Emergency Procedure Flashcards
ENGINE TROUBLESHOOT
Fuel Selector - switch tanks
Fuel Pump - Off
Magnetos - cycle
Carb heat - Off
Mixture - Full Rich
Throttle - Adjust
Engine Instruments - Check
- if engine does not restart -> SECURE ENGINE
SECURE ENGINE
Fuel Selector - Off
Battey Master - Off
Alternator - Off
Fuel Pump - Off
Magnetos - Off
Carb Heat - Off
Mixture - Idle Cut off
Throttle - Closed
Seatbelts - Secure
SPIN RECOVERY
PARERS
Power Idle
Aileron neutrual
Rudder opposite
Elevator fwd
Rudder neutral when spin stops
Smoothly recover
ENGINE FIRE DURING FLIGHT
Mixture - idle cut off
Throttle - closed
Fuel Selector - Off
Fuel Pump - Off
Heater/Defroster - Off
if fire extinguishes - SECURE ENGINE
if fire persists - EMERGENCY DESCENT
ENGINE FIRE DURING START
Starter - continue cranking
Mixture - Idle cut ff
Throttle - open
Fuel Pump - Off
Fuel Selector - Off
Abandan AC if fire persists
ELECTRICAL FIRE
Battery Master - Off
Alternator - Off
Vents - On
Heater - Off
Extinguish fire if persists
If power is required, isolate faulty system as per POH
EMERGENCY DESCENT
Throttles - IDLE
descend at 125KIAS at 30-45AOB
LOSS OF OIL PRESSURE
land as soon as practical
prepare for power off landing
HIGH OIL TEMPERATURE
land as soon as practical
prepare for power-off landing
VACUUM FAILURE
Vacumn Gauge - check
Gyro Instruments - identify
Auxiliary Pump - On
declare ATC emergency
land as soon as practical
ALTERNATOR FAILTURE
ALT light illuminuated
Check Anmeter
If 0,
Alternator - Off
Circuit breaker - Check and reset
Alternator - On
if ALT light continues
Alternator - off
Electrical loads - reduce
land as soon as practical
ELECTRICAL OVERLOAD
Anmeter oer 20amps
Alternator - on
battery master - off
if loads are reduced:
electrical loads - reduce to min
if loads are not reduced
Alternator - off
Battery master - as required
land as soon as practical