ESWS DC&ENGINEERING Flashcards
How many AFFF stations are there?
20
What is the capacity of the AFFF tanks at the stations?
600 gallons
What is the ratio of AFFF concentrate to water?
94% water to 6% AFFF concentrate
What is the capacity of the two AFFF fill tanks in the hangar bay?
3900 gallons
How many repair lockers are there?
10
How many unit lockers are there?
28
Which repair lockers are on the 2nd deck and where are they located?
Rep. 2, Fwd Port Supply male berthing
Rep. 3, Aft Port Reactor lounge
Rep. 4, Fwd Port Medical P-Way
Rep. 5, Midship aft mess decks
Which repair lockers are on the main deck and where are they located?
1A Hangar Bay 3, Std side by trash room 1B Hangar Bay 2 Port side 1F Hangar Bay 1 Port side
Which repair lockers are on the 03 level and where are they located?
7A Aft Std side
7B Midship Std side
7F Fwd port side
What sizes of SCBA bottles do we have onboard?
⁃ 30 minute
⁃ 45 minute
What’s the minimum PSI an SCBA bottle can be in order to use it in a casualty?
4000psi
What locker positions use the 30 minute bottle?
- Investigators,
- repair electrician,
- boundary man outside the primary smoke boundary.
What locker positions use 45 minute bottles?
Attack team
What type of agent is used to combat a class ‘A’ fire?
Water, CO2, AFFF
What type of agent is used to combat a class ‘B’ fire?
AFFF, PKP, HFP, APC
What type of agent is used to combat a class ‘C’ fire?
CO2
What method is used to extinguish a class ‘D’ fire?
Jettison
Who is the Damage Control Officer?
Chief Engineer, CHENG, CDR Machart
How do you operate a PKP bottle?
⁃ Break the tamper seal
⁃ Pull the pin
⁃ Activate the CO2 cartage
⁃ Spray in a sweep motion
How many size PKP bottles do we carry onboard?
2
What are the two sizes of the PKP bottles?
18lbs and 27lbs
How far does the 18lb PKP bottle discharge?
19ft
How far does the 27lb PKP bottle discharge?
21ft
How do you operate a CO2 bottle?
⁃ Break the tamper seal
⁃ Pull the pin
⁃ Ground the bottle
⁃ Hold the horn by the handle
⁃ Squeeze lever
How far does a CO2 bottle discharge?
4-6ft from the end of the horn
What is the Box Fan rated at?
3200 CFM
What is the RAM Fan rated at?
2000 CFM
What types of dewatering equipment we use onboard?
⁃ S-type eductor
⁃ Peri-Jet Eductor
⁃ ESP
⁃ Buckets and swabs.
What powers the P-100 pump?
JP-5
What powers the ESP?
440V
What types of pipe patches do we use onboard?
⁃ Soft Patch
⁃ Jubilee
⁃ EWARP
⁃ Banding
What does EWARP stand for?
Emergency Water Activated Repair Patch
What is the Max PSI for the Soft Patch?
150psi
What is the Max PSI for the Jubilee Patch?
Upwards of 100psi
What is the Max PSI for the EWARP?
150psi
Who serves as the ITT Leader and DCTT Team Leader?
XO
Identify the following hand wheel color codes:
- Steam- White
- Potable Water - Dark Blue
- Sea water - Dark Green
- Sewage - Gold
- JP-5 - Purple
- Fire main - RED
Name three types of shore:
H, I, K
Which shore is the strongest?
I
Why is “I” type shoring the strongest?
It applies direct pressure
What are the two sizes of vari nozzle?
⁃ 1-1/2 (95gpm)
⁃ 2-1/2 (125gpm)
What size vari nozzle is used inside the skin of the ship?
1-1/2 (95gpm)
What is the required manning for 1-1/2inch fire hose?
3-5 personnel
What is the required manning for 2-1/2 fire hose?
5-7 personnel
How many Battle Dressing Stations (BDS) do we have? Name them:
(6)
- Forward BDS
- Amidship (Main) BDS
- Aft BDS
- Fwd Aux BDS
- Aft Aux BDS
- Flight Deck BDS
How many positions in the repair party? Name them:
(11)
- Repair Party Leader
- Team Leader
- Investigator
- Nozzleman
- Plugman
- Scene Leader
- Phone Talker
- Electrician
Hoseman
Accessman
Overhaulman
What is indicated by the following colored piping systems?
- Yellow - Gasoline
- Purple - JP-5
- Light Green - Oxygen
- Dark Purple - Refrigerant
What are the basic material conditions of readiness?
⁃ X-ray
⁃ Yoke
⁃ Zebra
What are the special classifications of material conditions?
⁃ Circle X-ray
⁃ Circle Zebra
- Circle Yoke
- William
⁃ Dog Zebra
⁃ Circle William
What type of Firemain System do we have onboard?
Composite system of two (2) 12 inch mains
How many Motor Driven Fire Pumps do we have onboard?
26
What is their capacity?
1000gpm
What fixed system is used for combating Bravo fires in the galley?
APC/ Gaylord system