Evvolution 34 KO Curtain Deployment Flashcards
In what situations shall the KO Curtain be deployed ?
- Window in fire apartment has failed and size up indicates wind is blowing into apartment continuously or intermittently
- Size- up indicates that deployment of KO curtain prior to window failure will prevent wind driven fire from developing
Who can order the deployment of the KO curtain?
Only when ordered by IC.
What will be the effects of us ing the KO CURTAIN.
Immediate 50% decrease in temp
Significant flame reduction
Increase in smoke production
The deployment ff on the floor above should remove the window so he can have better access to deploy KO curtain
No don’t break or remove window unless absolutely necessary
Once the KO curtain is deployed the chance of auto exposure is reduced because window is now covered
False you can expect the fire to vent and auto expose the deployment window through the space between KO curtain and the building wall
The deployment ff must have his full ppe donned and face piece in the stand bye position when deploying the KO curtain just in case conditions change on the floor above?
False deployment ff must have face piece on and ppe donned
When deploying KO curtain the IC must have a spotter to watch and coordinate deployment?
Not a must depending on conditions encounterd
Where does the spotter get the binocular that will be needed?
From the battalion vehicle
Where will the spotter position himself ?
To see target window
Position will enable spotter to Confirm that the deployment and receiving ff are in position at correct windows
Once deployed ensure it is in proper position
Observe effects of ko curtain on vent profile and report results to IC
Who decides which window the KO curtain will be deployed from
The deployment ff
Who will coordinate the deployment of the KO curtain?
The 1st arriving ladder company officer on the fire floor
Who decides when the deployment of the KO curtain is ready and when should this be done
The deployment ff after both the deployment and receiving ff are in position at there respective windows
This is only up to point they are in Position then the ladder company officer In fire apt coordinates
After KO curtain is in position the ropes should be secured by Tying off
False do not tie off
How shall the ropes secured while KO curtain is being deployed out window
Place hand holding ropes under sill of window and lock rope with hand against wall
The ropes of the KO curtain should be throw so the KO curtain clears any obstructions below
No they should not drop ropes not throw