Fire safety Flashcards
Any material capable of being easily ignited, burning intensely, or having a
rapid rate of flame spread.
Flammable
Liquids having a flash
point below 140°F and a vapor pressure not
exceeding 40 pounds per square inch.
Flammable liquids
means any liquid having a
flash point at or above 140 deg. F and below
200 deg. F
Combustible liquid
An approved, closed container,
of not more than 5 gallon capacity, having a
flash arresting screen, spring closing lid, and
spout cover designed so it will safely relieve
internal pressure when exposed to fire.
safety can
The employer must develop a ____ to be followed
through construction, and provide all
equipment as required for firefighting.
fire protection program
A temporary or permanent water supply of sufficient volume, duration and pressure must be made available as soon as _____.
combustible materials accumulate
Where _____ are to be provided, they must be installed and
available as soon as practical.
Underground water mains
In all structures where \_\_\_ are required, they must be maintained as construction progresses in such a manner that they are always ready for fire protection use.
standpipes
Standpipes must be provided with _____ on the outside of the structure, at the street level,
and conspicuously marked.
Siamese fire department connections
Fire Cutoffs (Walls & Doors) three requirements
1. Fire walls and exit stairways must be given
construction priority.
2. Fire doors must be hung on openings as soon
as practical.
3. Fire cutoffs must be retained in buildings
undergoing alterations or demolition until
operations require their removal.
Fire walls and exit stairways must be given ___________.
.
construction priority
____ must be hung on openings as soon
as practical.
Fire doors
Fire cutoffs must be retained in buildings
undergoing alterations or demolition until _____.
operations require their removal.
Portable Firefighting Equipment four rules.
- 1 2A extinguisher for every 3000 sq. ft. of
floor space - Travel distance not to exceed 100 feet
- 1 per floor
- 1 by each stairwell
1 2A extinguisher for every ___ of
floor space
3000 sq. ft.
The travel distance for a 2a extinguisher should not exceed ____.
100 feet
How many 2a extinguishers should there be per floor?
one
How many 2a extinguishers should be by each stairway?
one
Alternatives to 2A fire extinguishers
- A 55 gallon drum of water with two fire pails.
- ½ inch garden hose not longer than 100 feet with nozzle capable of discharging 5 gallons per minute.
- Hoses must be located on racks or reels.
A 10B extinguisher must be within ___ of 5 gallons of flammable liquid or gas.
50 feet
Extinguishers must be inspected and maintained per ___.
NFPA
Fire extinguisher classification D
Combustible metals
Fire extinguisher classification A
Wood, Paper, Trash
Fire extinguisher classification C
Electrical equipment
Fire Extinguisher classification B
Flammable liquids
Portable extinguishers are rated for the___of fire they can handle.
size
This rating is a number from ____ for Class A fires and ____ for Class B fires.
1 to 40
1 to 640
The larger the ____, the larger the fire the extinguisher can put out.
Number
They use monoammonium phosphate which is a dry chemical that is able to put out the fire. This extinguisher is able to put out three classifications of fires. Type A, B, C.
ABC extinguisher
They can be put in both class B and C fires caused by flammable liquids (B) and energized electrical equipment (C) .
BC fire extinguishers
What does PASS stand for?
- Pull 2. Aim 3. Squeeze 4. Sweep
During demolition or alteration, sprinklers must be retained in service ________.
as long as reasonable
New construction utilizing automatic sprinklers must follow the work and be placed in ___________.
as soon as practical
An ______ must be established by the employer that alerts employees and the fire department.
alarm system
Alarm system =
telephone, siren, radios, air horns, etc.
Alarm system must be posted at ____ and ____.
Phones, job entrances
Three fire prevention techniques
- Electrical wiring and equipment for light, heat, and power must be installed per Subpart K.
- Gas powered equipment must point exhaust away from combustible materials.
- Smoking must be prohibited in work areas which may pose a fire hazard.
Electrical wiring and equipment for light, heat, and power must be installed per ____.
Subpart K
Gas powered equipment must point exhaust away from____.
Combustible materials