What happens when FIRE WARNING TEST is connducted using BATTERY POWER only
All indications will be the same except F/O MASTER WARNING LIGHT will not illuminate and the cyan PODS TEST PASS alert message on EAD will not illuminate
If APU FIRE WARNING TEST is conducted on battery power what must be accomplished after start
Test must be accomplished again to make sure everything is working properly
What indications do you get on a engine fire (5)
- L/R ENG FIRE hanlde light illuminates
- FUEL switch light illuminates
- Aural/Vocal warning sounds
- ENGINE L/R alerts on EAD
MASTER WARNING lights flash
What indications do you get on APU FIRE (5)
- APU FIRE alert on EAD
- APU automatically shuts down
- MASTER WARNING lights flash
- FIRE light on external APU ground control panel illuminates
- Aural/Vocal warnings sound (Flight Deck-3 cycles, and horn will continue until fire is extinguished)
CARGO SMOKE or FIRE Indications (8)
- MASTER WARING lights
- MASTER CAUTION lights
- CARGO SMOKE voice warning from CAWS
- CARGO SMOKE FWD OR AFT level 3 EAD and AIR SD
- Land at nearest suitable airport - displayed on consequence page
- DISCHARGE CARGO AGENT - Displayed on EAD and AIR SD
- AIR SD will display RED triangles
- AFT/FWD CARGO SMOKE AGENT DISH switchlight will flash “PUSH”
What happens aprox after 1 min of the cargo bottle discharged
The amber AFT/FWD CARGO SMOKE AGENT DISCH “PUSH” switchlight will extinguish and be replaced by an amber “LOW” light indicating the first halon bottle has discharged. A CARGO AGENT 1 LO alert will also be displayed on the EAD.
What happens approximately 6 mins after the CARGO AGENT is blown
similar alerts will direct the second Halon Bottle into the appropriate cargo compartment. The second bottle discharges at a slower rate. CARGO AGENT 2 LO alert will illuminate after 2 hours
How do you know if the cargo smoke agent is discharged
Red triangles displayed on the AIR synoptic are cargo smoke detectors
LAVATORY FIRE indications (3)
- MASTER CAUTION lights Illuminate
- LAVATORY SMOKE alert on EAD
- HI-LO chime on the PA
Engine/APU LOOP switch operation on the AFT overhead panel
BOTH
A/B
BOTH - (Normal Position) - minimizes false warnings since both loops have detect a fire or overheat position before activating a fire warning
A/B - Used for dispatch if one fire loop is inoperative. Fire warning will still occur is a fire is detected in the selected loop.
What does the fire detection system consist of……..
Two independent, heat-sensitive detector loops located in each engine and the APU. Each loop provides both fire and overheat detection.
Engine Fire Extinguishing Controls and Indications FIRE TEST AGENT 1/2 LOW FAULT TEST ENGINE FIRE HANDLE
FIRE TEST - Test both A and B loops
AGENT 1/2 LOW - Illuminated - Respective agent has been discharged
FAULT TEST - Maintenance use only
ENGINE FIRE HANDLE - light illuminated associated engine fire is detected or test in progress
What happens when you pull the ENGINE FIRE HANDLE
PULL (FULLY EXTENDED) - Shuts off associated engine….
FUEL
HYDRAULIC
GENERATOR
AURAL/VOCAL warning if the master caution lights havent been pushed
APU FIRE EXTINGUISHING Controls and Indications….
APU FIRE Light
AGENT 1/2 LOW Light
APU SHUT OFF Switch
FIRE AGENT DISCHARGE 1/2 switch
APU FIRE Light - Illuminated if a fire is detected
AGENT 1/2 LOW Light - illuminated if the respective agent is discharged
APU SHUT OFF Switch - NORM for normal operations, SHUT OFF -shuts down APU and arms extinguishers
FIRE AGENT DISCHARGE 1/2 switch - Normal - Guarded switch, normal position. DISCHARGE - DISCHARGES RESPECTIVE AGENT INTO APU compartment.
SWITCH POSITIONS
APU FIRE CONT Switch Norm and off
APU FIRE AGENT Switch (NO 1/NO 2) off and disch
APU FIRE CONT Switch
NORM - Normal Position
OFF and AGENT ARM - Immediately shuts down APU and arms extinguishers
APU FIRE AGENT SWITCH (NO 1/NO 2)
OFF - Normal Position
DISCH 0 Discharges selected agent into APU compartment
Cargo smoke detection system switches
CARGO SMOKE FWD/AFT SWITCH (2)
SINGLE
NORM
AFT/FWD CARGO SMOKE AGENT DISCH switchlight (4) PUSH LOW
CARGO SMOKE FWD/AFT SWITCH (2)
SINGLE- Selects single smoke detection system
NORM- Selects normal dual smoke detection system
AFT/FWD CARGO SMOKE AGENT DISCH switchlight (4) PUSH - Flashes Amber to indicate fire/smoke detected. Push to discharge bottle, changes light from flashing to steady. Extinguishes when low Light illuminates LOW- Illuminates when amber after agent discharged. Push again to extinguish
What does the CARGO SMOKE TEST BUTTON DO and when can you perform after adding power
Test the system
Disabled for 6 mins after establishing power
What does the ENG and APU fire extinguishing system consist of….
2 fire extinguisher agent containers and associated AGENT LOW lights
How is the ENG and APU fire agents distributed…..
Each fire bottle has seperate discharge heads and distribution lines to each engine and the APU
How is a cargo fire detected…..
Multiple photoelectric smoke detectors mounted in recessed pans in each cargo compartment ceiling
How is a fire supressed in the cargo compartment…..
Two Halon fire extinguishing agent bottle connected to both and aft cargo compartments
How long can fire be suppressed in the cargo comparment…..
80 minutes
What happens if the CARGO SMOKE DET SYS is selected to single
A single postion CARGO SMOKE DET SYS panel will allow one detector to activate the alarm