APU Flashcards

1
Q

What are the start sources for the APU, and which one do we normally use?

A
  • TR (Transformer-Rectifier Unit), when Utility Bus 4 is powered.
  • APU Battery, when Utility Bus 4 is unpowered.

Note:FCOM, VOL 2; 7.14.2; 7.30.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Can the APU be operated in flight?

A

• Yes, when left running for takeoff it can be operated in flight up to 20,000 feet

Note:FCOM, VOL 2; 7.30.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Is electrical power available from the APU in flight? How about APU bleed air in flight?

A
  • No, APU electrical power is not available in flight
  • Yes, APU bleed air is available in flight for one pack up to 15,000 feet

Note:FCOM, VOL 2; 7.30.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What APU components are powered by the APU battery bus and APU Hott battery bus?

A

C-F-F-I: Control the fuel fire in the door

  • Inlet door
  • APU controller
  • DC fuel pump
  • APU fire detection system

Note:FCOM, VOL 2; 7.30.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What APU components are powered by the main battery and main hot battery bus?

A

F-F-S: Fuel Fire Standby

  • APU fire extinguisher
  • APU fuel valve
  • Standby power for the APU controller

Note:FCOM, VOL 2; 7.30.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What powers the APU starter during a battery start sequence?

A
  • The APU battery
  • (All other APU components are powered by the main battery while the APU starter is engaged)

Note:FCOM, VOL 2; 7.30.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What happens if the TR should overheat with the start source in TR?

A
  • Start power is transferred to the battery
  • Further start attempts with an overheated TR are inhibited

Note:FCOM, VOL 2; 7.30.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How does a TR failure affect APU starting?

A

• Automatic switching to the APU battery is not provided
• Moving the start switch to BATTERY removes the TR from the starting
circuit and allows APU starting on battery power.

Note:FCOM, VOL 2; 7.30.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When does the EICAS memo message APU RUNNING display?

A

• When the APU selector is ON and APU N1 RPM exceeds 95% N1.

Note:FCOM, VOL 2; 7.30.1; 7.40.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Describe the APU shutdown sequence.

A
  • Rotating the APU selector to OFF begins the shutdown cycle
  • APU bleed air valve closes
  • APU continues running unloaded for a 60-second cooldown period.
  • When the cooldown period finishes, the APU shuts down.

Note:FCOM, VOL 2; 7.30.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What would happen if the battery switch is positioned OFF prior to completion of the APU shutdown cooldown period?

A

• The APU shuts down immediately.

Note:FCOM, VOL 2; 7.30.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How long should you wait before turning the battery switch OFF after the APU selector is rotated to OFF, and why?

A
  • 2 minutes
  • Allows a complete shutdown sequence, with fire detection capability.

Note:FCOM, VOL 2; 7.30.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What would cause the APU to shut down immediately?

A
  • A limit is exceeded
  • A fire is detected
  • Battery switch turned off during APU shutdown sequence.

Note:FCOM, VOL 2; 7.30.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly