CREW & PAX OXYGEN PANEL Flashcards
1
Q
CREW OXYGEN Press Indicator
A
- indicates pressure at the crew oxygen cylinder
- O2 gauge is ELECTRICAL (BAT BUS with the BAT SWITCH ON)
- when there is high pressure (> 2600 psi) a green disk breaks (external on aircraft)
2
Q
PASS OXY ON Light
A
- Illuminated (Amber): pax oxygen system is operating and masks have dropped
- MC & OVERHEAD annunciators
- also means PAX O2 system activated manually or automatically to drop the masks
[1sp - pull the mask to initiate air flow - O2 at the PSU for pax is a 50/50 mix - 50% Oxygen 50% ambient air]
3
Q
PASSENGER OXYGEN SWITCH (PASS OXYGEN)
- 2 positions -
NORMAL
ON
A
- NORMAL: (guarded)
- pax masks drop and O2 system activated automatically if CABIN ALT climbs to 14,000’
- ON:
- activates system manually and drops masks if auto function fails.