FFP - Brownstones Flashcards
In brownstone buildings, what is the first floor known as?
The basement.
Which description concerning a “Deadman” room is inaccurate?
It is located on the lower floors.
The following terms accurately describe a “Deadman’s” room.
a) small bedroom
b) only entrance is from the hall
c) may be found in the front or rear of the building
The following accurately describe the rear extensions on Brownstones.
a) They are added on the first floor
b) Maybe two to three stories in height
c) 10-20 feet in depth
d) Have their own cockloft
In brownstone buildings, what is the second floor referred to?
The parlor floor.
How big is the cockloft in a brownstone with a flat roof?
The cockloft space is approximately 2’-3’ in height.
Describe roof construction in a brownstone.
a) In flat roof buildings, the pitch is towards the rear
b) The majority are flat roof with NO PARAPET in the rear
c) Some have have more floors and a higher roof in the REAR than in the front.
d) Some have a center peak
How can fire extend in a brownstone?
Via the cornice.
A medium fire situation may be extinguished how?
A medium fire situation may be extinguished with two (2) handlines.
What must the officer of the first ladder company do PRIOR to ordering any horizontal ventilation?
He must evaluate the impact on interior conditions.
When is a member under the “Immediate” supervision of an officer?
They are under the “Immediate” supervision of an officer when
a) they are within sight or hearing of their officer
b) they are working off of a hoseline or searchline.
Which member has the discretion of selecting the tools deemed necessary to complete his/her assignment while operating at a brownstone fire?
The ladder company chauffeur.
For a TOP FLOOR fire in a BS, with NO LIFE HAZARD showing, where should the officer of the 1st arriving ladder company (r/m apparatus) direct the LCC to initially raise and position the aerial?
To the roof of the exposure.
In addition to taking his H/T and flashlight, what tools does the 1st arriving OVM (r/m app.) for a TOP floor fire in a BS?
The Halligan tool and saw.
The roofman will cut the roof
A 10’ scissor ladder when used at a BS fire will permit?
a) The access to the roof of a one story setback
b) Access to the second floor for VEIS
c) Access to the third floor from the roof of the setback for ventilation
d) Provide a means of climbing fences.
What is the correct order of preference for the 1st arriving roof F/F (r/m app) to access the roof of a BS?
1) Aerial ladder
2) 2nd Aerial ladder
3) Adjoining building
* If T/L 1st due, then first choice is the T/L basket.*