FLIGHT RECORDER Flashcards
1
Q
FLIGHT RECORDER TEST SWITCH
- 2 POSITION -
A
- Flight data recorder: AC & DC powered
-
NORMAL:
- guarded position
- IN FLIGHT: operates anytime electrical power is available
- GROUND: operates anytime electrical power is available AND either engine must also be operating
-
TEST:
- powers the flight recorder on the ground
- OFF light SHOULD go out
2
Q
OFF LIGHT
A
-
Illuminated (AMBER):
- indicates FDR is NOT operating OR the test is invalid
- may indicate:
- power failure
- loss of input data
- electronic malfunction
- this light will initially be ON until engine start - after ‘soft click’ is heard the light should go out
- on shutdown of the SECOND ENGINE you can hear the same ‘soft click’ (at approx 18 psi oil pressure)