still be usable

A

No. It becomes unusable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where does the APU get its fuel

A

left main fuel tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where does the heater get its fuel

A

right main fuel tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Engine fuel valves and XFEED valves can be operated _____ or ______

A

electrically or mechanically

17
Q

What happens when all the fuel in an auxiliary tank is pumped to the main tank and consumed?

A

AUX pump will automatically turn off and supply CAAS with an advisory for the associated tank

18
Q

How is an engine fuel valve closed or opened manually

A

a lever on the valve

19
Q

Can fuel be transferred between tanks through the XFEED system

A

No. XFEED system feeds engines directly

20
Q

3 conditions that cause the engine or XFEED fuel valve warning lights to illuminate

A
  1. During normal operations (open to close, close to open, fire pull handle)
  2. When a short circuit occurs
  3. When the valve protection relay fails
21
Q

How is the Fuel Screen pages accessed on the MFD

A

T6 key when on INST

22
Q

During pressure refueling, the max fueling rate is ____ gallons per minute at ____ psi

A

300
55 psi

23
Q

how is electrical power supplied to the refuel station

A

via the refuel station switch on the Fuel Control Panel on the Overhead Switch Panel

24
Q

If a REFUEL VALVE POSN indicating light remains illuminated when power is removed from the refuel station during rapid refuel operations, what will be the mission status of the fuel in the associated Aft AUX fuel tank?

A

Unusable