Engine Start Flashcards
Abort for
Place START SWITCH to ABORT
IGNITION light does not illuminate with Nh stabilized around 25% and voltmeter indicating 400A
T6 does not rise in 10 seconds after condition lever placed in FEATHER
Abnormal T6 rise or T6 exceeding limits
Oil Pressure not rising with Nh at 45% or higher
Ignition light does not extinguish after 50% Nh (56% maximum)
Abnormal smoke or flames coming out of the engine exhaust pipe
Any unusual vibration or noise
Abnormal parameters are showing on the gages
IGNITION light does not illuminate
Indication that backup battery is OFF or inoperative
Will hear aural warning channel
If T6 is less then 160°C
Advance condition levers to FEATHER as Nh accelerates through 10%
If T6 is above then 160°C
Advance condition levers to FEATHER between 10% and 20%
If engine fail to light up within 10 seconds after placing condition levers in FEATER
ABORT the start and preform dry motoring before attempting restart
Minimum oil temperature required to unfeather the propeller
0°C
Action and indication in EEC manual reversion
If EEC manual reversion happen Nh will not reach 60%, move condition levers to MIN RPM and reset EEC
When starting the second engine with battery and MAIN GEN/APU GEN
Advance operating engine above GROUND IDLE before starting second engine to avoid EEC manual reversion
If manual reversion happens reset EEC after second engine start
Delay engine start until generator load is below 150A
With EEC ON increased torque is normal
When started form GPU
PWR selector to BATT after engine start
If engine start was aborted due to HOT or HUNG start or NO LIGHT
Do not move starter switch to ABORT until starter limit has expired