FIRE PROTECTION SYSTEMS Flashcards
Where are carbon monoxide detectors normally used?
In aircraft cabins and cockpits.
What are indications of excess carbon monoxide fumes when using CO testes?
Changes color due to a chemical reaction to gray or black. Sophisticated detectors provide a digital output in parts per
million of carbon monoxide present or illuminate a light and/or an audible alarm sounds.
What does a thermal switch fire detection system consist of?
Heat-sensitive units that complete electrical circuit at certain temperatures and trigger a warning.
How are thermal switch units wired?
Parallel with each other and in series with the light
How is a thermocouple fire warning system different from a thermal switch system?
Thermal – Works at a specific temperature whereas
Thermocouple - depends on a rate of temperature rise.
How are FENWAL sensing elements wired?
In series to a control unit.
How are the detector units in a double-loop FENWAL system wired?
In PARALLEL between two complete loops of wiring.
Describe a continuous loop detection system*.
One or more wires imbedded in a special ceramic core that changes its resistance with a change in temperature.
How does a light refraction type (photoelectric)Smoke detector warn of possible fire?
Smoke particles in the air will cause the photoelectric cell to conduct eletricity and trigger the alarm
How may a photoelectric smoke detector be checked?
Using a switch in the test circuit.
Name two types of smoke detection instruments used in aircraft.
Light refraction and Ionization.
What are two types of installed fire extinguishing systems?
CO2 and Halogenated Hydrocarbons.
What protection is provided for a fire extinguisher bottle in case of a temperature rise in excess of
set limits?
The agent dumps overboard ejecting a red thermal discharge indicator disk.
What type extinguishing agente is usually found in a high-rate-of-discharge system?
Halogenated hydrocarbon type agentes (halon)
What procedure is used to check a fire extinguisher container for pressure?
A chart must be used for determining minimum and maximum gauge Reading based on temperature.