EMB7 Fire Protection Flashcards
How many detector loops are there in the engine?
2
What happens when a engine fire is detected? (4)
Aural warning
Lights- fire handle and master warning
EICAS- fire warning light in respective ITT INDICATOR
EICAS warning msg ENG 1/2 fire is displayed
What happens when a engine fire is detected (4)
Aural warning
Lights- fire handle and master warning
EICAS- fire warning light in respective ITT INDICATOR
EICAS warning msg ENG 1/2 fire is displayed
What happens when you pull the fire handle ?(3)
Closes Engine fuel shutoff valve Engine hydraulic shutoff valve Engine bleed shutoff valve
How many fire extinguishing bottles are there?
- A and B
How do you discharge bottle A?
Pull fire handle and rotate counter clockwise
How do you discharge bottle B?
Pull fire handle and rotate clockwise
Describe APU fire protection system
Provides fire detection Extinguishing And continuous built in test
How is APU fire system powered detection/extinguishing?
Detection
MSU 1 ( DC ESS bus 1) and MAU3 ( DC ESS bus 2)
Extinguishing
DC ESS bus 2
How many detection loops in the APU?
2
What happens when you push the APU fire extinguisher button?
Discharges APU bottle
APU FADEC shuts down APU
Closes the APU fuel feed shutoff
Displayed EICAS MSG - APU fired btl disch
Will APU auto shutdown on ground because of fire?
Yes after 10 seconds
How many smoke detectors in forward cargo?
3
How many smoke detectors in aft cargo?
2
What happens with a cargo smoke indication?
All.
Aural warning
Lights- Master warning Associated cargo extinguishing compartment button illuminates
EICAS CRG AFT SMOKE CRG FWD SMOKE
Appropriate bottle is armed
If forward compartment —
air circulation fan turns off and forward ventilation outflow valve closes
How is the engine fire system powered?
Detection and Extinguishing
Detection- MAU1( DC ESS bus 1) And MAU3(DC ESS bus 2)
Extinguishing- hot batt bus 1 and 2