Members entering building should be equipped with ?
PPE and SCBA
Trucks brings their tools and engines bring FE tools into lobby
Note: at this time engines DON’T bring roll ups
At a single unit response for class E or J alarm, the officer should enter the building with who?
All FFs except chauffeur
Officer then gets building personnel to do what?
Reset the alarm.
If the alarm does reset, the officer shall wait how long to see if it holds ?
2-3 minutes
If alarm doesn’t hold or reactivates what does officer do?
Leave one ff in lobby take elevator if above 7th floor. Leave one ff with elevator
Upon any indication of smoke or heat do what?
Contact ff in lobby or chauffeur in rig and transmit box or 10-76
After asking for more help officer does what?
Return to lobby with FFs and secure hose and check alarm panel again. Recall elevators
After getting hose, does engine await truck or go solo?
Unless undue delay in the arrival of additional units, the engine shall wait in lobby for truck
What if truck finds smoke, do they return to lobby?
No because they have their tools. Return elevator with ff to lobby to transport incoming members to the upper floors