EQUIPMENT COOLING Flashcards

1
Q

Equipment cooling provides cooling air for what compartment/systems?

A
  • Flight deck equipment
  • Electrical and equipment racks (E & E)

Note:FCOM, VOL 2; 2.20.16

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When is warm exhaust air ducted overboard through the ground exhaust valve?

A
  • Engines not operating
  • Equipment cooling selector in NORM
  • Ambient temperature moderate or high

Note:FCOM, VOL 2; 2.20.16; 2.20.17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When does the equipment cooling system configure for flight?

A

• One or more engines on each wing is operating.

Note:FCOM, VOL 2; 2.20.17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How can you manually configure the equipment cooling system for flight?

A

• Positioning the Equipment Cooling Selector to STBY.

Note:FCOM, VOL 2; 2.20.17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which valve is closed when equipment cooling is in closed loop mode?

A

• Inboard exhaust valve

Note:FCOM, VOL 2; 2.20.17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the source of equipment cooling air for the flight deck electrical equipment?

A

• With two or three packs operating, the flight deck equipment cooling source valve directs conditioned air into the flight deck electrical equipment.

Note:FCOM, VOL 2; 2.20.17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Describe the operation of the equipment cooling system with the Equipment Cooling Selector in OVRD.

A
  • Provides equipment cooling in flight if internal fans are inoperative.
  • Internal fans are not powered.
  • Smoke/override valve opens.
  • All other valves closed, no air flow to forward cargo.
  • Cabin differential pressure draws air from the panels area on the flight deck, through the equipment cooling ducts to the E&E, to create a reverse flow of air across the equipment, then through the supply duct, then overboard.

Note:FCOM, VOL 2; 2.20.17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Under what conditions would the equipment cooling system revert to closed loop mode?

A
  • LLCCAFR Selector in FWD LOW, BOTH LOW, FWD HIGH, with a forward lobe temp selector set lower than 10C (50F).
  • If a single internal fan fails.
  • When the MAIN CARGO FIRE ARM switch is pushed.

Note:FCOM, VOL 2; 2.20.17; 8.10.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly