Electrical Flashcards
When will the battery charger operate
- BATT switch ON
- EMER PWR switch is OFF
- Ground service bus is powered
Normal AC power voltage and frequency for the engine driven generators
Voltage - 115 +/-3 V
Frequency - 400 +/-4 Hz
Identify the location and function of the ground service switch
MD88
MD90
MD88:
The APU PWR switch and EXT PWR switch, both located on the overhead panel, remove and select their respective power to the ground service bus
MD90
1. Ground service power switch located on the overhead panel performs the following functions:
A. OFF - disconnects APU or external power from the AC tie bus to the ground service bus
B. ON - connects APU or external power from the AC tie bus to the ground service bus provided the right generator bus is not powered. APU Power has priority over external power for powering the ground service bus
What are the essential electrical equipment that may be powered during a complete loss of normal electrical power when positioning the EMER PWR switch ON or ARM(90)
- Captains PFD, ND, Airspeed, altimeter, TA/VSI
- # 1 VHF COM/NAV
- Interphone
- PA
- FGCP course/heading bugs(displayed on ND)
- APU and Eng. fire detection/protection
- Capt/FO/Cockpit flood lights
- Cockpit thunderstorm lights
On the MD90 how long must you wait before starting APU and why
90 seconds
This allows the EPCU built in test to finish and prevents an ELEC SYS BIT FAIL message on the OAP which requires maint action to clear
How do you connect the APU generator to the electrical system?
What values do you check first
88
90
BOTH - check voltage and frequency: 115 +/-3 V, 396+/-8 Hz(ground) 400 +/-10(air)
MD88:
Placing the L/R APU BUS switch to ON selects APU Power to the respective buses. they are left in the ON position in flight unless a non-normal checklist calls for them to be off
MD90:
APU GEN switch is normally left on to supply power to the respective generator bus provided all protection circuits are satisfied and generator is operating
Explain the meaning of each blue light on the electrical panel MD88 APU PWR AVAIL EXT PWR AVAIL PWR IN USE
MD90
EXT PWR AVAIL
APU PWR AVAIL
MD88
- APU PWR AVAIL light - indicates APU generator power is available
- EXT PWR AVAIL light- external power available
- POWER IN USE light - selected power source is connected to respective bus
MD90
- EXT PWR AVAIL light - external power switch is ON and frequency and voltage in limits
- APU PWR AVAIL - APU generator is ON and freq and volts within limits
Where do you read voltage frequency and amps
The AC VOLTS meter, FREQUENCY meter, and AC LOAD meter, located on the electrical power panel of the forward overhead panel
D.C. Volts, amps and loads are adjacent to the AC indicators
List the components powered by the ground service bus
The ground service bus provides power to only those circuits necessary for ground servicing
How long will be batteries last on emergency power
MD88
MD90
MD88: both AC and D.C. Emergency power when the EMER PWR switch is ON for approximately 30 minutes
MD90: with EMER PWR switch IN or ARM, both AC and DC power for 45 minutes
Recall the function of the A/C BUS X TIE switch
OPEN
AUTO
OPEN - opens AC crosstie relay, isolates left and right generator busses, prevents closing of relay
AUTO - The AC crosstie relay will operate automatically
What are the 3 functions of the AC crosstie relay
- Prevents paralleling
- Powers on powered generator bus
- Isolates generator plus faults
Under certain fault conditions AC crosstie relay will lock open
What’s the function of the BUS TIE switches on the MD90
OPEN
AUTO
OPEN - isolates the L/R generator bus from the tie bus
AUTO - (Normal position)Electrical Power Control Unit(EPCU) automatically opens and closes bus Tie relays as required to maintain electrical power to respective busses
What’s the function of the D.C. BUS TIE switch
CLOSE
OPEN
CLOSE - closes DC cross tie relay and connects the left and right DC buses. supplies DC power from one side to the other in case both transformer rectifiers fail on either the left or right system
OPEN - (normal position) left and right DC buses are isolated
Explain the function of the BATT switch
OFF
ON
OFF - remove batteries from battery bus, battery charger and DC transfer bus
ON - Connects battery direct bus to battery bus.
Select some batteries to battery charger and DC transfer bus
White line, position horizontally, indicates locked