Evolution 32 Emergency LSR ops Flashcards
What conditions will cause the emergency LSR operation to be implemented citywide?
When a large number of personal harness and/ or PSS are OOS
This evolution will only be implemented by command chief it will transmitted via?
- 65-2 message
- ATSP
- Department radio
- MDT
In non- fireproof buildings when the emergency LSR op is implemented when should 1st and 2nd due roof man LSR to roof ?
Buildings 3 stories in height or greater
Additional all fire-proof residential structures bring LSR
What does the first due roof man do when the emergency LSR op is implemented ?
Carry LSR to their position then perform assigned duties on arrival at roof or floor above in fireproof residential
What does 2nd due roof do when the emergency LSR op is implemented?
- Carry LSR to there position
- Immediately after reaching position ID possible substantial objects for tying off
- Position LSR at that location for possible use
- Position 1st due LSR at substantial object ( use different substantial object if possible )
- Then perform assigned duties on roof or floor above
When setting up LSR for possible deployment second due roof should remove LSR form bag in preparation of use?
No it shall not be removed
When the emergency LSR is implemented roof FF’s shall maintain there position on roof or floor above until when
IC declares “ probably will hold”
IC declares to evacuate roof
IC declares that there services are no longer needed on roof
What shall IC due when roof members leave there positions on roof or floor above when emergency LSR op is implemented
IC announce over HT that roof team no longer in place
IC ensures that duties previously performed by roof FFs are assigned to other members
What is the preferred method of removing a member wearing a personnel harness when emergency LSR op is implemented ?
For them to remove themselves via single slide utilizing LSR that has been deployed from above
What is preferred method of removing members not wearing personnel harness when emergency LSR op is implemented ?
Two roof firefighters to perform lowering member with LSR or rescue pick up
If a member becomes distressed and may be needed to be rescued when the emergency LSR op is implemented what actions should he take
Transmit mayday
Id unit and position
Specify location for rope deployment
While awaiting LSR form above fully clear the window of all obstructions