Ext Insulation EIFS with drainage Flashcards
Backer rod = foam rod fit to joint size + 25% to 30% and is compressed into joint to limit sealant
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 3 Sec 3.3
Drainage Medium = material, space or plane that creates means to drain water to exterior
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 3 Sec 3.8
Initial Grab = refers to how well wet state material remains in place after application
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 4 Sec 3.22
6 locations where EIFS expansion joints are required
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 5 Sec 4.2
Materials must be supplied in original, unopened, undamaged regulatory compliant packaging
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 5 Sec 5.1
Minimum product storage temperature is 40 degrees
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
Pg 5 Sec 5.3
EIFS Samples - contractor provides to owner/architect (size ample to show color and texture)
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 6 Sec 8.4.1
Cold weather conditions exist when below 40 degrees
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 6 Sec 9.1
Adhesive - compatible with all materials in EIFS (insulation, substrate, mesh); Portland cement types I
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 7 Sec 12.1
Mechanical fasteners - made from corrosion resistant materials (pull-out, tensile & shear) to resist wind load
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 7 SEc 12.10
Substrate Temperature minimum 40-degrees (Application) + 24-hours afterward
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 12 Sec 14.2.2
Fastener Penetrations not less than 3/8” in steel, 3/4” in wood, and 1” in masonry
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 13 Sec 14.3.4(b)4
Insulation board installed in running board pattern with 6” overlap - butted firmly (with <1/16th inch gap)
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 14 Sec 14.3.5(d) & (e)
Mesh must extend at least 2.5” beyond edges of inside corners
ANSI/EMIA Standard for exterior Insulation and finish systems (EIFS) with drainage
PG 15 Sec 14.3.6 (c)